19 resultados para Visitors classification


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: A major problem in Chagas disease donor screening is the high frequency of samples with inconclusive results. The objective of this study was to describe patterns of serologic results among donors to the three Brazilian REDS-II blood centers and correlate with epidemiologic characteristics. STUDY DESIGN AND METHODS: The centers screened donor samples with one Trypanosoma cruzi lysate enzyme immunoassay (EIA). EIA-reactive samples were tested with a second lysate EIA, a recombinant-antigen based EIA, and an immunfluorescence assay. Based on the serologic results, samples were classified as confirmed positive (CP), probable positive (PP), possible other parasitic infection (POPI), and false positive (FP). RESULTS: In 2007 to 2008, a total of 877 of 615,433 donations were discarded due to Chagas assay reactivity. The prevalences (95% confidence intervals [CIs]) among first-time donors for CP, PP, POPI, and FP patterns were 114 (99-129), 26 (19-34), 10 (5-14), and 96 (82-110) per 100,000 donations, respectively. CP and PP had similar patterns of prevalence when analyzed by age, sex, education, and location, suggesting that PP cases represent true T. cruzi infections; in contrast the demographics of donors with POPI were distinct and likely unrelated to Chagas disease. No CP cases were detected among 218,514 repeat donors followed for a total of 718,187 person-years. CONCLUSION: We have proposed a classification algorithm that may have practical importance for donor counseling and epidemiologic analyses of T. cruzi-seroreactive donors. The absence of incident T. cruzi infections is reassuring with respect to risk of window phase infections within Brazil and travel-related infections in nonendemic countries such as the United States.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we show the results of a comparison simulation study for three classification techniques: Multinomial Logistic Regression (MLR), No Metric Discriminant Analysis (NDA) and Linear Discriminant Analysis (LDA). The measure used to compare the performance of the three techniques was the Error Classification Rate (ECR). We found that MLR and LDA techniques have similar performance and that they are better than DNA when the population multivariate distribution is Normal or Logit-Normal. For the case of log-normal and Sinh(-1)-normal multivariate distributions we found that MLR had the better performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brazilian sugarcane spirits were analyzed to elucidate similarities and dissimilarities by principal component analysis. Nine aldehydes, six alcohols, and six metal cations were identified and quantified. Isobutanol (LD 202.9 mu gL-1), butiraldehyde (0.08-0.5 mu gL-1), ethanol (39-47% v/v), and copper (371-6068 mu gL-1) showed marked similarities, but the concentration levels of n-butanol (1.6-7.3 mu gL-1), sec-butanol (LD 89 mu gL-1), formaldehyde (0.1-0.74 mu gL-1), valeraldehyde (0.04-0.31 mu gL-1), iron (8.6-139.1 mu gL-1), and magnesium (LD 1149 mu gL-1) exhibited differences from samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coconut water is a natural isotonic, nutritive, and low-caloric drink. Preservation process is necessary to increase its shelf life outside the fruit and to improve commercialization. However, the influence of the conservation processes, antioxidant addition, maturation time, and soil where coconut is cultivated on the chemical composition of coconut water has had few arguments and studies. For these reasons, an evaluation of coconut waters (unprocessed and processed) was carried out using Ca, Cu, Fe, K, Mg, Mn, Na, Zn, chloride, sulfate, phosphate, malate, and ascorbate concentrations and chemometric tools. The quantitative determinations were performed by electrothermal atomic absorption spectrometry, inductively coupled plasma optical emission spectrometry, and capillary electrophoresis. The results showed that Ca, K, and Zn concentrations did not present significant alterations between the samples. The ranges of Cu, Fe, Mg, Mn, PO (4) (3-) , and SO (4) (2-) concentrations were as follows: Cu (3.1-120 A mu g L(-1)), Fe (60-330 A mu g L(-1)), Mg (48-123 mg L(-1)), Mn (0.4-4.0 mg L(-1)), PO (4) (3-) (55-212 mg L(-1)), and SO (4) (2-) (19-136 mg L(-1)). The principal component analysis (PCA) and hierarchical cluster analysis (HCA) were applied to differentiate unprocessed and processed samples. Multivariated analysis (PCA and HCA) were compared through one-way analysis of variance with Tukey-Kramer multiple comparisons test, and p values less than 0.05 were considered to be significant.