28 resultados para Vélocimétrie Doppler
Resumo:
Objectives/Hypothesis: Blood supply to the Hadad-Bassagasteguy pedicled nasoseptal flap may be interrupted by surgery of the pterygopalatine fossa, posterior septectomy, or large sphenoidotomies. This would preclude its use for reconstruction of skull base defects after expanded endonasal approaches (EEA). We present a novel method to ascertain the patency of the nasoseptal artery after prior surgery, and consequently the availability of the nasoseptal flap, using acoustic Doppler sonography. Study Design: Retrospective clinical review. Methods: Four patients who underwent EEAs were evaluated intraoperatively with acoustic Doppler sonography. The mucosa that covers the inferior aspect of the rostrum of the sphenoid sinus was scanned with the tip of the probe. Reflection of sound waves representing intravascular blood flow was assessed. Results: In three patients, the artery was identified in at least one side. One remaining patient showed no acoustic signal suggesting loss of the nasoseptal artery bilaterally, therefore necessitating the use of a fat graft for the reconstruction. Conclusions: Acoustic Doppler sonography seems to be a feasible and effective way to ascertain the availability of the nasoseptal artery. It is a relatively inexpensive and simple technique that can be performed by any endoscopic surgeon.
Resumo:
Objective To determine normal blood flow velocities across the fetal tricuspid valve (TV) at 11-13 weeks and 6 days of gestation and to examine the reproducibility of these measurements. Methods A prospective study involving 166 normal singleton pregnancies examined at 11-13 weeks and 6 days was carried out. Descriptive analysis of E- and A-waves` maximum velocities, E/A ratio, duration of the cardiac cycle (C) and diastole (D) and D/C ratio were calculated. Intraobserver and interobserver agreement analysis was performed in a subgroup of 12 cases. Results Average (+/- SD) flow velocities were: E-wave, 25.0 (+/- 4.6) cm/s; A-wave. 42.9 (+/- 5.9) cm/s; E/A, 0.58 (+/- 0.07); cardiac cycle, 390 (+/- 21.1) ms; diastole, 147 (+/- 18) ms and D/C, 0.38 (+/- 0.04). Significant correlation was observed between all parameters (except A-wave) and gestational age but not with nuchal translucency (NT). Intraclass correlation coefficients (interobserver, intraobsever examiner I and intraobserver examiner 2) were: E-wave, 0.53, 0.53 and 0.64; A-wave, 0.45, 0.46 and 0.49; cardiac cycle, 0.70, 0.79 and 0.84 and diastole, 0.63, 0.85 and 0.82, respectively. Conclusions The present study establishes normal Doppler parameters for blood flow across the TV at 11 - 13 weeks and 6 days and demonstrates that these parameters do not correlate with NT measurement and have good/moderate reproducibility. Copyright (C) 2010 John Wiley & Sons, Ltd.
Resumo:
Background: The relation between left ventricular filing velocities determined by Doppler echocardiography and autonomic nervous system function assessed by heart rate variability (HRV) is unclear. The aim of this study was to evaluate the influence of the autonomic nervous system assessed by the time and frequency domain indices of HRV in the Doppler indices of left ventricular diastolic filling velocities in patients without heart disease. Methods: We studied 451 healthy individuals (255 female [56.4%]) with normal blood pressure, electrocardiogram, chest x-ray, and treadmill electrocardiographic exercise stress test results, with a mean age of 43 +/- 12 (range 15-82) years, who underwent transthoracic Doppler echocardiography and 24-hour electrocardiographic ambulatory monitoring. We studied indices of HRV on time (standard deviation [SD] of all normal sinus RR intervals during 24 hours, SD of averaged normal sinus RR intervals for all 5-minute segments, mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms) and frequency (low frequency, high frequency, very low frequency, low frequency/high frequency ratio) domains relative to peak flow velocity during rapid passive filling phase (E), atrial contraction (A), E/A ratio, E-wave deceleration time, and isovolumic relaxation time. Statistical analysis was performed with Pearson correlation and logistic regression. Results: Peak flow velocity during rapid passive filling phase (E) and atrial contraction (A), E/A ratio, and deceleration time of early mitral inflow did not demonstrate a significant correlation with indices of HRV in time and frequency domain. We found that the E/A ratio was < 1 in 45 individuals (10%). Individuals with an E/A ratio < 1 had lower indices of HRV in frequency domain (except low frequency/high frequency) and lower indices of the mean of the SD of all normal sinus RR intervals for all 5-minute segments, root-mean-square of the successive normal sinus RR interval difference, and percentage of successive normal sinus RR intervals > 50 ms in time domain. Logistic regression demonstrated that an E/A ratio < 1 was associated with lower HF. Conclusion: Individuals with no evidence of heart disease and an E/A ratio < 1 demonstrated a significant decrease in indexes of HRV associated with parasympathetic modulation. (J Am Soc Echocardiogr 2010;23: 762-5.)
Resumo:
Background. Heart transplantation (OHT) has traditionally been contraindicated in the presence of severe pulmonary hypertension (PH), as detected by right heart catheterization. Noninvasive methods are still not reliably accurate to make this evaluation. Objectives. Determine the efficacy of echo Doppler analysis for the diagnosis of severe PH. Methods. One hundred thirty patients (mean age = 42 +/- 15 years, 82 men) showed severe left ventricular dysfunction (mean ejection fraction = 29 +/- 12%; functional class III-IV). We excluded patients with atrial fibrillation, heart failure secondary to congenital disease, and valvulopathy. The pulmonary parameters defined as severe PH were: systolic pulmonary artery pressure (sPAP) >= 60 mm Hg; a mean transpulmonary gradient >= 15; or pulmonary vascular resistance >= 5 Wood units. Patients underwent a right heart catheterization using a Swan-Ganz catheter to measure hemodynamic parameters and to noninvasively estimate right-sided pressures from spectral Doppler recordings of tricuspid regurgitation velocity (right ventricular systolic pressure [RVsP]). A Pearson correlation of sPAP was obtained with RVsP by; the sensitivity of RVsP for the diagnosis of PH was determined by a receiver operating characteristic (ROC) curve. Results. A good correlation between sPAP and RVsP was obtained by Pearson correlation analysis (r = 0.64; 95% confidence interval [CI] 0.50-0.75; P < .001). The ROC curve analysis showed a sensitivity of 100%, a specificity of 37.2%, (95% CI 0.69-0.83, P < .0001) of a RVsP < 45 mm Hg (cutoff) on the exclusion of severe PH. Conclusions. The cutoff of RVsP < 45 mm Hg, on noninvasive echo Doppler evaluation of PH is an efficient method to replace invasive heart catheterization in OHT candidates.
Resumo:
The aim of this study was to evaluate the arterial and venous blood flow in women who underwent upper limb axillary dissection surgery for the treatment of breast cancer. Sixty women were divided into two groups: group 1 (G1)-30 women who underwent breast surgery with axillary dissection level II or III (55.6 +/- A 8.6 years); group 2 (G2)-control, 30 women with no breast cancer (57.4 +/- A 7.0 years). Blood flow profile was evaluated by a continuous wave ultrasound Doppler device (Nicolet Vascular Versalab SE(A (R))) with an 8 MHz probe. Axillary, brachial arteries and veins, arm circumference, volumes, and the ankle-brachial index (ABI) were examined. Wilcoxon test and Mann-Whitney tests were applied to analyze blood flow velocity intra-group and between G1 and G2, respectively. The G1 results showed no lymphedema and no peripheral arterial disease (ABI > 0.9). Moreover, the mean blood flow velocity of the vessels ipsilateral to the surgery was significantly higher than the contralateral ones for all vessels examined (P < 0.05). The mean velocity of blood flow of the vessels contralateral to surgery was significantly higher than the axillary artery in G2 (P < 0.05). It can be concluded that women who underwent axillary dissection due to breast cancer showed probable stenosis in the arterial and venous axillary and brachial vessels of the upper limb ipsilateral to the surgery, confirmed by the increase of blood flow velocity, and such obstruction might affect the limb contralateral to the operation site.
Resumo:
Background: There is only limited knowledge on how the quantification of valvular regurgitation by color Doppler is affected by changing blood viscosity. This study was designed to evaluate the effect of changing blood viscosity on the vena contracta width using an in vitro model of valvular insufficiency capable of providing ample variation in the rate and stroke volume. Methods: We constructed a pulsatile flow model filled with human blood at varying hematocrit (15%, 35%, and 55%) and corresponding blood viscosity (blood/water viscosity: 2.6, 4.8, 9.1) levels in which jets were driven through a known orifice (7 mm(2)) into a 110 mL compliant receiving chamber (compliance: 2.2 mL/mmHg) by a pulsatile pump. In addition, we used variable pump stroke volumes (5, 7.5, and 10 mL) and rates (40, 60, and 80 ppm). Vena contracta region was imaged using a 3.5 MHz transducer. Pressure and volume in the flow model were kept constant during each experimental condition, as well as ultrasound settings. Results: Blood viscosity variation in the experimental range did not induce significant changes in vena contracta dimensions. Also, vena contracta width did not change from normal to low hematocrit and viscosity levels. A very modest increase only in vena contracta dimension was observed at very high level of blood viscosity when hematocrit was set to 55% . Pump rate, in the evaluated range, did not influence vena contracta width. These results in controlled experimental settings suggest that the vena contracta is an accurate quantitative method for quantifying valvular regurgitation even when this condition is associated with anemia, a frequent finding in patients with valvular heart disease.
Resumo:
We evaluated 16 pregnant women with gestational age between 20 and 32 weeks in acute severe hypertension which were randomly allocated to receive either hydralazine or labetalol. Blood pressure and Doppler ultrasound parameters from maternal uterine and fetal middle cerebral and umbilical arteries were assessed during acute severe hypertension and after treatment. A significant reduction in systolic and diastolic blood pressure was observed in both groups. A significant change in Doppler parameters was observed only in pregnant women who received hydralazine: an increase in uterine arteries resistance index. We concluded that both drugs were highly effective in reducing blood pressure in these women. Despite the observed increase in resistance index of uterine arteries associated with hydralazine, the use of hydralazine and labetalol were not related to any significant changes in fetal Doppler, which is reassuring about the safety of these drugs when treating acute severe hypertension in pregnancy. (E-mail: wpmartins@gmail.com) (C) 2011 World Federation for Ultrasound in Medicine & Biology.
Resumo:
The aim of this study was to establish normal ranges of blood flow velocities and indices in the fetal ductus venosus (DV) during the second half of normal pregnancy. A Doppler study of 60 healthy pregnant women without fetal pathologies was performed during the second half of pregnancy. The peak systolic velocity (PSV), peak diastolic velocity (PDV), maximum velocity during atrial contraction (VAC), peak systolic velocity/maximum velocity during atrial contraction (S/A ratio), pulsatility index for the vein (PIV), preload index (PLI) and velocity index for the vein (VIV) were calculated from the DV at 4-week intervals. A significant increase in PSV, PDV and VAC was observed from the 20-23(6/7) to the 28-31(6/7) weeks, with stabilization of values until the end of the pregnancy. On the other hand, the study showed a significant decrease for the S/A ratio, PIV, PLI and VIV from the 20-23(6/7) to the 28-31(6/7) weeks and remaining stable from then until term. (E-mail:dralemar@uol.com.br) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Objectives To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in `flow-free` models. Methods 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PR F) settings. Results Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Conclusions Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. Copyright (C) 2010 ISUOC. Published by John Wiley & Sons, Ltd.
Resumo:
Background: One of the frequent questions in obstetric practice is to determine placental vascular changes that may account for abnormal Doppler flow velocity alterations in maternal uterine vessels from women and fetuses without pregnancy pathology. Methods: A retrospective morphometric study was realized using 27 placentas from patients submitted for Doppler flow velocity exam during pregnancy. The placentas were morphologically examined using hematoxylin-eosin staining. Measurements of villi were made with the use of a video camera coupled to a common light microscope and a computer with automatic image analyzing software. Results: Of the 27 placentas, 13 (48%) were of patients showing unaltered Doppler and 14 (52%) showing altered Doppler. The number of stem villi vessels was significantly larger in the placentas of patients with Doppler exam alterations (P = 0.003). This group also presented greater stem villi vessel thickness, although without significant difference. The number of intermediary and terminal villi vessels was greater in the placentas of patients with altered Doppler exams (P < 0.001), and a greater terminal villi area was observed in these cases (P < 0.001). Conclusion: The morphological proof that uterine artery Doppler flow velocity exam alterations are associated with placental vascular alterations demonstrates the importance of this exam during prenatal care, even in the absence of maternal-fetal alterations.
Resumo:
Background: Although the influence of respiration on ventricular filling, as evaluated by Doppler technique, and the evaluation of diastolic velocities of mitral valve annulus (MVA), as measured by Doppler tissue imaging (DTI), can provide valuable information for the study of left ventricular (LV) diastolic function, the concomitant effects of aging, tidal volume (TV), and respiratory rate (RR) on these velocities have not been quantitatively investigated. Methods: We evaluated 12 normal male volunteers (Group I) aged 20-26 years (mean: 22.8) and 8 normal subjects aged 41 to 54 years old (mean: 45.9) (Group II). Using DTI we measured peak early (E-a) and late (A(a)) velocities of longitudinal axis expansion at lateral and medial MVA. Doppler mitral and tricuspid flow velocities were measured: peak early (E) and late (A) inflow velocity, early (E-i) and late (A(i)) flow integral, and deceleration time of peak early mitral flow velocity (DT). Respiratory cycles were simultaneously recorded at RR of 9, 12, 15, and 18 cycles/min and TV of 600 and 900 mL during respiration (RESP). Results and conclusions: (1) E, A, and A(i) in MV had negligible change during respiration, but E-i was significantly reduced during inspiration; (2) DT reduced slightly with inspiration, but the change was significant only with TV of 900 mL; (3) an important increase of E in right ventricular flow was observed during inspiration; (4) variations of RR and TV did not significantly influence right and left ventricular inflow in normal subjects, in the conditions of this investigation; (5) a significant increase of E-a at medial MVA was documented during inspiration only in young subjects; (6) a significant decrease of A(a) at medial MVA was observed during inspiration in both groups of volunteers; (7) RR and TV did not influence MVA velocities in young and adult subjects; (8) a consistent reduction in E-a and a significant increase in A(a) were observed with increasing age; (9) these changes were more conspicuous and consistent than those documented in ventricular filling when young and middle-age men are compared, suggesting that the DTI is more sensitive to detect changes in diastolic function; and (10) in addition, these data suggest that, for evaluation of diastolic function, in clinical context, it is not necessary to control rigorously RR or TV.
Resumo:
The objective of this study was to describe multiple Doppler ultrasound parameters of ductus venosus and inferior vena cava in fetuses at gestational ages ranging from 22 to 38 weeks. In this prospective observational study, Doppler ultrasound exams were performed in 45 healthy fetuses at 22, 26, 34, and 38 weeks. Maximum venous velocity, minimum venous velocity, venous pulsatility index, and venous acceleration time (VAT) (defined as the time between minimum and maximum venous velocity) were evaluated at those gestational periods. Increase in the velocities and decrease in the pulsatility index were observed in these vessels throughout gestational age. The VAT increased with gestational age. The VAT, a Doppler parameter still not described elsewhere, increased during pregnancy could be related to a longer period of time needed to fill the atrium in bigger hearts. In this study, we provide reference values for VAT in healthy fetuses.
Resumo:
We report a statistical analysis of Doppler broadening coincidence data of electron-positron annihilation radiation in silicon using a (22)Na source. The Doppler broadening coincidence spectrum was fit using a model function that included positron annihilation at rest with 1s, 2s, 2p, and valence band electrons. In-flight positron annihilation was also fit. The response functions of the detectors accounted for backscattering, combinations of Compton effects, pileup, ballistic deficit, and pulse-shaping problems. The procedure allows the quantitative determination of positron annihilation with core and valence electron intensities as well as their standard deviations directly from the experimental spectrum. The results obtained for the core and valence band electron annihilation intensities were 2.56(9)% and 97.44(9)%, respectively. These intensities are consistent with published experimental data treated by conventional analysis methods. This new procedure has the advantage of allowing one to distinguish additional effects from those associated with the detection system response function. (C) 2009 Elsevier B.V. All rights reserved.