117 resultados para Rhythmic Movements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kallmann syndrome (KS), characterized by the association of hypogonadotropic hypogonadism and anosmia, may present many other phenotypic abnormalities, including neurologic features as involuntary movements, called mirror movements (MM). MM etiology probably involves a complex mechanism comprising corticospinal tract abnormal development associated with deficient contralateral motor cortex inhibitory system. In this study, in order to address previous hypotheses concerning MM etiology, we identified and quantified white matter (WM) alterations in 21 KS patients, comparing subjects with and without MM and 16 control subjects, using magnetization transfer ratio (MTR) and T2 relaxometry (R2). Magnetization transfer and 12 double-echo images were acquired in a 1.5 T system. MTR and R2 were calculated pixel by pixel to initially create individual maps, and then, group average maps, co-registered with MNI305 stereotaxic coordinate system. After analysis of selected regions of interest, we demonstrated areas with higher 12 relaxation time and lower MTR values in KS patients, with and without MM, differently involving corticospinal tract projection, frontal lobes and corpus callosum. Higher MTR was observed only in pyramidal decussation when compared in both groups of patients with controls. In conclusion, we demonstrated that patients with KS have altered WM areas, presenting in a different manner in patients with and without MM. These data suggest axonal loss or disorganization involving abnormal pyramidal tracts and other associative/connective areas, relating to the presence or absence of MM. We also found a different pattern of alteration in pyramidal decussation, which can represent the primary area of neuronal disarrangement. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Saccades are part of the electrooculography tests battery. The cerebellum has important connections with the brainstem and thalamic structures involved in the generation of saccades. Aim: to study saccadic movements in subjects with cerebellar disorders. Study Method: Prospective clinical study. Materials and Methods: 11 subjects with cerebellar disorders were selected, together with a control group with 27 normal subjects. The patients of both groups had their saccadic movements registered (fixed and randomized). We compared and quantitatively analyzed the responses from both groups. Results: We did not find any differences among the quantitative parameters between the two. Age and gender did not influence these values. Despite these findings, the morphologies of the saccadic curves were very different between the two groups. Conclusion: Quantitative parameters of horizontal saccades from individuals with cerebellar diseases do not differ from those presented by normal subjects. Gender and age also did not influence these parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To establish the relationship between upper eyelid saccades and upper eyelid pursuit movements. METHODS. Upper eyelid saccades and periodic sinusoidal upper eyelid pursuit movements were recorded in a sample of controls and patients with Graves upper eyelid retraction. A video-computerized system was used to register both types of movements that accompanied 60 of eye rotation across the upper and lower hemifields. The forced harmonic oscillator model was used to fit saccadic and pursuit movements. RESULTS. Mean mid-pupil eyelid distance for the Graves patients (6.6 +/- 1.1 mm) was significantly higher than for the controls (4.6 +/- 0.8 mm; t = 7.18; P < 0.00001). Despite the difference in the upper eyelid resting position, saccades and pursuit eyelid movements of both groups were extremely well fitted by underdamped solutions and steady forced solutions of the harmonic oscillator model, respectively. For the controls, the amplitude of the pursuit movements was well correlated with the upward and downward saccades. The amplitude of the eyelid movements of the Graves patients (saccades and pursuit) was significantly reduced compared with that of the controls. CONCLUSIONS. Saccadic and pursuit movements of the upper eyelid can be described by the harmonic oscillator model. In healthy subjects and Graves patients, the amplitude of pursuit lid movements is correlated to the saccade amplitude. Pursuit eyelid movements are more difficult to register than saccades, and their measurements do not allow clear separation of the relaxation and contraction properties of the upper eyelid retractors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ESTEVES, A. M., M. T. DE MELLO, M. PRADELLA-HALLINAN, and S. TUFIK. Effect of Acute and Chronic Physical Exercise on Patients with Periodic Leg Movements. Med. Sci. Sports Exerc., Vol. 41, No. 1,. pp. 237-242, 2009. Purpose: Nonpharmacological interventions may lead to an improvement in sleep quality. The objective of our study was to evaluate the effects of acute intensive exercise and chronic exercise on sleep patterns in patients with periodic leg movements (PLM). Methods: The study involved acute and chronic exercise. The acute intensive exercise group consisted of 22 volunteers who underwent a maximum effort test and a polysomnography (PSG) on the same night. The chronic exercise group included. 11 patients who performed 72 physical training sessions undergoing three PSG studies on the night of sessions 1, 36, and 72. Blood samples were collected from both acute and chronic groups for beta-endorphin dosage. Results: Our results showed that both forms of physical exercise lowered PLM levels. The acute physical exercise increased sleep efficiency, rapid eye movement (REM) sleep, and reduced wake after sleep onset, whereas the chronic physical exercise increased sleep efficiency, REM sleep, and reduced sleep latency. We also found a significant negative correlation between beta-endorphin release after acute intensive exercise and PLM levels (r = -0.63). Conclusion: Physical exercise may improve sleep patterns and reduce PLM levels. The correlation between beta-endorphin release after acute intensive exercise and PLM levels might be associated with the impact physical exercise has on the opiodergic system. We suggest that physical exercise may be a useful nonpharmacological treatment for PLM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To test for an association between rhythmic masticatory muscle activity during sleep, as assessed according to polysomnographic criteria for sleep bruxism (RMMA-SB), and myofascial pain (MFP), as well as the chance of occurrence of MFP in patients with RMMA-SB. Methods: Thirty MFP patients (diagnosed according to the Research Diagnostic Criteria for Temporomandibular Disorders) and 30 age- and gender-matcbed asymptomatic controls underwent a polysomnographic examination. Also, any self-reporting of daytime clenching (DC) was registered in 58 of these subjects. Results: Most MFP patients reported mild or moderate pain (46.67% and 43.33%, respectively), and only 3 (10%) reported severe pain. Pain duration ranged from 2 to 120 months (mean 34.67 +/- 36.96 months). Significant associations were observed between RMMA-SB and MFP as well as between DC and MFP. Conclusions: (1) RMMA-SB is significantly associated with MFP; (2) although RMMA-SB represents a risk factor for MFP, this risk is low; and (3) DC probably constitutes a stronger risk factor for MFP than RMMA-SB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ecological studies of movements in animals require extensive knowledge of direction, distance and frequency of movements. The purpose of this study was to describe the daily and seasonal movements in a population of the South American rattlesnake, Crotalus durissus. The study population inhabits a cerrado area in southeastern Brazil. Snakes were tracked with externally attached radio-transmitters and thread bobbins. Larger animals tended to make more extensive daily movements, moving further from the initial site of capture. There were no differences in average daily movements between sexes. Site fidelity was higher in the dry season for both sexes. Both sexes moved distances twice as long as those calculated by drawing a straight line between consecutive points. The movement pattern of C. durissus seemed to be similar to that observed in other tropical pit vipers, such as species of the genus Bothrops.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Edge effects are suggested to have great impact on the persistence of species in fragmented landscapes. We tested edge avoidance by forest understory passerines in the Brazilian Atlantic Rainforest and also compared their mobility and movement patterns in contiguous and fragmented landscapes to assess whether movements would increase in the fragmented landscape. Between 2003 and 2005, 96 Chiroxiphia caudata, 38 Pyriglena leucoptera and 27 Sclerurus scansor were radio-tracked. The most strictly forest species C. caudata and S scansor avoided forest edges while P leucoptera showed affinities for the edge Both sensitive species showed larger mean step length and maximal observed daily distance in the fragmented forest versus the unfragmented forest. P. leucoptera did not show any significant difference. There were no significant differences in proportional daily home range use for any of the three species. Our results suggested that fragmentation and the consequent increase in edge areas do influence movement behavior of sensitive forest understory birds that avoided the use of edges and increased the speed and distance they covered daily. For the most restricted forest species, it would be advisable to protect larger patches of forest instead of many small or medium fragments connected by narrow corridors. However, by comparing our data with that obtained earlier, we concluded that movement behavior of resident birds differs from that of dispersing birds and might not allow to infer functional connectivity or landscape-scale sensitivity to fragmentation; a fact that should be taken into consideration when suggesting conservation strategies. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The avian circadian system is composed of the retina, the mammalian homolog region of the suprachiasmatic nucleus (SNC), and the pineal gland. The retina, itself, displays many rhythmic physiological events, such as movements of photoreceptor cells, opsin expression, retinal reisomerization, and melatonin and dopamine production and secretion. Altogether, these rhythmic events are coordinated to predict environmental changes in light conditions during the day, optimizing retina function. The authors investigated the expression pattern of the melanopsin genes Opn4x and Opn4m, the clock genes Clock and Per2, and the genes for the key enzymes N-Acetyltransferase and Tyrosine Hidroxylase in chicken embryo dispersed retinal cells. Primary cultures of chicken retina from 8-day-old embryos were kept in constant dark (DD), in 12-h light/12-h dark (12L:12D), in 12L:12D followed by DD, or in DD in the absence or presence of 100 mu M glutamate for 12 h. Total RNA was extracted throughout a 24-h span, every 3 h starting at zeitgeber time 0 (ZT0) of the 6th day, and submitted to reverse transcriptase-polymerase chain reaction (RT-PCR) followed by quantitative PCR (qPCR) for mRNA quantification. The data showed no rhythmic pattern of transcription for any gene in cells kept in DD. However under a light-dark cycle, Clock, Per2, Opn4m, N-Acetyltransferase, and Tyrosine Hydroxylase exhibited rhythmic patterns of transcription. In DD, 100 mu M glutamate was able to induce rhythmic expression of Clock, strongly inhibited the expression of Tyrosine Hydroxylase, and, only at some ZTs, of Opn4x and Opn4m. The neurotransmitter had no effect on Per2 and N-Acetyltransferase transcription. The authors confirmed the expression of the protein OPN4x by immunocytochemistry. These results suggest that chicken embryonic retinal cells contain a functional circadian clock, whose synchronization requires light-dark cycle or glutamate stimuli. (Author correspondence: amdlcast@ib.usp.br).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We quantified gait and stride characteristics (velocity, frequency, stride length, stance and swing duration, and duty factor) in the bursts of locomotion of two small, intermittently moving, closely related South American gymnophthalmid lizards: Vanzosaura rubricauda and Procellosaurinus tetradactylus. They occur in different environments: V rubricauda is widely distributed in open areas with various habitats and substrates, while P. tetradactylus is endemic to dunes in the semi-arid Brazilian Caatinga. Both use trot or walking trot characterised by a lateral sequence. For various substrates in a gradient of roughness (perspex, cardboard, sand, gravel), both species have low relative velocities in comparison with those reported for larger continuously moving lizards. To generate velocity, these animals increase stride frequency but decrease relative stride length. For these parameters, P. tetradactylus showed lower values than V rubricauda. In their relative range of velocities, no significant differences in stride length and frequency were recorded for gravel. However, the slopes of a correlation between velocity and its components were lower in P. tetradactylus on cardboard, whereas on sand this was only observed for velocity and stride length. The data showed that the difference in rhythmic parameters between both species increased with the smoothness of the substrates. Moreover, P. tetradactylus shows a highly specialised locomotor strategy involving lower stride length and frequency for generating lower velocities than in V. rubricauda. This suggests the evolution of a central motor pattern generator to control slower limb movements and to produce fewer and longer pauses in intermittent locomotion. (c) 2008 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mandibular movements occur through the triggering of trigeminal motoneurons. Aberrant movements by orofacial muscles are characteristic of orofacial motor disorders, such as nocturnal bruxism (clenching or grinding of the dentition during sleep). Previous studies have suggested that autonomic changes occur during bruxism episodes. Although it is known that emotional responses increase jaw movement, the brain pathways linking forebrain limbic nuclei and the trigeminal motor nucleus remain unclear. Here we show that neurons in the lateral hypothalamic area, in the central nucleus of the amygdala, and in the parasubthalamic nucleus, project to the trigeminal motor nucleus or to reticular regions around the motor nucleus (Regio h) and in the mesencephalic trigeminal nucleus. We observed orexin co-expression in neurons projecting from the lateral hypothalamic area to the trigeminal motor nucleus. In the central nucleus of the amygdala, neurons projecting to the trigeminal motor nucleus are innervated by corticotrophin-releasing factor immunoreactive fibers. We also observed that the mesencephalic trigeminal nucleus receives dense innervation from orexin and corticotrophin-releasing factor immunoreactive fibers. Therefore, forebrain nuclei related to autonomic control and stress responses might influence the activity of trigeminal motor neurons and consequently play a role in the physiopathology of nocturnal bruxism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article reports the case of a 19-year-old young man with Class III malocclusion and posterior crossbite with concerns about temporomandibular disorder (TMD), esthetics and functional problems. Surgical-orthodontic treatment was carried out by decompensation of the mandibular incisors and segmentation of the maxilla in 4 pieces, which allowed expansion and advancement. Remission of the signs and symptoms occurred after surgical-orthodontic intervention. The maxillary dental arch presented normal transverse dimension. Satisfactory static and functional occlusion and esthetic results were achieved and remained stable. Three years after the surgical-orthodontic treatment, no TMD sign or symptom was observed and the occlusal results had not changed. When vertical or horizontal movements of the maxilla in the presence of moderate maxillary constriction are necessary, segmental LeFort I osteotomy can be an important part of treatment planning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: esta pesquisa objetivou avaliar cefalometricamente as alterações dentoesqueléticas de jovens com Classe II dentária tratados com o distalizador Jones jig. METODOLOGIA: foram avaliados 30 pacientes, sendo 15 de cada gênero, com média de idades iniciais de 13,63 anos; brasileiros, naturais da cidade de Bauru/SP, caracterizados por má oclusão de Classe II, 1ª e 2ª divisões de Angle sem comprometimento esquelético. Os jovens foram tratados com aparelho Jones jig a fim de distalizar os molares superiores a uma relação molar de "super Classe I"; sendo que esse dispositivo permaneceu, em média, por 0,55 anos. Ao final da sobrecorreção, os molares distalizados receberam um botão de Nance e, como ancoragem extrabucal, o aparelho extrabucal (AEB) com tração média-alta, com o intuito de verticalizar e corrigir a angulação radicular dos molares distalizados. Foram realizadas telerradiografias em normal lateral inicial (T1) e pós-distalização (T2). As medidas cefalométricas foram submetidas ao teste t dependente de Student para avaliar as alterações de T1 para T2. RESULTADOS: com base nos resultados obtidos e a partir da metodologia empregada, observou-se alterações dentárias significativas, como a movimentação distal linear e angular, assim como a intrusão dos segundos e primeiros molares superiores no sentido vertical. Também se confirmou efeitos indesejáveis, como a perda de ancoragem refletida em mesialização, extrusão e angulação mesial dos segundos pré-molares, a protrusão dos incisivos superiores e o aumento do trespasse vertical e horizontal. Pode-se confirmar que certas movimentações dentárias promovem significativas alterações esqueléticas de estruturas localizadas à distância, ou seja, observou-se extrusão significativa dos segundos pré-molares superiores, o que resultou em rotação mandibular, aumento significativo da altura facial anteroinferior e protrusão do lábio inferior. CONCLUSÃO: pode-se concluir que o distalizador Jones jig promove, basicamente, alterações dentárias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports a rare case of acute severe orbital abscess manifested 2 days after a facial trauma without bone fracture in a 20-year-old Afro-American female. The symptoms worsened within the 24 h prior to hospital admission resulting in visual disturbances such as diplopia and photophobia. The clinical findings at the first consultation included fever, periorbital swelling and redness, ptosis, proptosis and limitation of ocular movements upwards, downwards, to the right and to the left. Computed tomography scan showed proptosis with considerable soft tissue swelling on the left side and no fracture was evidenced in the facial skeleton, including the zygomatic-orbital complex. After hospital admission and antibiotic therapy intravenously the patient was conducted to the operation room and submitted to incision and drainage under general anesthesia. The orbit was approached thorough both eyelids and the maxillary sinus was reached only through the Caldwell-Luc approach. The postoperative period was uneventful and the rapid improvement of symptoms was remarkable. Visual acuity and ocular motility returned to the normal ranges within 2 days after the surgical intervention. After 12 postoperative days, the patient presented with significative improvement in the ptosis and proptosis, and acceptable scars.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cleaning capacity of Hero 642 nickel-titanium files, complemented by the Hero Apical instruments in flattened roots, was determined by histological analysis, considering the area of action of the instruments on the coronal walls and the presence of remaining debris. Twenty-four single-canal, human mandibular incisors were divided into three groups and prepared as follows: GI, instrumented with Hero 642 NiTi files 30/.06, 25/.06, 20/.06, 25/.06, and 30/.06; GII, instrumented as GI followed by Hero Apical size 30/.06; GIII, instrumented as GI followed by Hero Apical sizes 30/.06 and 30/.08, then returning to 30/.06 with pendulum movements. The apical thirds were prepared for histological processing, analyzed at 40× magnification and the images were examined morphometrically. Statistical analysis showed that GIII presented the best results for removing debris (5.22% ± 4.13), with more contact between the instruments and the root canal walls (19.31% ± 0.15). This differed statistically from GI (14.04% ± 4.96 debris removal, with 42.96% ± 7.11 instrument contact) and GII (12.62% ± 5.76 debris removal, with 35.01% ± 0.15 instrument contact). Root canal preparation with Hero 642, complemented by Hero Apical instruments (30/.06 and 30/.08, then re-instrumented with Hero Apical 30/.06 using pendulum movements), was more efficient for debris removal and allowed more contact of the instruments with the root canal walls. GII presented the worst results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Temporomandibular joint (TMJ) sounds are important and common physical signs of temporomandibular disorders (TMD). The aim of this study was to evaluate the influence of the effect of the use of occlusal bite splints (stabilizing and repositioning) on the sounds produced in the TMJ, by means of the electrovibratography (EVG). Thirty-one patients with TMD from the Dental School of Ribeirão Preto, University of São Paulo, Brazil were selected for this study. Group 1 (n=23) wore stabilizing bite splints and Group 2 (n=8) used anterior repositioning splints. Before and after treatment with occlusal splints both groups were analyzed using the SonoPAK Q/S recording system (BioResearch System, Inc.). The treatments with stabilizing bite splints were satisfactory, since they reduced the total amount of the sound energies (p<0.05), but the use of anterior repositioning splints for no more than 4 weeks produced significantly better results (p<0.01). The total amount of vibration energy involved in the vibrating movements of the TMJ showed significant improvement using anterior repositioning splints.