25 resultados para Validação : Métodos analíticos
Resumo:
Computational methods for the calculation of dynamical properties of fluids might consider the system as a continuum or as an assembly of molecules. Molecular dynamics (MD) simulation includes molecular resolution, whereas computational fluid dynamics (CFD) considers the fluid as a continuum. This work provides a review of hybrid methods MD/CFD recently proposed in the literature. Theoretical foundations, basic approaches of computational methods, and dynamical properties typically calculated by MD and CFD are first presented in order to appreciate the similarities and differences between these two methods. Then, methods for coupling MD and CFD, and applications of hybrid simulations MD/CFD, are presented.
Resumo:
Analysis at microenvironments, like single cells or in minute volumes (nL), is an area of great interest for analytical and biological sciences. Measurements at these experimental conditions demand analytical tools (microelectrodes) capable of monitoring with rapid response, good resolution and minimal perturbation of the system. The major drawbacks in producing these microscopic electrodes have been largely overcome, principally due to the development of new fabrication methods. In this review, these procedures are described with emphasis to those devoted to the construction of microelectrodes for application in microenvironments. Examples of our efforts to use these devices as effective electrochemical sensors are also addressed.
Resumo:
Em função de suas condições de interface entre águas doces e salinas, desembocaduras estuarinas e lagunares constituem sistemas geomorfológicos altamente complexos e dinâmicos. Como conseqüência da variabilidade espacial e temporal dos fluxos de maré, o leito responde com uma grande variabilidade nas características morfológicas e sedimentares. Neste sentido, é possível relacionar diretamente a circulação de fundo e o transporte sedimentar com as feições submersas geradas. Perfis de ecossondagem, sonar de varredura lateral e sísmica de alta resolução, executados na desembocadura lagunar de Cananéia, revelaram a existência de uma dinâmica de fundo extremamente complexa, caracterizada por marcas onduladas e ondas de areia de alturas métricas. As maiores ondas de areia, localizadas em uma depressão na desembocadura lagunar, apresentam inversão de polaridade em sua assimetria, com a presença de ondas simétricas de grande tamanho no ponto de inversão. Este padrão morfológico não apresenta variação temporal em escala anual, sugerindo a persistência de um padrão de fluxos sobre o leito. Esta dinâmica revela, também, a constância de fluxos convergentes que aparentemente independem das condições de maré enchente ou vazante. Os resultados permitiram o estabelecimento de um primeiro modelo qualitativo de circulação de fundo na área, com aplicações potenciais na navegação e estudos de proteção da costa.
Resumo:
O objetivo deste estudo foi validar e confirmar a reprodutibilidade de uma escala de silhueta para adolescentes. Para tanto, pesquisou-se 386 jovens de uma Escola Particular de Ensino. Desenvolveram-se análises de validação de construto e reprodutibilidade. O instrumento foi capaz de discriminar os quatro grupos segundo estado nutricional (α2=30,5, p<0,001; α2=19,3, p<0,001), correlacionou-se com as três medidas (IMC, RCQ e CC) pesquisadas (r=-0,61, p<0,001, r=-0,49, p<0,001, r=-0,54, p<0,001; r=-0,52, p<0,001, r=-0,23, p=0,001, r=-0,42, p<0,001) e confirmou a reprodutibilidade por meio da correlação intra-classe (r icc=0,86, p<0,001; r icc=0,80, p<0,001) para meninos e meninas, respectivamente. Na comparação das médias dos escores da escala (teste-reteste) confirmou-se a reprodutibilidade somente para o grupo dos meninos (p=0,86). O instrumento apresentou boa compreensão verbal e bom tempo de conclusão. Conclui-se que a escala de silhueta demonstrou bons resultados nas análises de validação e de reprodutibilidade.
Resumo:
OBJETIVO: Comparar duas abordagens baseadas em critérios do Quality Assessment of Diagnostic Accuracy Studies (QUADAS) e do Standards for Reporting Studies of Diagnostic Accuracy (STARD) na avaliação de qualidade de estudos de validação do teste rápido OptiMal®, para diagnóstico de malária. MÉTODOS: Foi realizada busca de artigos de validação do teste rápido na base bibliográfica Medline acessada pelo PubMed, no ano de 2007. Treze artigos foram recuperados na busca. Foram combinados 12 critérios do QUADAS e três do STARD para comparação com os critérios do QUADAS isoladamente. Foi considerado que artigos de regular a boa qualidade atenderiam pelo menos 50% dos critérios do QUADAS. RESULTADOS: Dos 13 artigos recuperados, 12 cumpriram pelo menos 50% dos critérios do QUADAS, e apenas dois atenderam à combinação dos critérios. Considerando-se a combinação dos dois critérios (> 6 QUADAS e > 3STARD), dois estudos (15,4%) apresentaram boa qualidade metodológica. A seleção de artigos usando a combinação proposta variou de dois a oito artigos, dependendo do número de itens considerados como ponto de corte. CONCLUSÕES: A combinação do QUADAS com o STARD tem o potencial de conferir maior rigor nas avaliações da qualidade de artigos publicados sobre validação de testes diagnósticos em malária, por incorporar a checagem de informações relevantes não alcançáveis pelo uso do QUADAS isoladamente.
Resumo:
OBJECTIVES: to produce evidence of the validity and reliability of the Body Shape Questionnaire (BSQ) - a tool for measuring an individual's attitude towards his or her body image. METHODS: the study covered 386 young people of both sexes aged between 10 and 18 from a private school and used self-applied questionnaires and anthropometric evaluation. It evaluated the internal consistency, the discriminant validity for differences from the means, according to nutritional status (underweight, eutrophic, overweight and obese), the concurrent validity by way of Spearman's correlation coefficient between the scale and the Body Mass Index (BMI), the waist-hip circumference ratio (WHR) and the waist circumference (WC). Reliability was tested using Wilcoxon's Test, the intraclass correlation coefficient and the Bland-Altman figures. RESULTS: the BSQ displayed good internal consistency (±=0.96) and was capable of discriminating among the total population, boys and girls, according to nutritional status (p<0.001). It correlated with the BMI (r=0.41; p<0.001), WHR (r=-0.10; p=0.043) and WC (r=0.24; p<0.001) and its reliability was confirmed by intraclass correlation (r=0.91; p<0.001) for the total population. The questionnaire was easy to understand and could be completed quickly. CONCLUSIONS: the BSQ presented good results, thereby providing evidence of its validity and reliability. It is therefore recommended for evaluation of body image attitudes among adolescents.
Resumo:
This study describes the validity of a food frequency questionnaire (FFQ) in 93 low-income women (20-65 years), participating in a case-control study in São Paulo, Brazil. Two FFQ (FFQ1 and FFQ2, 12 months apart) and three 24-hour dietary recalls (24hR) were conducted between 2003 and 2004 to estimate dietary intake during the past year. The Pearson correlation coefficients (crude, energy-adjusted and de-attenuated) were used for comparisons between FFQ and 24hR. The agreement between the methods was further examined by the Bland-Altman analysis. For the assessment of long-term reliability, the energy-adjusted intra-class correlation coefficients were mostly around 0.40, but higher for vitamin A and folate (0.50-0.56). Energy-adjusted, attenuation-corrected Pearson validity correlations between FFQ and DR ranged from 0.30-0.54 for macronutrients to 0.20-0.48 for micronutrients, with higher value for calcium (0.75). There were small proportions of grossly misclassified nutrient intakes, while Bland-Altman plots indicated that the FFQ is accurate in assessing nutrient intake at a group level.
Resumo:
OBJETIVO: Avaliar a validade do peso, estatura e Índice de Massa Corporal (IMC) referidos e sua confiabilidade para o diagnóstico do estado nutricional de adolescentes de Piracicaba. MÉTODOS: Participaram do estudo 360 adolescentes de ambos os sexos, de escolas públicas de Piracicaba, com idade entre 10 e 15 anos. Os adolescentes auto-relataram seu peso e estatura, sendo esses valores obtidos por medidas diretas, logo em seguida, pelos entrevistadores. A validade do IMC referido foi calculada segundo índices de sensibilidade, especificidade e valor preditivo positivo (VPP). Avaliou-se a concordância entre as categorias de IMC obtido por meio das medidas referidas e aferidas a partir do coeficiente kappa ponderado, coeficiente de correlação de Lin. e gráficos de Bland e Altman e Lin. RESULTADOS: Verificou-se que tanto os meninos quanto as meninas subestimaram o peso (-1,0 meninas e meninos) e a estatura (meninas -1,2 e meninos -0,8) (p < 0,001). Os valores de IMC aferidos e referidos apresentaram uma concordância moderada. A sensibilidade do IMC referido para classificar os indivíduos obesos foi maior para os meninos (87,5%), enquanto a especificidade foi maior para as meninas (92,7%). O VPP foi elevado somente para a classificação da eutrofia. CONCLUSÕES: As medidas referidas de peso e estatura de adolescentes não representam medidas válidas e, portanto, não devem ser usadas em substituição aos valores mensurados. Além disso, verificou-se que 10% dos meninos obesos e 40% das meninas obesas poderiam permanecer não identificados utilizando-se as medidas auto-referidas, confirmando a baixa validade das medidas auto-referidas.
Resumo:
Foram comparados dois métodos não-invasivos de medida da pressão arterial, o Doppler vascular e o oscilométrico, com o objetivo de estabelecer parâmetros que possam auxiliar no diagnóstico seguro da hipertensão arterial. Para tal, foram utilizados 45 cães, machos e fêmeas, distribuídos em três grupos de acordo com o peso, pequeno, médio e grande porte. Em cada animal, procedeu-se a mensuração por meio do Doppler vascular e, em seguida, do oscilométrico. Na obtenção da pressão arterial sistólica, não houve diferença entre os métodos nos três grupos de animais, porém, na obtenção da pressão arterial diastólica, houve diferença estatística entre o Doppler vascular e o oscilométrico nos grupos de animais de pequeno e médio porte. Pôde-se concluir que valores confiáveis de pressão sistólica podem ser obtidos tanto por meio do Doppler vascular quanto do oscilométrico. Os valores da pressão arterial diastólica obtidos pelos dois métodos não se correlacionam, principalmente nos animais de pequeno e médio porte.
Resumo:
Modelo para o estudo de diversas doenças humanas, o hamster tem sido objeto de numerosos estudos comportamentais e envolvendo estresse e/ou comportamento agonístico que supõem, muitas vezes, o monitoramento das flutuações hormonais nos indivíduos envolvidos. O objetivo do presente trabalho foi confirmar a adequação de um conjunto comercial para dosagem de testosterona em sangue humano para a quantificação de metabólitos fecais de testosterona (MFT) em hamsters Sírios machos e fêmeas. Dez machos foram submetidos a um desafio com um agonista de GnRH para estimular a atividade testicular, elevando os níveis circulantes de testosterona. Cinco fêmeas receberam uma injeção de testosterona enquanto cinco outras receberam uma injeção de solução salina. Amostras de fezes coletadas antes e depois dos procedimentos, assim como amostras fecais de 20 fêmeas gestantes coletadas ao longo da gestação foram analisadas com um conjunto comercial para radioimunoensaio. Um pico de MFT 12h após a injeção seguido de uma queda abaixo do nível basal comprovou que, nos machos, as alterações nos níveis de MFT refletem as alterações da concentração de testosterona no sangue. Nestes observou-se um ciclo circadiano das concentrações de MFT com acrofase no início do período claro correspondendo ao ciclo descrito para as concentrações sanguíneas na literatura. Nas fêmeas a administração de testosterona exógena provocou uma elevação importante dos níveis de MFT, mas as concentrações medidas ao longo da gestação não refletiram o padrão dos níveis sanguíneos do hormônio endógeno. O conjunto para radioimunoensaio para testosterona em sangue humano mostrou-se adequado para o monitoramento da função testicular no hamster macho, mas um ensaio mais específico seria necessário para as fêmeas.