123 resultados para fatigue cracking


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The premature failure of steam turbine rotor blades, manufactured in forged 12% Cr-NiMoV martensitic stainless steel, was investigated using visual inspection non-destructive testing, macro and microfractography, microstructural characterization, EDS microanalysis, chemical analysis, micro hardness and tensile testing. The blades belonged to the last stage of a thermoelectric plant steam turbine generator (140 MV A). The results indicated that the failure of the blades was promoted by foreign-particle erosion, which attacked preferentially the low-pressure side of the lower trailing edge of the blades. The resulting wear grooves acted as stress raisers and promoted the nucleation of fatigue cracks, which probably grew during the transition events of the steam turbine operation. Finally, water drop erosion was observed on the blade upper leading edge (low-pressure side). (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coaracy Nunes was the first hydroelectric power plant in the Amazon region, being located in Araguari River, Amapa State, Brazil. The plant operates since 1976, presenting now a nominal capacity of 78 MW. The shear pins, which are installed in the turbine hydraulic arms to control the wicket gate and regulate the water flow into the turbine blades, suffered several breakdowns since 2004. These shear pins are made of an ASTM 410 stainless steel and were designed to break by a shear overload of 120 kN. Fractographic investigation of the pins, however, revealed two types of fracture topographies: a region of stable crack propagation area, with non-pronounced striation and secondary cracks; and a region of unstable propagation, featuring elongated dimples. These results indicated that the stable crack propagation occurred by fatigue (bidirectional bending), which was nucleated at machining marks under high nominal load. Finite element analysis was carried out using two loading conditions (pure shear and a combination of shear and bending) and the results indicated that the presence of a bending stress strongly increased the stress concentration factor (85% rise in the shear stress and 130% rise in the Von Mises stress). Misalignment during shear pins assembly associated with vibration might have promoted the premature failure of the shear by bending fatigue. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The premature failure of a horizontal heat-exchanger, which occurred after service exposure at 580 degrees C for 50,000 h, revealed the occurrence of extensive through-thickness cracking in approximately 40% of the tube/stationary tube-sheet welds. Additionally, the internal surface of the welded joint featured intensive secondary intergranular cracking (up to 250 mu m deep), preferential formation of a 150 mu m thick layer of (Fe, Cr)(3)O-4 and internal intergranular oxidation (40 mu m deep). The welded region also showed intense carbon pick-up and, as consequence, severe precipitation of intergranular M7C3 and M23C6 carbides. The fracture surface was composed of two distinct regions: a ""planar"" region of 250 mu m, formed due to the stable crack growth along by the intergranular oxidation; and a slant region with radial marks, formed by the fast crack growth along the network of intergranular carbides. The association of intergranular oxidation pre-cracks with microstructural embrittlement promoted the premature failure, which took place by an overload mechanism, probably due to the jamming of the floating tube-sheet during the maintenance halt (cooling operation). (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fatigue behavior of the SAE 1045 steel in four different conditions is reported in this paper. Four treatments were tested: polished surface, corrosive atmosphere (sugar cane juice), low quality roughness (typical equivalent surface of the shaft cane mill) and the combined condition of the two last treatments involved. Fatigue tests were performed in rotating bending conditions and the values of fatigue strength for the different situations from tests were obtained. The diminution in fatigue strength for the synergy condition of rough surface and corrosive atmosphere was of 8.7%, result statistically representative with less than 0.01% of uncertainty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work investigates the effects of photodegradation on the environmental stress cracking resistance of polycarbonate (PC). Injection molded samples were exposed to the ultraviolet (UV) light for various times in the laboratory prior to solvent contact. The bars were then stressed with two different loads in a tensile testing machine under the presence of ethanol. During this period, the stress relaxation was monitored and, after unloading, the ultimate properties were evaluated. Complementary tests were done by size exclusion chromatography, UV-visible spectroscopy, scanning electron microscopy, and light microscopy. The results indicated that ethanol causes significant modification in PC, with extensive surface crazing as well as reduction in mechanical properties. The previous degraded samples showed a higher level of stress relaxation and a greater loss in tensile strength in comparison with the undegraded ones. The synergist action of photodegradation and stress cracking in PC may be a consequence of the chemical changes caused by oxidation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Viroids have been used as ""graft transmissible dwarfing agents"" (GTDA) in several countries, mainly to reduce growth of citrus trees, thus increasing their density in orchards. In the State of Sao Paulo, Brazil, plants of the acid lime `Tahiti` are usually grafted with a complex of GTDA, presumably viroids. The aim of the present work was the identification and molecular characterization of the viroids infecting trees of acid lime `Tahiti` displaying ""Quebra galho"" (bark-cracking). Viroids were identified and characterized by biological indexing in `Etrog` citron, Northern-blot hybridization, RT-PCR, cloning and complete sequencing of the RNA genomes. Citrus exocortis viroid (CEVd), Hop stunt viroid (HSVd) and Citrus dwarfing viroid (CDVd) were found in different combinations. Although we have not been able to infer a direct relationship between the agronomical performance and symptom severity with the presence of a specific viroid or viroid combination, the differences in the severity of ""Quebra-galho"" symptoms among different trees is probably associated with the presence (or absence) of CEVd, with its interaction with other viroids perhaps determining the different phenotypes observed in the field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of the present study was to review a group of patients with meniscal injuries resulting from structural failure unrelated to trauma or degenerative problems to which was given the name ""meniscal injury due to fatigue"". Material and Method: Evaluations were made on 140 patients with meniscal injuries without any apparent cause, who were therefore considered to have meniscal injuries due to fatigue. Among these, 85 patients were male and 55 were female. The medial meniscus was the most affected site (92% of the cases). Results: All these injuries were diagnosed by means of clinical examination and magnetic resonance imaging. The patients underwent meniscectomy by means of arthroscopy and the results were divided into two types: good and poor. Poor results were found in 27% of the cases, among which nine patients progressed to idiopathic osteonecrosis. Conclusion: We conclude that injuries due to fatigue must be assessed as injuries caused by failure and, therefore, constituting a syndromic pathological condition that may progress to idiopathic osteonecrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Although fatigue is a ubiquitous symptom across countries, clinical descriptions of chronic fatigue syndrome have arisen from a limited number of high-income countries. This might reflect differences in true prevalence or clinical recognition influenced by sociocultural factors. Aims To compare the prevalence, physician recognition and diagnosis of chronic fatigue syndrome in London and Sao Paulo. Method Primary care patients in London (n=2459) and Sao Paulo n=3914) were surveyed for the prevalence of chronic fatigue syndrome. Medical records were reviewed for the physician recognition and diagnosis. Results The prevalence of chronic fatigue syndrome according to Centers for Disease Control 1994 criteria was comparable in Britain and Brazil, 2.1% v. 1.6% (P=0.20). Medical records review identified 11 diagnosed cases of chronic fatigue syndrome in Britain, but none in Brazil (P<0.001). Conclusions The primary care prevalence of chronic fatigue syndrome was similar in two Culturally and economically distinct nations. However, doctors are unlikely to recognise and label chronic fatigue syndrome as a discrete disorder in Brazil. The recognition of this illness rather than the illness itself may be culturally induced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: While in many Western affluent countries there is widespread awareness of chronic fatigue syndrome (CFS), also known as myalgic encephalomyelitis (ME), little is known about the awareness of CFS/ME in low- and middle-income countries. We compared the awareness of CFS in Brazil and the United Kingdom. Methods: Recognition and knowledge of CFS were assessed among 120 Brazilian specialist doctors in two major university hospitals using a typical case vignette of CFS. We also surveyed 3914 and 2435 consecutive attenders in Brazilian and British primary care clinics, respectively, concerning their awareness of CFS. Results: When given a typical case vignette of CFS, only 30.8% [95% confidence interval (CI), 22.7-39.9%] of Brazilian specialist doctors mentioned chronic fatigue or CFS as a possible diagnosis, a proportion substantially lower than that observed in Western affluent countries. Similarly, only 16.2% (95% CI, 15.1-17.4%) of Brazilian primary care attenders were aware of CFS, in contrast to 55.1% (95% CI, 53.1-57.1%) of their British counterparts (P <.001). This difference remained highly significant after controlling for patients` sociodemographic and socioeconomic characteristics (P <.001). Conclusions: The awareness of CFS was substantially lower in Brazil than the United Kingdom. The observed difference may influence patients` help-seeking behavior and both doctors` and patients` beliefs and attitudes in relation to fatigue-related syndromes. Attempts to promote the awareness of CFS should be considered in Brazil, but careful plans are required to ensure the delivery of sound evidence-based information. (c) 2008 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We aimed to quantify fatigue frequency and evolution in amyotrophic lateral sclerosis (ALS), and to correlate fatigue with factors such as age, sex, educational level, disease duration, functionality, quality of life, dyspnoea, depression and sleepiness. Sixty ALS patients (test group: TG) selected by El Escorial criteria and 60 normal individuals (control group: CG) matched according to sex and age, were followed every three months, during 9 months, by means of self-report scales: Fatigue Assessment Instrument (Fatigue Severity Scale plus three qualitative subscales); ALS Functional Rating Scale; McGill Quality of Life Questionnaire; dyspnoea analogical scale; Beck Depression Inventory and Epworth Sleepiness Scale. Fatigue was reported by 83% of TG (median: 3.6, interquartile range 1.5-5.4), compared with 20% of CG (median: 1, 1 - 1), and was significantly greater in the TG (p < 0.001, Mann-Whitney test). Fatigue severity increased by the ninth month of the study (p=0.0008, Friedman, Muller-Dunn post test). There was no correlation between fatigue and other parameters, except for an inverse correlation with age at disease onset (p=0.0395, Spearman rank correlation). In conclusion, fatigue was frequent in ALS, greater in the youngest patients and worsened during follow-up. Possibly, ALS related fatigue is an independent factor, which deserves individualized approach and treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments submitted to nitrogen ion implantation by using a custom-made cyclic fatigue testing apparatus. Methods: Thirty K3 files, size #25, taper 0.04, were divided into 3 experimental groups as follows: group A, 12 files exposed to nitrogen ion implantation at a dose of 2.5 x 10(17) ions/cm(2), accelerating voltage of 200 kV, currents of 1 mu A/cm(2), 130 degrees C temperature, and vacuum conditions of 10 x 10(-6) torr for 6 hours; group B, 12 nonimplanted files; and group C, 6 files submitted to thermal annealing for 6 hours at 130 degrees C. One extra file was used for process control. All files were submitted to a cyclic fatigue test that was performed with an apparatus that allowed the instruments to rotate freely, simulating rotary instrumentation of a curved canal (40-degree, 5-mm radius curve). An electric motor handpiece was used with a contra-angle of 16:1 at an operating speed of 300 rpm and a torque of 2 N-cm. Time to failure was recorded with a stopwatch in seconds and subsequently converted to number of cycles to fracture. Data were analyzed with the Student t test (P < .05). Results: Ion-implanted instruments reached significantly higher cycle numbers before fracture (mean, 510 cycles) when compared with annealed (mean, 428 cycles) and nonimplanted files (mean, 381 cycles). Conclusions: Our results showed that nitrogen ion implantation improves cyclic fatigue resistance in rotary nickel-titanium instruments. Industrial implementation. of this surface modification technique would produce rotary nickel-titanium instruments with a longer working life. (J Endod 2010;36:1183-1186)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (yttria-tetragonal zirconia polycrystals [Y-TZP]) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus palladium-silver alloy (PdAg) three-unit bridges. Materials and Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n = 21 each), were fabricated, veneered, cemented (n = 3 each), and Hertzian contact-tested to obtain ultimate failure load. In each framework group, 18 specimens were distributed across three step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (two-sided at 90% confidence intervals) for a ""mission"" of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft, Tucson, AZ, USA). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusions: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300 N. Failure modes differed between materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of framework design on the fatigue life and failure modes of metal ceramic (MC, Ni-Cr alloy core, VMK 95 porcelain veneer), glass-infiltrated alumina (ICA, In-Ceram Alumina/VM7), and veneered yttria-stabilized tetragonal zirconia polycrystals (Y-TZP, IPSe.max ZirCAD/IPS e.max,) crowns. Methods: Sixty composite resin tooth replicas of a prepared maxillary first molar were produced to receive crowns systems of a standard (MCs, ICAs, and Y-TZPs, n = 10 each) or a modified framework design (MCm, ICAm, and Y-TZPm, n = 10 each). Fatigue loading was delivered with a spherical steel indenter (3.18 mm radius) on the center of the occlusal surface using r-ratio fatigue (30-300 N) until completion of 10(6) cycles or failure. Fatigue was interrupted every 125,000 cycles for damage evaluation. Weibull distribution fits and contour plots were used for examining differences between groups. Failure mode was evaluated by light polarized and SEM microscopy. Results: Weibull analysis showed the highest fatigue life for MC crowns regardless of framework design. No significant difference (confidence bound overlaps) was observed between ICA and Y-TZP with or without framework design modification. Y-TZPm crowns presented fatigue life in the range of MC crowns. No porcelain veneer fracture was observed in the MC groups, whereas ICAs presented bulk fracture and ICAm failed mainly through the veneer. Y-TZP crowns failed through chipping within the veneer, without core fractures. Conclusions: Framework design modification did not improve the fatigue life of the crown systems investigated. Y-TZPm crowns showed comparable fatigue life to MC groups. Failure mode varied according to crown system. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this research was to evaluate the fatigue behavior and reliability of monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate and hand-layer-veneered zirconia all-ceramic crowns. Materials and Methods: A CAD-based mandibular molar crown preparation, fabricated using rapid prototyping, served as the master die. Fully anatomically shaped monolithic lithium disilicate crowns (IPS e.max CAD, n = 19) and hand-layer-veneered zirconia-based crowns (IPS e.max ZirCAD/Ceram, n = 21) were designed and milled using a CAD/CAM system. Crowns were cemented on aged dentinlike composite dies with resin cement. Crowns were exposed to mouth-motion fatigue by sliding a WC-indenter (r = 3.18 mm) 0.7 mm lingually down the distobuccal cusp using three different step-stress profiles until failure occurred. Failure was designated as a large chip or fracture through the crown. If no failures occurred at high loads (> 900 N), the test method was changed to staircase r ratio fatigue. Stress level probability curves and reliability were calculated. Results: Hand-layer-veneered zirconia crowns revealed veneer chipping and had a reliability of < 0.01 (0.03 to 0.00, two-sided 90% confidence bounds) for a mission of 100,000 cycles and a 200-N load. None of the fully anatomically shaped CAD/CAM-fabricated monolithic lithium disilicate crowns failed during step-stress mouth-motion fatigue (180,000 cycles, 900 N). CAD/CAM lithium disilicate crowns also survived r ratio fatigue (1,000,000 cycles, 100 to 1,000 N). There appears to be a threshold for damage/bulk fracture for the lithium disilicate ceramic in the range of 1,100 to 1,200 N. Conclusion: Based on present fatigue findings, the application of CAD/CAM lithium disilicate ceramic in a monolithic/fully anatomical configuration resulted in fatigue-resistant crowns, whereas hand-layer-veneered zirconia crowns revealed a high susceptibility to mouth-motion cyclic loading with early veneer failures. Int J Prosthodont 2010; 23: 434-442.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the stress levels at the core layer and the veneer layer of zirconia crowns (comprising an alternative core design vs. a standard core design) under mechanical/thermal simulation, and subjected simulated models to laboratory mouth-motion fatigue. The dimensions of a mandibular first molar were imported into computer-aided design (CAD) software and a tooth preparation was modeled. A crown was designed using the space between the original tooth and the prepared tooth. The alternative core presented an additional lingual shoulder that lowered the veneer bulk of the cusps. Finite element analyses evaluated the residual maximum principal stresses fields at the core and veneer of both designs under loading and when cooled from 900 degrees C to 25 degrees C. Crowns were fabricated and mouth-motion fatigued, generating master Weibull curves and reliability data. Thermal modeling showed low residual stress fields throughout the bulk of the cusps for both groups. Mechanical simulation depicted a shift in stress levels to the core of the alternative design compared with the standard design. Significantly higher reliability was found for the alternative core. Regardless of the alternative configuration, thermal and mechanical computer simulations showed stress in the alternative core design comparable and higher to that of the standard configuration, respectively. Such a mechanical scenario probably led to the higher reliability of the alternative design under fatigue.