497 resultados para Loikala, Paula: Grammatica finlandese


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chemical substances used during biomechanical preparation of root canals can alter the composition of dentin surface and affect the interaction with restorative materials. OBJECTIVE: The purpose of this study was to evaluate the microtensile bond strength (µTBS) of a self-etching adhesive system to dentin irrigated with sodium hypochlorite (NaOCl) and ethylenediaminetetraacetic acid (EDTA). MATERIAL AND METHODS: Thirty human third molars were sectioned 3 mm below the occlusal surface, polished with 600- to 1200-grit silicon carbide papers, and randomly divided into 3 groups: G1 (control): no irrigating solution; G2: 1% NaOCl; and G3: 1% NaOCl followed by the application of 17% EDTA. The specimens received the self-etching adhesive system (XENO III - Dentsply), restored with microhybrid composite resin (Z250 - 3M ESPE), sectioned and trimmed to create 4 hourglass-shaped slabs of each tooth. The slabs were tested in microtensile strength in a universal testing machine (Emic DL 2000) at a crosshead speed of 0.5 mm/min until fracture. The results were analyzed statistically by ANOVA and Newman-Keuls test. RESULTS: Mean µTBS values and standard deviations in MPa were: G1 = 11.89 ± 4.22; G2 = 19.41 ± 5.32; G3 = 11.34 ± 4.73. 1% NaOCl increased the adhesive resistance significantly (p<0.001/F=22.5763). The application of 1% NaOCl/17% EDTA resulted in statistically similar µTBS to the control group. CONCLUSIONS: None of the irrigants affected negatively the µTBS of XENO III to dentin. The use of 1% NaOCl alone resulted in higher bond strength than the other treatments. The combination of 1% NaOCl and 17% EDTA produced similar bond strength to that of untreated dentin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to evaluate the morphology of glass (GF), carbon (CF) and glass/carbon (G/CF) fiber posts and their bond strength to self or dual-cured resin luting agents. MATERIAL AND METHODS: Morphological analysis of each post type was conducted under scanning electron microscopy (SEM). Bond strength was evaluated by microtensile test after bisecting the posts and re-bonding the two halves with the luting agents. Data were subjected to two-way ANOVA and Tukey's test (α=0.05). Failure modes were evaluated under optical microscopy and SEM. RESULTS: GF presented wider fibers and higher amount of matrix than CF, and G/CF presented carbon fibers surrounded by glass fibers, and both involved by matrix. For CF and GF, the dual-cured material presented significantly higher (p<0.05) bond strength than the self-cured agent. For the dual agent, CF presented similar bond strength to GF (p>0.05), but higher than that of G/CF (p<0.05). For the self-cured agent, no significant differences (p>0.05) were detected, irrespective of the post type. For GF and G/CF, all failures were considered mixed, while a predominance of adhesive failures was detected for CF. CONCLUSION: The bonding between fiber posts and luting agents was affected by the type of fibers and polymerization mode of the cement. When no surface treatment of the post is performed, the bonding between glass fiber post and dual-cured agent seems to be more reliable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because a greater research effort has been directed to analyzing the adhesive effectiveness of self etch primers to dentin, the aim of this study was to evaluate, by microtensile testing, the bond strength to enamel of a composite resin combined with a conventional adhesive system or with a self-etching primer adhesive, used according to its original prescription or used with previous acid etching. Thirty bovine teeth were divided into 3 groups with 10 teeth each (n= 10). In one of the groups, a self-etching primer (Clearfil SE Bond - Kuraray) was applied in accordance with the manufacturer's instructions and, in the other, it was applied after previous acid etching. In the third group, a conventional adhesive system (Scotchbond Multipurpose Plus - 3M-ESPE) was applied in accordance with the manufacturer's instructions. The results obtained by analysis of variance revealed significant differences between the adhesive systems (F = 22.31). The self-etching primer (Clearfil SE Bond) presented lower enamel bond strength values than the conventional adhesive system (Scotchbond Multipurpose Plus) (m = 39.70 ± 7.07 MPa) both when used according to the original prescription (m = 27.81 ± 2.64 MPa) and with previous acid etching (m = 25.08 ± 4.92 MPa).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Studies have shown the cariostatic effect of Er,Cr:YSGG (2.78 mm) laser irradiation on human enamel and have suggested its use on caries prevention. However there are still no reports on the intrapulpal temperature increase during enamel irradiation using parameters for caries prevention. The aim of this in vitro study was to evaluate the temperature variation in the pulp chamber during human enamel irradiation with Er,Cr:YSGG laser at different energy densities. Fifteen enamel blocks obtained from third molars (3 x 3 x 3 mm) were randomly assigned to 3 groups (n=5): G1 - Er,Cr:YSGG laser 0.25 W, 20 Hz, 2.84 J/cm², G2 - Er,Cr:YSGG laser 0.50 W, 20 Hz, 5.68 J/cm², G3 - Er,Cr:YSGG laser 0.75 W, 20 Hz, 8.52 J/cm². During enamel irradiation, two thermocouples were fixed in the inner surface of the specimens and a thermal conducting paste was used. One-way ANOVA did not show statistically significant difference among the experimental groups (a=0.05). There was intrapulpal temperature variation <0.1ºC for all irradiation parameters. In conclusion, under the tested conditions, the use of Er,Cr:YSGG laser with parameters set for caries prevention lead to an acceptable temperature increase in the pulp chamber.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: avaliar características clínicas, patológicas e moleculares de carcinomas mamários em mulheres muito jovens em comparação a tumores de mulheres na pós-menopausa. MÉTODOS: foram selecionados 106 casos de câncer de mama de mulheres jovens e 130 casos de mulheres pós-menopausa. Foram analisados dados clínicos (idade ao diagnóstico, estadiamento, ocorrência de metástases, tempo de sobrevida global e livre de doença), anátomo-patológicos (tamanho do tumor, tipo e grau histológico do tumor primário) e marcadores moleculares (receptores de estrógeno e progesterona, HER2, p53, p63, citoqueratinas 5 e 14 e EGFR) com uso da imunoistoquímica empregando microarranjo de tecido. Foi analisada a relação entre as características clínico-patológicas, imunoistoquímicas e de sobrevidas global e livre de doença. RESULTADOS: as pacientes muito jovens apresentaram maior frequência de nuliparidade (p=0,03), maior diâmetro dos tumores (p<0,000), estadiamento clínico mais avançado (p=0,01), maior número de linfonodos positivos (p=0,001) e tumores pouco diferenciados (p=0,004). A maioria das pacientes jovens recebeu tratamento com quimioterapia (90,8%) e radioterapia (85,2%) e em menor proporção com tamoxifeno (31,5%), comparado às mulheres na pós-menopausa. Observamos baixa positividade para o receptor de estrógeno (49,1%; p=0,01) e alta positividade para a proteína HER2 (28,7%; p=0,03) nas mulheres jovens. O fenótipo triplo-negativo foi observado em 29,6% no grupo jovem e em 20% nas mulheres na pós-menopausa. Os tumores de fenótipo basal foram mais frequentes nas mulheres jovens (50%). As metástases sistêmicas ocorreram em 55,3% dos casos nas jovens e em 39,2% nas idosas. As sobrevidas global e livre de doença em cinco anos foram, respectivamente, 63 e 39% para as mulheres jovens e 75 e 67% para o grupo de mulheres na pós-menopausa. CONCLUSÕES: carcinomas mamários de mulheres muito jovens têm características clínicas, patológicas e moleculares mais agressivas quando comparadas às mulheres acima de 50 anos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the current study was to evaluate the sensitivity, specificity and accuracy of fine needle aspiration biopsy (FNAB) of submucous nodules from the oral cavity and head and neck region as an auxiliary diagnostic tool. Fifty patients with nodule lesions in the oral cavity and the head and neck region were selected. All of them were submitted to FNAB and to either incisional or excisional biopsy. The diagnoses from the FNABs were compared with the biopsy diagnosis as the gold standard. All the cases of FNAB were analyzed by a single oral pathologist prior to the biopsy diagnosis. The results showed that the sensitivity of FNAB was 75%, its specificity was 96% and its accuracy was 58.8%. The false positive and false negative rates were 6.7% and 13.3%, respectively. The positive predictive value was 86% and the negative predictive value was 93%. The inconclusive rate was 16/50. FNAB displayed a high success rate for identifying both malignant and benign lesions, but a low accuracy for making a final diagnosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report an uncommon case of osteochondroma affecting the mandibular condyle of a young patient and to illustrate the important contributions of different imaging resources to the diagnosis and treatment planning of this lesion. CASE DESCRIPTION: A 24-year-old female patient with the chief complaint of an increasing facial asymmetry and pain in the left pre-auricular region, revealing a reduced mouth opening, mandibular deviation and posterior cross-bite over a period of 18 months. Panoramic radiography revealed an enlargement of the left condyle, whereas computed tomography (CT) sections and three-dimensional CT showed a well-defined bone growth arising from condylar neck. The scintigraphy exam showed an abnormal osteogenic activity in the left temporomandibular joint. The condyle was surgically removed and after 18 months follow-up the panoramic radiography and CT scans showed no signs of recurrence. CONCLUSION: Although osteochondroma is a benign bone tumor that rarely arises in cranial and maxillofacial region, it should be considered in the differential diagnosis of slow-growing masses of the temporomandibular area and the use of different imaging exams significantly contribute to the correct diagnosis and treatment planning of this pathological condition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the increase in life expectancy, biomaterials have become an increasingly important focus of research because they are used to replace parts and functions of the human body, thus contributing to improved quality of life. In the development of new biomaterials, the Ti-15Mo alloy is particularly significant. In this study, the Ti-15Mo alloy was produced using an arc-melting furnace and then characterized by density, X-ray diffraction, optical microscopy, hardness and dynamic elasticity modulus measurements, and cytotoxicity tests. The microstructure was obtained with β predominance. Microhardness, elasticity modulus, and cytotoxicity testing results showed that this material has great potential for use as biomaterial, mainly in orthopedic applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: This study aimed to assess the survival and life quality evolution of patients subjected to surgical excision of oral and oropharyngeal squamous cell carcinoma. MATERIAL AND METHODS: Forty-seven patients treated at a Brazilian healthcare unit specialized in head and neck surgery between 2006 and 2007 were enrolled in the study. The gathering of data comprised reviewing hospital files and applying the University of Washington Quality of Life (UW-QOL) questionnaire previously and 1 year after the surgery. Comparative analysis used Poisson regression to assess factors associated with survival and a paired t-test to compare preoperative and 1-year postoperative QOL ratings. RESULTS: 1 year after surgery, 7 patients were not found (dropout of the cohort); 15 had died and 25 fulfilled the UW-QOL again. The risk of death was associated with having regional metastasis previously to surgery (relative risk=2.18; 95% confidence interval=1.09-5.17) and tumor size T3 or T4 (RR=2.30; 95%CI=1.05-5.04). Survivors presented significantly (p<0.05) poorer overall and domain-specific ratings of quality of life. Chewing presented the largest reduction: from 74.0 before surgery to 34.0 one year later. Anxiety was the only domain whose average rating increased (from 36.0 to 70.7). CONCLUSIONS: The prospective assessment of survival and quality of life may contribute to anticipate interventions aimed at reducing the incidence of functional limitations in patients with oral and oropharyngeal cancer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Secondary caries has been reported as the main reason for restoration replacement. The aim of this in vitro study was to evaluate the performance of different methods - visual inspection, laser fluorescence (DIAGNOdent), radiography and tactile examination - for secondary caries detection in primary molars restored with amalgam. Fifty-four primary molars were photographed and 73 suspect sites adjacent to amalgam restorations were selected. Two examiners evaluated independently these sites using all methods. Agreement between examiners was assessed by the Kappa test. To validate the methods, a caries-detector dye was used after restoration removal. The best cut-off points for the sample were found by a Receiver Operator Characteristic (ROC) analysis, and the area under the ROC curve (Az), and the sensitivity, specificity and accuracy of the methods were calculated for enamel (D2) and dentine (D3) thresholds. These parameters were found for each method and then compared by the McNemar test. The tactile examination and visual inspection presented the highest inter-examiner agreement for the D2 and D3 thresholds, respectively. The visual inspection also showed better performance than the other methods for both thresholds (Az = 0.861 and Az = 0.841, respectively). In conclusion, the visual inspection presented the best performance for detecting enamel and dentin secondary caries in primary teeth restored with amalgam.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to compare the completion rates and performance of the Brazilian version of the Oral Health Impact Profile (OHIP14) when applied as an interview or in its original self-reported form. A convenience sample of 74 adult patients was selected in a Dental Clinic (University of Araras, Brazil). One examiner administered the instrument in both formats to participants with an interval of 2 weeks between each administration. Data about dental health condition and socioeconomic status were collected and associated with total OHIP14 scores in both formats using linear regression analyses. No differences were found in the total scores and in each subscale of the OHIP14 according to the form of administration. Higher values of completion were found in the interview format. More severe impacts were recorded in the interview format than in the questionnaire format. Higher values of total OHIP-14 scores in both formats were related to the presence of dental caries. Total OHIP14 scores were not influenced by the method of administration. However, the use of the OHIP14 in the questionnaire format may result in lower completion rates and loss of data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the flexural strength (sf) and the diametral tensile strength (st) of light-cured composite resins, testing the hypothesis that there is a positive relation between these properties. Twenty specimens were fabricated for each material (Filtek Z250- 3M-Espe; AM- Amelogen, Ultradent; VE- Vit-l-escence, Ultradent; EX- Esthet-X, Dentsply/Caulk), following ISO 4049 and ANSI/ADA 27 specifications and the manufacturers’ instructions. For the st test, cylindrical shaped (4 mm x 6 mm) specimens (n = 10) were placed with their long axes perpendicular to the applied compressive load at a crosshead speed of 1.0 mm/min. The sf was measured using the 3-point bending test, in which bar shaped specimens (n = 10) were tested at a crosshead speed of 0.5 mm/min. Both tests were performed in a universal testing machine (EMIC 2000) recording the fracture load (N). Strength values (MPa) were calculated and statistically analyzed by ANOVA and Tukey (a = 0.05). The mean and standard deviation values (MPa) were Z250-45.06 ± 5.7; AM-35.61 ± 5.4; VE-34.45 ± 7.8; and EX-42.87 ± 6.6 for st; and Z250-126.52 ± 3.3; AM-87.75 ± 3.8; VE-104.66 ± 4.4; and EX-119.48 ± 2.1 for sf. EX and Z250 showed higher st and sf values than the other materials evaluated (p < 0.05), which followed a decreasing trend of mean values. The results confirmed the study hypothesis, showing a positive relation between the material properties examined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several characteristics are important in a traceability system of animal products, such as age at slaughter, breed composition, besides information of the productive chain. In general, the certification agent records information about the animals and the system which it came from, although cannot guarantee that the slaughtering, meat processing and distribution are error proof. Besides, there is a differential price, at least at the international market, based on sex and breed composition of the animals. Genetic markers allow identification of characteristics controlled in the beef cattle traceability program, as sex and breed composition, in order to correctly identify and appraise the final product for the consumer. The hypothesis of this study was that the majority beef samples retailed in the local market originate from female with a great participation of zebu breeds. Therefore, the objective of this work was to characterize retail beef samples with DNA markers that identify cattle sex and breed composition. Within 10 beef shops localized in Pirassununga, SP, Brazil, 61 samples were collected, all were genotyped as harboring Bos taurus mitochondrial DNA and 18 were positive for the Y chromosome amplification (male). For the marker sat1711b-Msp I the frequency of the allele A was 0.278 and for the marker Lhr-Hha I the frequency of the allele T was 0.417. The results of sat1711b-Msp I and Lhr-Hha I allelic frequencies are suggestive that the proportion of indicus genome compared with the taurine genome in the market meat is smaller than the observed in the Nellore breed. The procedure described in this study identified sex and subspecies characteristics of beef meat samples, with potential application in meat products certification in special as an auxiliary tool in beef cattle traceability programs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goals of this research were to estimate the phenotypic correlations among various meat quality traits from a male broiler line and to describe the relation among these variables. Phenotypical correlations were determined among quality traits, isolating the effects of slaughter date, the age of the mother and sex. The evaluated traits were pH measurements taken at time 0 and at 6 and 24 hours after slaughtering, color parameters, water loss due to exudation, thawing and cooking of the meat, and shear force. Important associations (P<0.01) were found to be significant and, in most cases, weak or moderate, varying from -0.35 to 0.28. The initial pH of the meat was not associated (P>0.05) to the other traits of the meat, whereas the pH at 24 hours after slaughter was able of directly interfering with the attributes of the meat, since this trait was inversely related with lightness and water losses, which indicates an effect of pH fall along 24h after slaughtering on protein denaturation. This study demonstrates that the variables of poultry meat quality are related and that there is a phenotypical association between lightness and cooking losses and the other attributes of the meat. The pH at 24 hours after slaughtering, lightness and cooking losses could be efficient meat quality indicators in this broiler line.