22 resultados para Sense and reference
Resumo:
In the present study a fast, sensitive and robust validated method to quantify chlorpheniramine in human plasma using brompheniramine as internal standard (IS) is described. The analyte and the IS were extracted from plasma by LLE (diethyl ether-dichloromethane, 80:20, v/v) and analyzed by HPLC-ESI-MS/MS. Chromatographic separation was performed using a gradient of methanol from 35 to 90% with 2.5 mm NH(4)OH on a Gemini Phenomenex C(8) 5 mu m column (50 x 4.6 mm i.d.) in 5.0 min/run. The method fitted to a linear calibration curve (0.05-10 ng/mL, R > 0.9991). The precision (%CV) and accuracy ranged, respectively: intra-batch from 1.5 to 6.8% and 99.1 to 106.6%, and inter-batch from 2.4 to 9.0%, and 99.9 to 103.1%. The validated bioanalytical procedure was used to assess the comparative bioavailability in healthy volunteers of two dexchlorpheniramine 2.0 mg tablet formulations (test dexchlorpheniramine, Eurofarma, and reference Celestamine (R), Schering-Plough). The study was conducted using an open, randomized, two-period crossover design with a 2 week washout interval. Since the 90% confidence interval for C(max) and AUC ratios were all within the 80-125% interval proposed by ANVISA and FDA, it was concluded that test and reference formulations are bioequivalent concerning the rate and the extent of absorption. Copyright (C) 2009 John Wiley & Sons, Ltd.
Resumo:
Two different cefadroxil (CAS 50370-12-2) formulations were evaluated for their relative bioavailability in 24 healthy volunteers who received a single 500 mg oral dose of each preparation. An open, randomized clinical trial designed as a two-period crossover study with a 7-day washout period between doses was employed. Plasma samples for assessments of their cefadroxil concentration by HPLC-UV were obtained over 8 h after administration. Values of 48.94 +/- 10.18 mu g . h/ml for test, and 48.51 +/- 9.02 mu g . h/ml for the reference preparation AUC(0-t) demonstrate a nearly identical extend of drug absorption. Maximum plasma concentration C-max of 16.04 +/- 4.94 mu g/ml and 16.01 +/- 4.02 mu g/ml achieved for the test and reference preparations did not differ significantly. The parametric 90% confidence intervals (CI) of the mean of the difference (test-reference) between log-transformed values of the two formulations were 96.80% to 104.51% and 92.01% to 107.00% for AUC(0-t) and C-max, respectively. Since for both AUC(0-t) or C-max the 90% CI values are within the interval proposed by the Food and Drug Administration, the test product is bioequivalent to the reference product for both the rate and extent of absorption after single dose administration.
Resumo:
Background: Risperidone (RSP) is a benzisoxazole antipsychotic agent used to treat schizophrenia and other psychiatric illnesses in adults and children (including those with autism). After oral administration, RSP is completely absorbed from the gastrointestinal tract and undergoes hydroxylation to yield 9-hydroxyrisperidone (9-OH-RSP), an active metabolite that has a pharmacologic profile and potency similar to RSP. Objectives: The aims of this study were to compare the relative bioavailability of a pharmaceutical-equivalent (test) formulation with a reference formulation of oral RSP 2 mg, both available commercially on the Brazilian pharmaceutical market, and to generate data regarding the oral bioavailability of the tested drug in healthy Brazilian volunteers. Methods: This single-dose, randomized-sequence, open-label, 2-period crossover study was conducted in healthy Brazilian volunteers from August to December 2008. Subjects were randomly assigned to receive the test formulation followed by the reference formulation or vice versa, with a 30-day washout period between doses. Study drugs were administered after a 12-hour overnight fast. For pharmacokinetic analysis, blood samples were drawn at 0 (baseline), 0.25, 0.5, 1, 1.5, 3, 5, 8, 12, 24, 48, 72, 96, and 120 hours after administration. Plasma concentrations of RSP and 9-OH-RSP were determined using LC-MS/MS. The test and reference formulations were to be considered bioequivalent if the 90% CIs for the geometric mean test/reference ratios were within a predetermined range of 80% to 125%, in accordance with the policies of the Brazilian Sanitary Surveillance Agency and the US Food and Drug Administration. Tolerability was determined using clinical assessments, monitoring of vital signs, analysis of laboratory test results, and subject interviews regarding adverse events. Results: A total of 22 subjects were enrolled (11 men, 11 women; mean [SD] age, 32 [12] years [range, 18-58 years]; weight, 70.4 [11.9] kg [range, 50-103 kg]; height, 1.67 [0.08] m [range, 1.56-1.80 m]; and body mass index, 25 [4] kg/m(2) [range, 18-29 kg/m(2)]). For RSP, mean (SD) C(max) values were 12.6 (2.7) and 16.0 (2.3) ng/mL for the test and reference formulations, respectively. For 9-OH-RSP, mean C(max) values were 17.8 (1.3) and 21.0 (1.7) ng/mL for the test and reference formulations. The 90% CIs for the mean test/reference ratios for RSP C(max), AUC(0-120), and AUC(0-infinity) were 74% to 82%, 75% to 85%, and 76% to 85%, respectively, and 83% to 87%, 75% to 79%, and 75% to 78% for 9-OH-RSP. The related adverse events (headache, low back pain, drowsiness, standing hypotension, local postvenipuncture ecchymoses, insomnia, nausea, and vomiting) were transient and mild. Conclusions: This single-dose study found that the test and reference formulations of oral RSP 2 mg did not meet the Brazilian and US regulatory criteria for bioequivalence in these fasting, healthy volunteers. The study formulations appeared to be well tolerated. (Clin Ther 2010;32:2106-2115) (C) 2010 Elsevier HS Journals, Inc.
Resumo:
Background: The Cambridge Cognitive Examination (CAMCOG) is a useful test in screening for Alzheimer`s disease (AD). However, the interpretation of CAMCOG cut-off scores is problematic and reference values are needed for different educational strata. Given the importance of earlier diagnoses of mild dementia, new cut-off values are required which take into account patients with low levels of education. This study aims to evaluate whether the CAMCOG can be used as an accurate screening test among AD patients and normal controls with different educational levels. Methods: Cross-sectional assessment was undertaken of 113 AD and 208 elderly controls with heterogeneous educational levels (group 1: 1-4 years; group 2: 5-8 years; and group 3: >= 9 years) from a geriatric clinic. submitted to a thorough diagnostic evaluation for AD including the Cambridge Examination for Mental Disorders of the Elderly (CAMDEX). Controls had no cognitive or mood complaints. Sensitivity (SE) and specificity (SP) for the CAMCOG in each educational group was assessed with receiver-operator-characteristic (ROC) curves. Results: CAMCOG mean values were lower when education was reduced in both diagnostic groups (controls - group 1: 87; group 2: 91; group 3: 96; AD - group 1: 63; group 2: 62; group 3: 77). Cutoff scores for the three education groups were 79, 80 and 90, respectively. SE and SP varied among the groups (group 1: 88.1% and 83.5%; group 2: 84.6% and 96%; group 3: 70.8% and 90%). Conclusion: The CAMCOG can be used as a cognitive test for patients with low educational level with good accuracy. Patients with higher education showed lower scores than previously reported.
Resumo:
SETTING: Itaborai Municipality in Rio de Janeiro, Brazil. OBJECTIVE: To evaluate access to tuberculosis (TB) diagnosis for users of the Family Health Program (FHP) and Reference Ambulatory Units (RAUs). DESIGN : A cross-sectional study was conducted in Itaborai City, Rio de Janeiro, Brazil. Between July and October 2007, a sample of 100 TB patients registered consecutively with the TB Control Program was interviewed using the primary care assessment tool. The two highest scores, describing `almost always` and `always`, or `good` and `very good`, were used as a cut-off point to define high quality access to diagnosis. RESULTS: FHP patients were older and had less education than RAU interviewees. Sex and overcrowding did not differ in the two groups. Patient groups did not differ with regard to the number of times care was sought at a unit, transport problems, cost of attending units and availability of consultation within 24 h. Adequate access to diagnosis was identified by 62% of the FHP patients and 53% of the RAU patients (P = 0.01). CONCLUSION: In Itaborai, Rio de Janeiro, TB patients believe that the FHP units provide greater access to TB diagnosis than RAUs. These findings will be used by the Department of Health to improve access to diagnosis in Itaborai.
Resumo:
People with disabilities have a right to a full life in every sense and one of those fundamental rights is the possibility to work. In this paper, the importance of social employment integration of disabled people is highlighted as one of the stakeholders to be satisfied by companies in the new framework that corporate social responsibility is constructing. The objective of the paper is to revise the benefits of some well-known operations research/management science tools that, if applied correctly, have a double positive impact on work accessibility and improved productivity. The responses collected from managers of Valencia`s ShelteredWork Centres for Disabled by means of a structured questionnaire are used to analyse the level of implementation of these tools and their impact depending on the type of centre, the kind of disability and other structural variables.
Resumo:
Titanium alloys, alloys, especially beta-type alloys containing beta-stabilizing elements, constitute a highly versatile category of metallic materials that have been under constant development for application in orthopedics and dentistry. This type of alloy generally presents a high mechanical strength-to-weight ratio, excellent corrosion resistance and low elastic modulus. The purpose of this study is to evaluate the cytotoxicity and adhesion of fibroblast cells on titanium alloy substrates containing Nb, Ta, Zr, Cu, Sn and Mo alloying elements. Cells cultured on polystyrene were used as controls. In vitro results with Vero cells demonstrated that the tested materials, except Cu-based alloy, presented high viability in short-term testing. Adhesion of cells cultured on disks showed no differences between the materials and reference except for the Ti-Cu alloy, which showed reduced adhesion attributed to poor metabolic activity. Titanium alloys with the addition of Nb, Ta, Zr, Sn and Mo elements show a promising potential for biomedical applications. (C) 2011 Elsevier B.V. All rights reserved.