37 resultados para Section 504


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a measurement of the longitudinal double-spin asymmetry A(LL) and the differential cross section for inclusive pi(0) production at midrapidity in polarized proton collisions at s=200 GeV. The cross section was measured over a transverse momentum range of 1 < p(T)< 17 GeV/c and found to be in good agreement with a next-to-leading order perturbative QCD calculation. The longitudinal double-spin asymmetry was measured in the range of 3.7 < p(T)< 11 GeV/c and excludes a maximal positive gluon polarization in the proton. The mean transverse momentum fraction of pi(0)'s in their parent jets was found to be around 0.7 for electromagnetically triggered events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The absorption cross section of Reissner-Nordstroumlm black holes for the electromagnetic field is computed numerically for arbitrary frequencies, taking into account the coupling of the electromagnetic and gravitational perturbations. We also compute the conversion coefficients of electromagnetic to gravitational waves by scattering from a Reissner-Nordstroumlm black hole.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that bifurcations in chaotic scattering manifest themselves through the appearance of an infinitely fine-scale structure of singularities in the cross section. These ""rainbow singularities"" are created in a cascade, which is closely related to the bifurcation cascade undergone by the set of trapped orbits (the chaotic saddle). This cascade provides a signature in the differential cross section of the complex pattern of bifurcations of orbits underlying the transition to chaotic scattering. We show that there is a power law with a universal coefficient governing the sequence of births of rainbow singularities and we verify this prediction by numerical simulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The absorption cross section of Reissner-Nordstrom black holes for the electromagnetic field is computed numerically for arbitrary frequencies. The numerical results are in excellent agreement with the low- and high-frequency limits, which are obtained with analytical methods. Special emphasis is given to the extreme Reissner-Nordstrom black hole case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most ordinary finite element formulations for 3D frame analysis do not consider the warping of cross-sections as part of their kinematics. So the stiffness, regarding torsion, should be directly introduced by the user into the computational software and the bar is treated as it is working under no warping hypothesis. This approach does not give good results for general structural elements applied in engineering. Both displacement and stress calculation reveal sensible deficiencies for both linear and non-linear applications. For linear analysis, displacements can be corrected by assuming a stiffness that results in acceptable global displacements of the analyzed structure. However, the stress calculation will be far from reality. For nonlinear analysis the deficiencies are even worse. In the past forty years, some special structural matrix analysis and finite element formulations have been proposed in literature to include warping and the bending-torsion effects for 3D general frame analysis considering both linear and non-linear situations. In this work, using a kinematics improvement technique, the degree of freedom ""warping intensity"" is introduced following a new approach for 3D frame elements. This degree of freedom is associated with the warping basic mode, a geometric characteristic of the cross-section, It does not have a direct relation with the rate of twist rotation along the longitudinal axis, as in existent formulations. Moreover, a linear strain variation mode is provided for the geometric non-linear approach, for which complete 3D constitutive relation (Saint-Venant Kirchhoff) is adopted. The proposed technique allows the consideration of inhomogeneous cross-sections with any geometry. Various examples are shown to demonstrate the accuracy and applicability of the proposed formulation. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this paper is to provide and verify simplified models that predict the longitudinal stresses that develop in C-section purlins in uplift. The paper begins with the simple case of flexural stress: where the force has to be applied at the shear center, or the section braced in both flanges. Restrictions on load application point and restraint of the flanges are removed until arriving at the more complex problem of bending when movement of the tension flange alone is restricted, as commonly found in purlin-sheeting systems. Winter`s model for predicting the longitudinal stresses developed due to direct torsion is reviewed, verified, and then extended to cover the case of a bending member with tension flange restraint. The developed longitudinal stresses from flexure and restrained torsion are used to assess the elastic stability behavior of typical purlin-sheeting systems. Finally, strength predictions of typical C-section purlins are provided for existing AISI methods and a newly proposed extension to the direct strength method that employs the predicted longitudinal stress distributions within the strength prediction. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The trapezium is often a better approximation for the FinFET cross-section shape, rather than the design-intended rectangle. The frequent width variations along the vertical direction, caused by the etching process that is used for fin definition, may imply in inclined sidewalls and the inclination angles can vary in a significant range. These geometric variations may cause some important changes in the device electrical characteristics. This work analyzes the influence of the FinFET sidewall inclination angle on some relevant parameters for analog design, such as threshold voltage, output conductance, transconductance, intrinsic voltage gain (A V), gate capacitance and unit-gain frequency, through 3D numeric simulation. The intrinsic gain is affected by alterations in transconductance and output conductance. The results show that both parameters depend on the shape, but in different ways. Transconductance depends mainly on the sidewall inclination angle and the fixed average fin width, whereas the output conductance depends mainly on the average fin width and is weakly dependent on the sidewall inclination angle. The simulation results also show that higher voltage gains are obtained for smaller average fin widths with inclination angles that correspond to inverted trapeziums, i.e. for shapes where the channel width is larger at the top than at the transistor base because of the higher attained transconductance. When the channel top is thinner than the base, the transconductance degradation affects the intrinsic voltage gain. The total gate capacitances also present behavior dependent on the sidewall angle, with higher values for inverted trapezium shapes and, as a consequence, lower unit-gain frequencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The taxonomic composition and diversity of assemblages of Ephemeroptera nymphs of four lotic environments in the central region of State of Rio Grande do Sul, a subtropical area in southern Brazil, were evaluated. Samplings were done monthly, with a Surber sampler, from June 2001 to May 2002, in the Jacui River and three of its tributaries. The total number of nymphs collected in the four sampling sites was 11,007 in five families and 19 genera, of these, 11 are new records for the State. The highest diversity occurred in Point 4 (H` = 2.41) and the lowest in Point 2 (H` = 1.69). Point 4 had the highest environmental stability, conservation of the riparian vegetation and the lowest anthropic impact, while Point 2 presented a large environmental simplification due to a direct anthropic influence ( e. g. domestic sewerage, trampling by cattle). The diversity of nymphs observed in the total area is high, compared to the estimated maximum theoretical diversity; a result of the high evenness and richness recorded. Rarefaction curves, calculated for a sample of 1,018 specimens, showed a similar expectation of richness for the four sampling sites. This result seems to be associated with the overall environmental homogeneity of the region caused by long-term alterations ( land use and deforestation). In summary, higher diversity of Ephemeroptera nymph assemblages seems to be associated with habitat complexity, a good vegetation cover and a lower anthropic influence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The purpose of this study was to describe the preliminary results of prophylactic temporary balloon occlusion of the internal iliac arteries for bleeding control in patients with placenta accreta during cesarean hysterectomy. Methods From May 2006 to March 2010, 21 patients diagnosed with placenta accreta using ultrasound and/or magnetic resonance imaging were submitted to prophylactic balloon occlusion before hysterectomy. Fluoroscopy, balloon occlusion time, surgical duration, intraoperative blood loss, transfusion volume, and procedure complications were analyzed. Results The mean age was 30.5 years with a mean of 3.6 previous gestations. Imaging studies revealed that all patients had placenta accreta and all were submitted to cesarean hysterectomy. One hysterectomy was due to previous diagnosis of fetal death and another due to cesarean with uterine curettage. Mean fluoroscopy time was 7.5 min, balloon occlusion time was 164 min, and surgery duration was 260 min. Estimated blood loss was 1,671.5 ml with mean reposition fluids of 3,538 ml of crystalloids, 309.5 ml of colloids, and 1.24 ml of packed red blood cells. Two patients were submitted to thromboembolectomy due to prolonged surgical time. There was no maternal or fetal mortality related to the procedure. Conclusions The results demonstrated that prophylactic balloon occlusion of internal iliac artery is a safe method and appears to reduce blood loss and transfusion requirements in patients diagnosed with placenta accreta who undergo cesarean hysterectomy. Antenatal imaging diagnosis of placenta accreta enables preoperative planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nani FS, Torres MLA - Correlation between the Body Mass Index (BMI) of Pregnant Women and the Development of Hypotension after Spinal Anesthesia for Cesarean Section. Background and objectives: Very few publications correlate hypotension in obese pregnant women, and especially morbidly obese, after spinal anesthesia for cesarean section. The objective of the present study was to evaluate the incidence of hypotension according to the BMI. Methods: Forty-nine patients with pregestational BMI below 25 kg.m(-2) were included in the Eutrophia group, and 51 patients with BMI >= 25 kg.m(-2) were included in the Overweight group. After spinal anesthesia, blood pressure, volume of crystalloid infused, and dose of vasopressors used until delivery were recorded. A fall in systolic blood pressure below 100 mmHg or 10% reduction of the initial systolic blood pressure (SBP) was considered as hypotension and it was corrected by the administration of vasopressors. Results: Episodes of hypotension were fewer in the Eutrophia group (5.89 +/- 0.53 vs. 7.80 +/- 0.66, p = 0.027), as well as the amount of crystalloid administered (1,298 +/- 413.6 mL vs. 1,539 +/- 460.0 mL; p = 0.007), and use of vasopressors (5.87 +/- 3.45 bolus vs. 7.70 +/- 4.46 bolus; p = 0.023). As for associated diseases, we observed higher incidence of diabetes among obese pregnant women (29.41% vs. 9.76%, RR 1.60, 95%CI: 1.15-2.22, p = 0.036), however, differences in the incidence of pregnancy-induced hypertension (PIN) were not observe between both groups (overweight: 21.57%, normal weight: 12.20%, RR 1.30, 95%CI: 0.88-1.94, p = 0.28). Conclusions: In the study sample, pregestational BMI >= 25 kg.m(-2) was a risk factor for hypotension after spinal anesthesia in patients undergoing cesarean section. The same group of patients required higher doses of vasopressors. Those results indicate that the anesthetic techniques in those patients should be improved to reduce the consequences of post-spinal anesthesia hypotension, both in pregnant women and fetuses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bliacheriene F, Carmona MJC, Barretti CFM, Haddad CMF, Mouchalwat ES, Bortlotto MRFL, Francisco RPV, Zugaib M - Use of a Minimally Invasive Uncalibrated Cardiac Output Monitor in Patients Undergoing Cesarean Section under Spinal Anesthesia: Report of Four Cases. Background and Objectives: Hemodynamic changes are observed during cesarean section under spinal anesthesia. Non-invasive blood pressure (BP) and heart rate (HR) measurements are performed to diagnose these changes, but they are delayed and inaccurate. Other monitors such as filling pressure and cardiac output (CO) catheters with external calibration are very invasive or inaccurate. The objective of the present study was to report the cardiac output measurements obtained with a minimally invasive uncalibrated monitor (LiDCO rapid) in patients undergoing cesarean section under spinal anesthesia. Case report: After approval by the Ethics Commission, four patients agreed to participate in this study. They underwent cesarean section under spinal anesthesia while at the same time being connected to the LiDCO rapid by a radial artery line. Cardiac output, HR, and BP were recorded at baseline, after spinal anesthesia, after fetal and placental extraction, and after the infusion of oxytocin and metaraminol. We observed a fall in BP with an increase of HR and CO after spinal anesthesia and oxytocin infusion; and an increase in BP with a fall in HR and CO after bolus of the vasopressor. Conclusions: Although this monitor had not been calibrated, it showed a tendency for consistent hemodynamic data in obstetric patients and it may be used as a therapeutic guide or experimental tool.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atelectasis after either vaginal or Caesarean delivery has not been adequately quantified. This study addresses the hypothesis that atelectasis may be worse in women who undergo Caesarean section when compared with vaginal delivery under regional anaesthesia. Twenty healthy non-smoking women submitted to a chest computed tomography (CT) 2 h after delivery in a University Hospital, who had experienced vaginal delivery (n=10) under combined spinal-epidural analgesia or a Caesarean section (n=10) under spinal anaesthesia, were evaluated. The percentage cross-sectional area of atelectasis in dependent lung regions were measured from the CT images obtained at cross-section of the xiphoid process and the top of the diaphragm. The percentage cross-sectional area of atelectasis was 3.95% in the vaginal delivery group and 14.1% in the Caesarean group (P < 0.001, Mann-Whitney rank sum test). These results suggested that pulmonary atelectasis is greater after Caesarean section delivery under spinal anaesthesia than after vaginal delivery with combined spinal-epidural analgesia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Golgi method has been used for over a century to describe the general morphology of neurons in the nervous system of different species. The ""single-section"" Golgi method of Gabbott and Somogyi (1984) and the modifications made by Izzo et al. (1987) are able to produce consistent results. Here, we describe procedures to show cortical and subcortical neurons of human brains immersed in formalin for months or even years. The tissue was sliced with a vibratome, post-fixed in a combination of paraformaldehyde and picric acid in phosphate buffer, followed by osmium tetroxide and potassium dicromate, ""sandwiched"" between cover slips, and immersed in silver nitrate. The whole procedure takes between 5 and 11 days to achieve good results. The Golgi method has its characteristic pitfalls but, with this procedure, neurons and glia appear well-impregnated, allowing qualitative and quantitative studies under light microscopy. This contribution adds to the basic techniques for the study of human nervous tissue with the same advantages described for the ""single-section"" Golgi method in other species; it is easy and fast, requires minimal equipment, and provides consistent results. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To compare pelvic floor muscle (PFM) strength between women undergoing vaginal delivery, cesarean section, and nulliparae, investigating the factors associated with PFM strength, and observing the correlation between vaginal digital palpation and use of a perineometer. Methods. A cross-sectional study was conducted, including 31 women following vaginal delivery, 30 women following cesarean section, and 30 nulliparous women. PFM strength was measured by vaginal digital palpation and use of a perineometer. Multiple linear regression analysis with adjustment for covariables was used to compare the mean PFM strength and identify its associated factors. Results. The mean PFM strength of women undergoing vaginal delivery and cesarean section was 25.6 +/- 14.5 cmH(2)O and 39.6 +/- 22.0 cmH(2)O (p < 0.01, adjusted for covariables), respectively. A correlation was observed between measurements of PFM strength obtained by vaginal digital palpation and use of a perineometer (tau = 0.82; p < 0.01). The non-white race/ethnicity was negatively associated with PFM strength (coefficient: -10.2424; p = 0.02). Conclusions. A lower PFM strength was observed in women with a history of vaginal delivery compared to those undergoing cesarean section. Non-white race/ethnicity negatively affected PFM strength. Our data suggest that vaginal digital palpation may be used in clinical practice because of its expressive correlation with use of a perineometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the reliability of two- and three-dimensional ultrasonographic measurement of the thickness of the lower uterine segment (LUS) in pregnant women by transvaginal and transabdominal approaches. Methods This was a study of 30 pregnant women who bad bad at least one previous Cesarean section and were between 36 and 39 weeks` gestation, with singleton pregnancies in cephalic presentation. Sonographic examinations were performed by two observers using both 4-7-MHz transabdominal and 5-8-MHz transvaginal volumetric probes. LUS measurements were performed using two- and three-dimensional ultrasound, evaluating the entire LUS thickness transabdominally and the LUS muscular thickness transvaginally. Each observer measured the LUS four times by each method. Reliability was analyzed by comparing the mean of the absolute differences, the intraclass correlation coefficients, the 95% limits of agreement and the proportion of differences <1 mm. Results Transvaginal ultrasound provided greater reliability in LUS measurements than did transabdominal ultrasound. The use of three-dimensional ultrasound improved significantly the reliability of the LUS muscular thickness measurement obtained transvaginally. Conclusions Ultrasonographic measurement of the LUS muscular thickness transvaginally appears more reliable than does that of the entire LUS thickness transabdominally. The use of three-dimensional ultrasound should be considered to improve measurement reliability. Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.