269 resultados para Human values


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although the cariostatic effects of CO(2) laser on enamel have been shown, its effects on root surface demineralization remains uncertain. The objectives of this in vitro research was to establish safe parameters for a pulsed 10.6 mu m CO(2) laser and to evaluate its effect on morphological features of the root surface, as well as on the reduction of root demineralization. Ninety-five human root surfaces were randomly divided into five groups: G1-No treatment (control); G2-2.5 J/cm(2); G3-4.0 J/cm(2); G4-5.0 J/cm(2); and G5-6.0 J/cm(2). Intrapulpal temperature was evaluated during root surface irradiation by a thermocouple and morphological changes were evaluated by SEM. After the surface treatment, the specimens were submitted to a 7-day pH-cycling model. Subsequently, the cross-sectional Knoop microhardness values were measured. For all irradiated groups, intrapulpal temperature changes were less than 1.5 degrees C. Scanning electron microscopy images indicated that fluences as low as 4.0 J/cm(2) were sufficient to induce morphological changes in the root surface. Additionally, for fluences reaching or exceeding 4.0 J/cm(2), laser-induced inhibitory effects on root surface demineralization were observed. It was concluded that laser energy density in the range of 4.0 to 6.0 J/cm(2) could be applied to a dental root to reduce demineralization of this surface without compromising pulp vitality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. In a pilot study, the authors aimed to determine the success rate of dental implants placed in patients who were positive for human immunodeficiency virus (HIV) and were receiving different regimens of highly active anti-retroviral therapy (HAART). They considered patients` levels of cluster of differentiation (CD) 4(+) cells and viral load, and they attempted to verify whether patients with baseline biochemical signs of bone mineral density loss could experience osseointegration impairment. Materials and Methods. One of the authors, a dentist, placed dental implants in the posterior mandibles of 40 volunteers, divided into three groups: one composed of HIV-positive patients receiving protease inhibitor (PI)-based HAART; a second composed of HIV-positive patients receiving nonnucleoside reverse transcriptase inhibitor based HAART (without PI); and a control group composed of HIV-negative participants. The authors assessed pen-implant health six and 12 months after implant loading. They analyzed the success of the implants in relation to CD4(+) cell counts, viral load and baseline pyridinoline and deoxypyridinoline values. Results. The authors followed 59 implants for 12 months after loading. Higher baseline levels of pyridinoline and deoxypyridinoline found in HIV-positive participants did not interfere with osseointegration after 12 months of follow-up. Average pen-implant bone loss after 12 months was 0.49 millimeters in group 1, 0.47 mm in group 2, and 0.55 mm in the control group. Conclusions. The placement of dental implants in HIV-positive patients is a reasonable treatment option, regardless of CD4(+) cell count, viral load levels and type of antiretroviral therapy. Longer, follow-up periods are necessary to ascertain the predictability of the long-term success of dental implants in these patients. Clinical Implications. Limited published scientific evidence is available to guide clinicians in regard to possible increased risks associated with dental implant placement in HIV-positive patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the micro-shear bond strength of 5 adhesive systems to enamel, one single-bottle acid-etch adhesive (O), two self-etching primers (P) and two all-in-one self-etching adhesives (S). Method: Sixty premolar enamel surfaces (buccal or lingual) were ground flat with 400- and 600-grit SiC papers and randomly divided into 5 groups (n=12), according to the adhesive system.. SB2 - Single Bond 2 (O); CSE - Clearfil SE Bond (P); ADS - AdheSE (P); PLP - Adper Prompt L-Pop (S); XE3 - Xeno III (S). Tygon tubing (inner diameter of 0.8mm) restricted the bonding area to obtain the resin composite (Z250) cylinders. After storage in distilled water at 37 degrees C for 24h and thermocycling, micro-shear testing was performed (crosshead speed of 0.5mm/min). Data were submitted to one-way ANOVA and Tukey test (a=5%). Samples were also subjected to stereomicroscopic and SEM evaluations after micro-shear testing. Mean bond strength values (MPa +/- SD) and the results of Tukey test were: SB2: 36.36(+/- 3.34)a; ADS: 33.03(+/- 7.83)a; XE3: 32.76(+/- 5.61)a; CSE: 30.61(+/- 6.68)a; PLP: 22.17(+/- 6.05)b. Groups with the same letter were not statistically different. It can be concluded that no significant difference was there between SB2, ADS, XE3 and CSE, in spite of different etching patterns of these adhesives. Only PLP presented statistically lower bond strengths compared with others. J Clin Pediatr Dent 35(3): 301-304, 2011

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Individuals with cariogenic diet can also consume erosive beverages. Thus, it seems necessary to investigate a possible caries/erosion interaction. To test in situ/ex vivo a combination of these challenges, 11 subjects wore intraoral appliances containing four enamel blocks randomly assigned. In the first 2-week phase, the appliances were immersed in a cola drink 3 times/day. Two blocks were free of plaque (erosion only: EO) and two blocks were covered with plaque (erosion + plaque: EP). In the second 2-week phase, four new blocks were all covered with plaque and subjected to a sucrose solution 8 times/day. Among the four new blocks, two were also subjected to the cola drink 3 times/day (erosion + caries: EC) while the other two were not (caries only: CO). Thus, in EO, the specimens were fixed at the intraoral appliance level. In EP, EC and CO they were fixed 1.0 mm under the appliance level and covered with plastic meshes for dental plaque accumulation. Changes in wear and hardness were measured. Data were tested using ANOVA and Tukey`s test (p < 0.05). Mean values of wear (mu m) and change in hardness (kp/mm(2)) were: EO 4.82/310; EP 0.14/48; EC 0.34/245; CO 0.42/309. With respect to surface softening, EP and EC differed significantly from each other and from EO and CO, which did not differ significantly. EO presented significantly higher wear than the other groups. The data suggest that the presence of dental plaque can decrease the acid attack of an erosive drink and the association of erosive and cariogenic challenges showed less enamel alterations when compared to erosive or cariogenic challenges only. Copyright (C) 2008 S. Karger AG, Basel

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Physical and bioceramic incorporation surface treatments at the nanometer scale showed higher means of bone-to-implant contact (BIC) and torque values compared with surface topography at the micrometer scale; however, the literature concerning the effect of nanometer scale parameters is sparse. Purpose: The aim of this study was to evaluate the influence of two different implant surfaces on the percentage bone-to-implant contact (BIC%) and bone osteocyte density in the human posterior maxilla after 2 months of unloaded healing. Materials and Methods: The implants utilized presented dual acid-etched (DAE) surface and a bioceramic molecular impregnated treatment (Ossean(R), Intra-Lock International, Boca Raton, FL, USA) serving as control and test, respectively. Ten subjects (59 1 9 years of age) received two implants (one of each surface) during conventional implant surgery in the posterior maxilla. After the non-loaded period of 2 months, the implants and the surrounding tissue were removed by means of a trephine and were non-decalcified processed for ground sectioning and analysis of BIC%, bone density in threaded area (BA%), and osteocyte index (Oi). Results: Two DAE implants were found to be clinically unstable at time of retrieval. Histometric evaluation showed significantly higher BIC% and Oi for the test compared to the control surface (p < .05), and that BA% was not significantly different between groups. Wilcoxon matched pairs test was used to compare the differences of histomorphometric variables between implant surfaces. The significance test was conducted at a 5% level of significance. Conclusion: The histological data suggest that the bioceramic molecular impregnated surface-treated implants positively modulated bone healing at early implantation times compared to the DAE surface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Peak expiratory flow (PEF) was measured in healthy children aged five to ten years in order to provide baseline values and to determine correlations between PEF and factors such as gender, age and type of school. Methods: After the Ethical Committee of Research in Human of the School of Medicine of ABC - FMABC approval, PEF and height were measured in 1942 children between five and ten years old from nine public schools and nine private schools throughout Sao Bernardo do Campo City. PEF was measured using the Mini-Wright Peak Flow Meter (Clement Clarke International Ltd.) and. height was measured using a Sanny professional stadiometer. Results: Significant differences were found in values for PEF: higher values were seen in older students in comparison with younger students, in males in comparison with females and in students from private schools in comparison with public schools, with average values ranging from 206 L/min to 248 L/min,. Linear correlations were seen for PEF values with both height and age (Spearman Coefficient). Conclusions: Differences were seen for PEF between genders and between types of school, and a linear correlation was seen for PEF with both age and height in healthy children from five to ten years old.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In vitro studies have provided conflicting evidence of temperature changes in the tooth pulp chamber after low-level laser irradiation of the tooth surface. The present study was an in vitro evaluation of temperature increases in the human tooth pulp chamber after diode laser irradiation (GaAlAs, lambda = 808 nm) using different power densities. Twelve human teeth (three incisors, three canines, three premolars and three molars) were sectioned in the cervical third of the root and enlarged for the introduction of a thermocouple into the pulp chamber. The teeth were irradiated with 417 mW, 207 mW and 78 mW power outputs for 30 s on the vestibular surface approximately 2 mm from the cervical line of the crown. The highest average increase in temperature (5.6A degrees C) was observed in incisors irradiated with 417 mW. None of the teeth (incisors, canines, premolars or molars) irradiated with 207 mW showed temperature increases higher than 5.5A degrees C that could potentially be harmful to pulp tissue. Teeth irradiated with 78 mW showed lower temperature increases. The study showed that diode laser irradiation with a wavelength of 808 nm at 417 mW power output increased the pulp chamber temperature of certain groups of teeth, especially incisors and premolars, to critical threshold values for the dental pulp (5.5A degrees C). Thus, this study serves as a warning to clinicians that ""more"" is not necessarily ""better"".

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid, sensitive and specific method for quantifying ciprofibrate in human plasma using bezafibrate as the internal standard (IS) is described. The sample was acidified prior extraction with formic acid (88%). The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (diethyl ether/dichloromethane 70/30 (v/v)). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS/MS). Chromatography was performed using Genesis C18 4 mu m analytical column (4.6 x 150 mm i.d.) and a mobile phase consisting of acetonitrile/water (70/30, v/v) and 1 mM acetic acid. The method had a chromatographic run time of 3.4 min and a linear calibration curve over the range 0.1-60 mu g/mL (r > 0.99). The limit of quantification was 0.1 mu g/mL. The intra- and interday accuracy and precision values of the assay were less than 13.5%. The stability tests indicated no significant degradation. The recovery of ciprofibrate was 81.2%, 73.3% and 76.2% for the 0.3, 5.0 and 48.0 ng/mL standard concentrations, respectively. For ciprofibrate, the optimized parameters of the declustering potential, collision energy and collision exit potential were -51 V, -16 eV and -5 V, respectively. The method was also validated without the use of the internal standard. This HPLC-MS/MS procedure was used to assess the bioequivalence of two ciprofibrate 100 mg tablet formulations in healthy volunteers of both sexes. The following pharmacokinetic parameters were obtained from the ciprofibrate plasma concentration vs. time curves: AUC(last), AUC(0-168 h), C(max) and T(max). The geometric mean with corresponding 90% confidence interval (CI) for test/reference percent ratios were 93.80% (90% CI = 88.16-99.79%) for C(max), 98.31% (90% CI = 94.91-101.83%) for AUC(last) and 97.67% (90% CI = 94.45-101.01%) for AUC(0-168 h). Since the 90% Cl for AUC(last), AUC(0-168 h) and C(max) ratios were within the 80-125% interval proposed by the US FDA, it was concluded that ciprofibrate (Lipless (R) 100 mg tablet) formulation manufactured by Biolab Sanus Farmaceutica Ltda. is bioequivalent to the Oroxadin (R) (100 mg tablet) formulation for both the rate and the extent of absorption. (C) 2011 Published by Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Data obtained during routine diagnosis of human T-cell lymphotropic virus type 1 (HTLV-1) and 2 (HTLV-2) in ""at-risk"" individuals from Sao Paulo, Brazil using signal-to-cutoff (S/C) values obtained by first, second, and third generation enzyme immunoassay (EIA) kits, were compared. The highest S/C values were obtained with third generation EIA kits, but no correlation was detected between these values and specific antibody reactivity to HTLV-1, HTLV-2, or untyped HTLV (p = 0.302). In addition, use of these third generation kits resulted in HTLV-1/2 false-positive samples. In contrast, first and second generation EIA kits showed high specificity, and the second generation EIA kits showed the highest efficiency, despite lower S/C values. Using first and second generation EIA kits, significant differences in specific antibody detection of HTLV-1, relative to HTLV-2 (p = 0.019 for first generation and p < 0.001 for second generation EIA kits) and relative to untyped HTLV (p = 0.025 for first generation EIA kits), were observed. These results were explained by the composition and format of the assays. In addition, using receiver operating characteristics (ROC) analysis, a slight adjustment in cutoff values for third generation EIA kits improved their specificities and should be used when HTLV ""at-risk"" populations from this geographic area are to be evaluated. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. Periodontal diseases (PDs) are infectious diseases in which periodontopathogens trigger chronic inflammatory and immune responses that lead to tissue destruction. Recently, viruses have been implicated in the pathogenesis of PDs. Individuals infected with human T lymphotropic virus 1 (HTLV-1) present with abnormal oral health and a marked increased prevalence of periodontal disease. Methods. In this study, we investigated the patterns of periodontopathogen infection and local inflammatory immune markers in HTLV-1-seropositive individuals with chronic periodontitis (CP/HTLV-1 group) compared with HTLV-1 -seronegative individuals with chronic periodontitis (CP group) and periodontally healthy, HTLV-1 -seronegative individuals (control group). Results. Patients in the CP/HTLV-1 group had significantly higher values of bleeding on probing, mean probing depth, and attachment loss than patients in the CP group. The expression of tumor necrosis factor a and interleukin (IL) 4 was found to be similar in the CP and CP/HTLV-1 groups, whereas IL-12 and IL-17 levels trended toward a higher expression in the CP/HTLV-1 group. A significant increase was seen in the levels of IL-1 beta and interferon gamma in the CP/HTLV-1 group compared with the CP group, whereas expression of the regulatory T cell marker FOXp3 and IL-10 was significantly decreased in the lesions from the CP/HTLV-1 group. Interestingly, similar frequency and/or load of periodontopathogens (Porphyromonas gingivalis, Tannerella forsythia, Treponema denticola, and Aggregatibacter actinomycetemcomitans) and frequency of viruses (herpes simplex virus 1, human cytomegalovirus, and Epstein-Barr virus) characteristically associated with PDs were found in the CP/HTLV and CP groups. Conclusions. HTLV-1 may play a critical role in the pathogenesis of periodontal disease through the deregulation of the local cytokine network, resulting in an exacerbated response against a standard periodontopathogen infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dehydroepiandrosterone ( DHEA) is known as an intermediate in the synthesis of mammalian steroids and a potent uncompetitive inhibitor of mammalian glucose-6-phosphate dehydrogenase (G6PDH), but not the enzyme from plants and lower eukaryotes. G6PDH catalyzes the first step of the pentose-phosphate pathway supplying cells with ribose 5-phosphate, a precursor of nucleic acid synthesis, and NADPH for biosynthetic processes and protection against oxidative stress. In this paper we demonstrate that also G6PDH of the protozoan parasite Trypanosoma brucei is uncompetitively inhibited by DHEA and epiandrosterone (EA), with K(i) values in the lower micromolar range. A viability assay confirmed the toxic effect of both steroids on cultured T. brucei bloodstream form cells. Additionally, RNAi mediated reduction of the G6PDH level in T. brucei bloodstream forms validated this enzyme as a drug target against Human African Trypanosomiasis. Together these findings show that inhibition of G6PDH by DHEA derivatives may lead to the development of a new class of anti-trypanosomatid compounds. Crown Copyright (C) 2009 Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel approach of using a gold disc microelectrode to analyze sweat samples for copper ions by anodic square wave stripping voltammetry (SW stripping voltammetry) is described Sweat was collected from the lower back of four subjects after physical exercise and the sample volume required for the determinations was 100 mu L. Under the optimized conditions the calibration plot was linear over the range 1-100 mu mol L(-1) Cu(II) with a limit of detection of 0 25 mu mol L(-1) The precision was evaluated by carrying out five replicate measurements in a 1 mu mol L(-1) Cu(II) solution and the standard deviation was found to be 1 5% Measurements were performed by inserting the microelectrode into sweat drops and Cu(II) concentrations in the analyzed samples ranged from 09 to 28 mu mol L(-1) Values obtained by the proposed voltammetric method agreed well with those found using graphite furnace atomic absorption spectroscopy (GFAAS) (C) 2010 Elsevier B V All rights reserved

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CD and EPR were used to characterize interactions of oxindole-Schiff base copper(II) complexes with human serum albumin (HSA). These imine ligands form very stable complexes with copper, and can efficiently compete for this metal ion towards the specific N-terminal binding site of the protein, consisting of the amino acid sequence Asp-Ala-His. Relative stability constants for the corresponding complexes were estimated from CD data, using the protein as competitive ligand, with values of log K(CuL) in the range 15.7-18.1, very close to that of [Cu(HSA)] itself, with log K(CuHSA) 16.2. Some of the complexes are also able to interfere in the a-helix structure of the protein, while others seem not to affect it. EPR spectra corroborate those results, indicating at least two different metal species in solution, depending on the imine ligand. Oxidative damage to the protein after incubation with these copper(II) complexes, particularly in the presence of hydrogen peroxide, was monitored by carbonyl groups formation, and was observed to be more severe when conformational features of the protein were modified. Complementary EPR spin-trapping data indicated significant formation of hydroxyl and carbon centered radicals, consistent with an oxidative mechanism. Theoretical calculations at density functional theory (DFT) level were employed to evaluate Cu(II)-L binding energies, L -> Cu(II) donation, and Cu(II) -> L back-donation, by considering the Schiff bases and the N-terminal site of HSA as ligands. These results complement previous studies on cytotoxicity, nuclease and pro-apoptotic properties of this kind of copper(II) complexes, providing additional information about their possibilities of transport and disposition in blood plasma. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A column switching LC method is presented for the analysis of fluoxetine (FLU) and norfluoxetine (NFLU) by direct injection of human plasma using a lab-made restricted access media (RAM) column. A RAM-BSA-octadecyl silica (C-18) column (40 min x 4.6 mm, 10 mu m) is evaluated in both backflush and foreflush elution modes and coupled with a C-18 lab-made (50 mm x 4.6 mm, 3 pm) analytical column in order to perform online sample preparation. Direct injection of 100 mu L, of plasma samples is possible with the developed approach. In addition, reduction of sample handling is obtained when compared with traditional liquid-liquid extraction (LLE) and SPE. The total analysis time is around 20 min. A LOQ of 15 ng/mL is achieved in a concentration range of 15-500 ng/mL, allowing the therapeutic drug monitoring of clinical samples. The precision values achieved are lower than 15% for all the evaluated points with adequate recovery and accuracy. Furthermore, no matrix interferences are found in the analysis and the proposed method shows to be an adequate alternative for analysis of FLU in plasma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This study evaluated the quality of DNA obtained from stored human saliva and its applicability to human identification. METHODS: The saliva samples of 20 subjects, collected in the form of saliva in natura and from mouth swabs and stored at -20ºC, were analyzed. After 7 days, the DNA was extracted from the 40 saliva samples and subjected to PCR and electrophoresis. After 180 days, the technique was repeated with the 20 swab samples. RESULTS: The first-stage results indicated that DNA was successfully extracted in 97.5% of reactions, 95% of saliva in natura and 100% of swab saliva samples, with no statistically significant difference between the forms of saliva. In the second phase, the result was positive for all 20 analyzed samples (100%). Subsequently, in order to analyze the quality of the DNA obtained from human saliva, the SIX3-2 gene was tested on the 20 mouth swab samples, and the PCR products were digested using the MbO1 restriction enzyme to evaluate polymorphisms in the ADRA-2 gene, with positive results for most samples. CONCLUSION: It was concluded that the quantity and quality of DNA from saliva and the techniques employed are adequate for forensic analysis of DNA.