36 resultados para Glass painting and staining, French.
Resumo:
In this study, the influence of the glass addition and sintering parameters on the densification and mechanical properties of tetragonal zirconia polycrystals (3Y-TZP) ceramics were evaluated. High-purity tetragonal ZrO2 powder and La2O3-rich glass were used as starting powders. Two compositions based on ZrO2 and containing 5wt.% and 10wt.% of La2O3-rich glass were studied in this work. The starting powders were mixed/milled by planetary milling, dried at 90 degrees C for 24 h, sieved through a 60 mesh screen and uniaxially cold pressed under 80 MPa. The samples were sintered in air at 1200 degrees C, 1300 degrees C, 1400 degrees C for 60 min and at 1450 degrees C for 120 min, with heating and cooling rates of 10 degrees C/min. Sintered samples were characterized by relative density, X-ray diffraction (XRD) and scanningelectron microscopy (SEM). Hardness and fracture toughness were obtained by Vickers indentation method. Dense sintered samples were obtained for all conditions. Furthermore, only tetragonal-ZrO2 was identified as crystalline phase in sintered samples, independently of the conditions studied. Samples sintered at 1300 degrees C for 60 min presented the optimal mechanical properties with hardness and fracture toughness values near to 12 GPa and 8.5 MPa m(1/2) respectively. (c) 2007 Elsevier B.V, All rights reserved.
Resumo:
Phosphoniobate glasses with composition (mol%) (100-x) NaPO(3)-xNb(2)O(5) ( x varying from 11 to 33) were prepared and characterized by means of thermal analysis, Fourier transform infrared spectroscopy, Raman scattering and (31)P nuclear magnetic resonance. The addition of Nb(2)O(5) to the polyphosphate base glass leads to depolymerization of the metaphosphate structure. Different colors were observed and assigned as indicating the presence of Nb(4+) ions, as confirmed by electron paramagnetic resonance measurements. The color was observed to depend on the glass composition and melting temperature as well. Er(3+) containing samples were also prepared. Strong emission in the 1550 nm region was observed. The Er(3+4)I(15/2) emission quantum efficiency was observed to be 90% and the quenching concentration was observed to be 1.1 mol%( 1.45 x 10(20) ions cm(-3)). Planar waveguides were prepared by Na(+)-K(+)-Ag(+) ion exchange with Er(3+) containing samples. Optical parameters of the waveguides were measured at 632.8, 543.5 and 1550 nm by the prism coupling technique as a function of the ion exchange time and Ag(+) concentration. The optimized planar waveguides show a diffusion depth of 5.9 mu m and one propagating mode at 1550 nm.
Resumo:
Purpose: Subclinical inflammation may be observed in patients, using topical antiglaucomatous drugs. The objective,e of this study was to investigate inflammation in conjunctiva of glaucoma patients using prostaglandin analogs, by the detection of a immunogenetic marker (HLA-DR) and compare the effect of 3 different drugs: latanoprost, bimatoprost, and travoprost in the induction of this inflammation. Subjects and Methods: Thirty-three patients with primary open-angle glaucoma were evaluated without and with prostaglandin analogs topical therapy. Imprints of conjunctival cells were obtained, fixed on glass slides. and Prepared for immunohistochemical analysis. Results: Before the use of prostaglandin analogs, 4 of the 33 patients evaluated presented expression (of HLA-DR in the conjunctiva (mild). After 1 month oil prostaglandin analog treatment, all but 1 patient presented HLA-DR staining. HLA-DR expression of these 32 patients was scored as mild (19 patients), medium (11 patients), or intense (2 patients). The differences were statistically significant both when the presence and the increased expression of HLA-DR were considered (P<0.001). When the 3 different groups were analyzed (latanoprost, bimatoprost, and travoprost) no statistically significant difference was round (P 0.27). Conclusions: The use of prostaglandin analogs eye drops provokes, a reaction, observed by HLA-DR subclinical inflammatory expression, even after a short period of treatment, independently of the class of the prostaglandin analogs used.
Resumo:
Comparative studies between 5 French guiding catheter and others of larger size using the transfemoral approach to coronary stenting have not been described. Coronary stent implantation was performed in 90 patients in a randomized trial. The primary end-point was to compare the incidence of successful uncomplicated stent implantation per lesion with the 5F and 7F guiding catheters. Patients were excluded for excessive vessel tortuosity or anticipated need for equipment not fitting through a 5 catheter. Baseline characteristics and the use of direct stenting did not differ between the two groups. The primary success rate was 97.8% per patient in both groups and 98% per lesion in the 5 French and 97.9% in the 7 French. Guiding catheter change was necessary in 1 patient in each group to successfully complete the procedure in both groups. The amount of contrast used was 63 +/- 27.3 mL in the 5 French and 76 +/- 25 mL in the 7 French groups (P < 0.05). Vascular complications and blood transfusions occurred somewhat more frequently in the 7 French group (P = 0.058). The manual compression time after sheath removal was 5.1 +/- 2.0 min and 8.0 +/- 4.3 min, respectively, in the 5 and 7 French groups (P < 0.01). In conclusion, the 5 French guiding catheters showed a similar success rate with coronary stenting when compared to the 7 French, but the amount of contrast used and manual compression time after sheath removal, as well as the rate of vascular and bleeding complications, were reduced in the 5 French group.
Resumo:
Objective-To assess viability of innervation in bowel segments appearing macroscopically viable from dogs with intussusception. Animals-7 dogs without gastrointestinal dysfunction that had been euthanized for reasons unrelated to the study (control dogs) and 13 dogs with intussusception that underwent enterectomy and intestinal anastomosis (affected dogs). Procedures-A total of 31 samples of intestinal tissue were obtained from the control dogs; 28 samples were obtained from affected dogs during surgery. Samples were histologically and immunohistochemically prepared and subjectively scored for degree of vacuolization and staining, respectively. Other data collected included mean muscle cell density of circular and longitudinal muscular layers, ratio between areas of muscular layers, mean number of myenteric plexuses, mean ganglion cell density of myenteric plexuses, and degree of degeneration in neuronal plexuses as estimated through synaptophysin and neuron-specific enolase (NSE) immunoreactivity. Results-Mean muscle cell density of longitudinal muscular layers, ratio between areas of muscular layers, and synaptophysin immunoreactivity did not differ significantly between affected and control dogs; values of all other variables did. Correlations were evident between mean ganglion cell density in myenteric plexuses and mean muscle cell density in circular muscular layers, degree of neuronal degeneration in myenteric plexuses and NSE immunoreactivity, and degree of neuronal degeneration in myenteric plexuses and mean ganglion cell density of myenteric plexuses. Conclusions and Clinical Relevance-Innervation may be impaired in bowel segments that appear macroscopically viable. Therefore, careful evaluation of preserved surgical margins during enterectomy and enteroanastomosis and monitoring of digestive function after surgery are important. (Am J Vet Res 2010;71:636-642)
Resumo:
Objective. To investigate the processing induced particle alignment on fracture behavior of four multiphase dental ceramics (one porcelain, two glass-ceramics and a glass-infiltrated-alumina composite). Methods. Disks (empty set12mm x 1.1 mm-thick) and bars (3 mm x 4 mm x 20 mm) of each material were processed according to manufacturer instructions, machined and polished. Fracture toughness (K(IC)) was determined by the indentation strength method using 3-point bending and biaxial flexure fixtures for the fracture of bars and disks, respectively. Microstructural and fractographic analyses were performed with scanning electron microscopy, energy dispersive spectroscopy and X-ray diffraction. Results. The isotropic microstructure of the porcelain and the leucite-based glass-ceramic resulted in similar fracture toughness values regardless of the specimen geometry. On the other hand, materials containing second-phase particles with high aspect ratio (lithium disilicate glass-ceramic and glass-infiltrated-alumina composite) showed lower fracture toughness for disk specimens compared to bars. For the lithium disilicate glass-ceramic disks, it was demonstrated that the occurrence of particle alignment during the heat-pressing procedure resulted in an unfavorable pattern that created weak microstructural paths during the biaxial test. For the glass-infiltrated-alumina composite, the microstructural analysis showed that the large alumina platelets tended to align their large surfaces perpendicularly to the direction of particle deposition during slip casting of green preforms. Significance. The fracture toughness of dental ceramics with anisotropic microstructure should be determined by means of biaxial testing, since it results in lower values. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
This study aimed at investigating in vitro osteogenesis on three fluorcanasite glass-ceramic compositions with different solubilities (K3, K5, and K8). Osteoblastic cells were obtained from human alveolar bone fragments and cultured under standard osteogenic condition until subconfluence. First passage cells were cultured on K3, K5, and K8 and on Bioglass (R) 45S5 (45S5-control). Cell adhesion was evaluated at 24 h. For proliferation and viability, cells were cultured for 1, 4, and 10 days. Total protein content and alkaline phosphatase (ALP) activity were measured at 7, 14, and 21 days. Cultures were stained with Alizarin red at 21 days, for detection of mineralized matrix. Data were compared by ANOVA followed by Duncan`s test. Cell adhesion, cell proliferation, viability, total protein content, and ALP activity were not affected by fluorcanasite glass-ceramic composition and solubility. Bone-like formation was similar on all fluorcanasite-glass ceramics and was reduced compared to 45S5. The changes in the chemical composition and consequently solubility of the fluorcanasite glass-ceramics tested here did not significantly alter the in vitro osteogenesis. Further modifications of the chemical composition of the fluorcanasite glass-ceramic would be required to improve bone response, making this biomaterial a good candidate to be employed as a bone substitute.
Resumo:
Microwave techniques were applied to the study of dielectric properties of phosphate glasses on the basis of contributions from permanent and induced dipolar polarization of local structural units interacting with the electrical component of the electromagnetic radiation. The dielectric constant of the selected glass system (100-x)(50P(2)O(5)center dot 25Li(2)O center dot 25Na(2)O)center dot xFe(2)O(3), where 0 <= x <= 21 is in mol%, was measured using a microwave setup assembled to measure the phase shift of the standing wave pattern produced by the insertion of the sample. It is shown that the Fe2+ ions contribute effectively to the dielectric constant, as expected from the interactions of the dipoles of the local charge compensation pairs with the microwave radiation. However, there is the possibility of occurrence of some ions Fe3+, in general, at low iron content, which reinforces the glass structure and, therefore, decreases the dielectric constant. There is a gradual conversion from Fe3+ to Fe2+ as the iron ions increases. This is possibly the reason of the anomaly in the dielectric constant values observed in the results. These assumptions can be checked by results of electronic paramagnetic resonance (EPR) and optical absorption (OA). The dielectric constant of the glasses studied in this work was found to increase with the temperature in the range of 25-330 degrees C. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Supernumerary marker chromosomes (sSMC) may or may not be associated with an abnormal phenotype, depending on the presence of euchromatin, on their chromosomal origin and whether they are inherited. Over 80% of sSMCs are derived from acrocentric chromosomes and half of them include the short arm of chromosome 15. Generally, they appear as bisatellited isodicentric marker chromosomes, most of them are symmetric. These chromosomes are normally originated de novo and are associated with mild to severe intellectual disability but not with physical abnormalities. We report on a patient with an SMC studied using classical and molecular cytogenetic procedures (G and C banding, NOR staining, painting and centromeric fluorescent in situ hybridization (FISH), BAC-FISH, and SKY). The MLPA technique and DNA polymorphic markers were used in order to identify its parental origin. The marker chromosome, monosatellited and monocentric, was found to be derived from a maternal chromosome 15 and was defined as 15pter-q21.2. This is the report of the largest de novo monosatellited 15q marker chromosome ever published presenting detailed cytogenetic and clinical data. It was associated with a phenotype including cardiac defect, absence of septum pellucidum, and dysplasia of the corpus callosum. (C) 2010 Wiley-Liss, Inc.
Resumo:
We study the thermodynamic properties and the phase diagrams of a multi-spin antiferromagnetic spherical spin-glass model using the replica method. It is a two-sublattice version of the ferromagnetic spherical p-spin glass model. We consider both the replica-symmetric and the one-step replica-symmetry-breaking solutions, the latter being the most general solution for this model. We find paramagnetic, spin-glass, antiferromagnetic and mixed or glassy antiferromagnetic phases. The phase transitions are always of second order in the thermodynamic sense, but the spin-glass order parameter may undergo a discontinuous change.
Resumo:
This work presents the optical properties of erbium-doped and erbium/ytterbium codoped Na(2)O-Al(2)O(3)-TiO(2)-Nb(2)O(5)-P(2)O(5) glass systems and also the characterization of planar waveguides obtained by typical thermally assisted Ag+<-> Na+ ion-exchange process. The glass systems allow the preparation of single mode and multimode planar waveguides presenting a strong and relatively broad emission at 1536 nm. The emission signal in the infrared region is intensified for silver-containing samples when compared with free-silver samples. The emission signal intensification may be attributed to a nonplasmonic energy transfer from silver species to Er3+ ions as no bands related to surface plasmon resonance (SPR) of silver nanoparticles were observed.
Resumo:
The aim of this study was to investigate the histological and histomorphometrical bone response to three Biosilicates with different crystal phases comparing them to Bioglass®45S5 implants used as control. Ceramic glass Biosilicate and Bioglass®45S5 implants were bilaterally inserted in rabbit femurs and harvested after 8 and 12 weeks. Histological examination did not revealed persistent inflammation or foreign body reaction at implantation sites. Bone and a layer of soft tissue were observed in close contact with the implant surfaces in the medullary canal. The connective tissue presented few elongated cells and collagen fibers located parallel to implant surface. Cortical portion after 8 weeks was the only area that demonstrated significant difference between all tested materials, with Biosilicate 1F and Biosilicate 2F presenting higher bone formation than Bioglass®45S5 and Biosilicate® vitreo (p=0.02). All other areas and periods were statistically non-significant (p>0.05). In conclusion, all tested materials were considered biocompatible, demonstrating surface bone formation and a satisfactory behavior at biological environment.
Resumo:
Prosthetic restorations that have been tried in the patient's mouth are potential sources of infection. In order to avoid cross-infection, protocols for infection control should be established in dental office and laboratory. This study evaluated the antimicrobial efficacy of disinfectants on full metal crowns contaminated with microorganisms. Full crowns cast in a Ni-Cr alloy were assigned to one control group (n=6) and 5 experimental groups (n=18). The crowns were placed in flat-bottom glass balloons and were autoclaved. A microbial suspension of each type of strain - S. aureus, P. aeruginosa, S. mutans, E. faecalis and C. albicans- was aseptically added to each experimental group, the crowns being allowed for contamination during 30 min. The contaminated specimens were placed into recipients with the chemical disinfectants (1% and 2% sodium hypochlorite and 2% glutaraldehyde) for 5, 10 and 15 min. Thereafter, the crowns were placed into tubes containing different broths and incubated at 35ºC. The control specimens were contaminated, immersed in distilled water for 20 min and cultured in Thioglycollate broth at 35ºC. Microbial growth assay was performed by qualitative visual examination after 48 h, 7 and 12 days. Microbial growth was noticed only in the control group. In the experimental groups, turbidity of the broths was not observed, regardless of the strains and immersion intervals, thus indicating absence of microbial growth. In conclusion, all chemical disinfectants were effective in preventing microbial growth onto full metal crowns.
Resumo:
Edible films are thin materials based on biopolymers and food additives. The aim of this work is a review on the application of dynamic mechanical analysis in edible film technology. After a brief review of the linear visco-elasticity theory, a description of some practical aspects related to dynamic mechanical analysis, such as sample fixation and sample dehydration during analysis and types and modes of tests are presented. Thus, the use of temperature scanning analysis for glass transition and for plasticizer-biopolymer compatibility studies and frequency scanning tests, less common in edible film technology, are critically reviewed.
Resumo:
Neste trabalho são descritas as técnicas de análise estatística utilizadas e a acessibilidade estatística em uma amostra dos artigos originais publicados no período 1996-2006 em duas revistas de pesquisa na área de fruticultura: a Revista Brasileira de Fruticultura (RBF) e a revista francesa Fruits. No total foram classificados 986 artigos em 16 categorias de análise estatística, ordenadas em grau ascendente de complexidade. No período analisado, foi constatado um aumento no uso de análises mais sofisticadas ao longo do tempo em ambos as revistas. Os trabalhos publicados pela RBF aplicaram com maior freqüência técnicas estatísticas mais complexas, com maior utilização de delineamentos em blocos aleatorizados, arranjos fatoriais, parcelas subdivididas e modelos hierárquicos, e do teste de Tukey para comparações múltiplas de médias. Nos trabalhos publicados pela revista Fruits, predominou o uso de outros testes paramétricos e do teste de Duncan. O pacote estatístico SAS foi o mais utilizado nos artigos publicados em ambas as revistas. Os leitores da revista RBF precisaram de um nível de conhecimento estatístico mais elevado para ter acesso à maior parte dos artigos publicados no período, em comparação com os leitores da revista francesa.