24 resultados para Fouillou, Jacques.
Resumo:
Ectatomma parasiticum Feitosa & Fresneau, a new ant species socially parasitic on Ectatomma tuberculatum (Olivier), is described from gynes discovered in Apazapan, state of Veracruz, Mexico, and reared in the laboratory. Ectatomma parasiticum is the first social parasite described in the Ectatomminae. This species can be distinguished from its host by morphological and behavioral features characteristic of the inquilines known in other ant subfamilies including reduced size, thickened petiole, and agonistic interactions with host species.
Resumo:
Introduction. Over the past 20 years our knowledge of premature ejaculation (PE) has significantly advanced. Specifically, we have witnessed substantial progress in understanding the physiology of ejaculation, clarifying the real prevalence of PE in population-based studies, reconceptualizing the definition and diagnostic criterion of the disorder, assessing the psychosocial impact on patients and partners, designing validated diagnostic and outcome measures, proposing new pharmacologic strategies and examining the efficacy, safety and satisfaction of these new and established therapies. Given the abundance of high level research it seemed like an opportune time for the International Society for Sexual Medicine (ISSM) to promulgate an evidenced-based, comprehensive and practical set of clinical guidelines for the diagnosis and treatment of PE. Aim. Develop clearly worded, practical, evidenced-based recommendations for the diagnosis and treatment of PE for family practice clinicians as well as sexual medicine experts. Method. Review of the literature. Results. This article contains the report of the ISSM PE Guidelines Committee. It affirms the ISSM definition of PE and suggests that the prevalence is considerably lower than previously thought. Evidence-based data regarding biological and psychological etiology of PE are presented, as is population-based statistics on normal ejaculatory latency. Brief assessment procedures are delineated and validated diagnostic and treatment questionnaires are reviewed. Finally, the best practices treatment recommendations are presented to guide clinicians, both familiar and unfamiliar with PE, in facilitating treatment of their patients. Conclusion. Development of guidelines is an evolutionary process that continually reviews data and incorporates the best new research. We expect that ongoing research will lead to a more complete understanding of the pathophysiology as well as new efficacious and safe treatments for this sexual dysfunction. Therefore, it is strongly recommended that these guidelines be re-evaluated and updated by the ISSM every 4 years. Althof SE, Abdo CHN, Dean J, Hackett G, McCabe M, McMahon CG, Rosen RC, Sadovsky R, Waldinger M, Becher E, Broderick GA, Buvat J, Goldstein I, El-Meliegy AI, Giuliano F, Hellstrom WJG, Incrocci L, Jannini EA, Park K, Parish S, Porst H, Rowland D, Segraves R, Sharlip I, Simonelli C, and Tan HM. International Society for Sexual Medicine`s guidelines for the diagnosis and treatment of premature ejaculation. J Sex Med 2010;7:2947-2969.
Resumo:
A girl with vertically acquired HIV infection presented with a 6-month history of dyspnea and chest pain. Computed tomography of the thorax showed a heterogenous mass measuring 13 x 9 x 17 cm located in the anterior mediastinum. Complete surgical resection was accomplished with no complications. The final diagnosis was multilocular thymic cyst, a distinct pathologic entity that is morphologically distinguishable and unrelated to congenital thymic cyst. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Spinal involvement is a common presentation of multiple myeloma (MM); however, the cervical spine is the least common site of myelomatous involvement. Few studies evaluate the results of percutaneous vertebroplasty (PV) in the treatment of MM of the spine. The purpose of this series is to report on the use of PV in the treatment of MM of the cervical spine and to review the literature. From January 1994 to October 2007, four patients (three men and one woman; mean age, 45 years) who underwent five PV for painful MM in the cervical spine were retrospectively reviewed. The pain was estimated by the patient on a verbal analogic scale. Clinical follow-up was available for all patients (mean, 27.5 months; range, 1-96 months). The mean volume of cement injected per vertebral body was 2.3 +/- 0.8 mL (range, 1.0-4.0 mL) with a mean vertebral filling of 55.0 +/- 12.0% (range, 40.0-75.0%). Analgesic efficacy was achieved in all patients. One patient had a spinal instability due to a progression of spinal deformity noted on follow-up radiographs, without clinical symptoms. Cement leakage was detected in three (60%) of the five treated vertebrae. There was no clinical complication. The present series suggests that PV for MM of the cervical spine is safe and effective for pain control; nonetheless, the detrimental impact of the disease on bone quality should prompt close radiological follow-up after PV owing to the risk of spinal instability.
Resumo:
An asymptomatic 48-year-old woman presented to our hospital with a tumor of the rib incidentally diagnosed on a chest roentgenogram. The patient was investigated and underwent tumor resection of the chest wall. The pathologic study revealed that it was cavernous hemangioma. This tumor of the bone is a distinctly uncommon benign vascular tumor, generally occurring in the spine or skull. Hemangiomas involving the rib are even more rare, with only 22 cases described in the literature. However, we suggest that this tumor of the rib should be considered in the differential diagnosis, principally in asymptomatic patients. (Ann Thorac Surg 2011;91:595-6) (C) 2011 by The Society of Thoracic Surgeons
Resumo:
Obesity is a risk factor for GERD and a potential modulator of esophageal motility. To assess whether obese patients differ from non-obese patients in terms of esophageal motility and reflux. Patients (n = 332) were categorized in GERD and controls after clinical assessment, esophageal manometry, and pH monitoring. Non-obese (BMI 16-29.9) and obese (BMI 30-68) were compared in regard of distal esophageal amplitude (DEA), LES pressure (LESP), manometric diagnosis, and esophageal acid exposure (EAE). Obese showed higher DEA in both controls (122 +/- A 53 vs. 97 +/- A 36 mmHg, p = 0.041) and GERD patients (109 +/- A 38 vs. 94 +/- A 46 mmHg, p < 0.001), higher LESP in GERD patients (20.5 +/- A 10.6 vs. 18.2 +/- A 10.6 mmHg, p = 0.049), higher frequency of nutcracker esophagus in controls (30 vs. 0%, p = 0.001), lower frequency of ineffective motility in GERD patients (6 vs. 20%, p = 0.001), and higher EAE in both controls [total EAE: 1.6% (0.7-5.1) vs. 0.9% (0.2-2.4), p = 0.027] and GERD patients [upright EAE: 6.5% (3.8-11.1) vs. 5.2% (1.5-10.6), p = 0.048]. Multiple linear regression showed that BMI was associated either with EAE (p < 0.001), DEA (p = 0.006), or LESP (in men, p = 0.007). Obese patients differed from non-obese in terms of esophageal motility and reflux, regardless of the presence of GERD. Obese patients showed stronger peristalsis and increased acid exposure in the esophagus.
Resumo:
The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length. Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation. A vertical static load of 100 N was applied to the cantilever arm at the distances of 10, 15, and 20 mm from the center of the distal abutment and the absolute values of specific deformation were recorded. Different patterns of abutment deformation were observed according to the framework alloy. The Co-Cr alloy framework resulted in higher levels of abutment deformation than the silver-palladium alloy framework. Abutment deformation was higher with longer cantilever extensions. Physical properties of the alloys used for framework interfere with abutment deformations patterns. Excessively long cantilever extensions must be avoided. To cite this article:Jacques LB, Moura MS, Suedam V, Souza EAC, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses.Clin. Oral Impl. Res. 20, 2009; 737-741.doi: 10.1111/j.1600-0501.2009.01712.x.
Resumo:
In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.
Resumo:
Objectives. The purpose of this study was to investigate the effect of light-curing protocol on degree of conversion (DC), volume contraction (C), elastic modulus (E), and glass transition temperature (T(g)) as measured on a model polymer. It was a further aim to correlate the measured values with each other. Methods. Different light-curing protocols were used in order to investigate the influence of energy density (ED), power density (PD), and mode of cure on the properties. The modes of cure were continuous, pulse-delay, and stepped irradiation. DC was measured by Raman micro-spectroscopy. C was determined by pycnometry and a density column. E was measured by a dynamic mechanical analyzer (DMA), and T(g) was measured by differential scanning calorimetry (DSC). Data were submitted to two-and three-way ANOVA, and linear regression analyses. Results. ED, PD, and mode of cure influenced DC, C, E, and T(g) of the polymer. A significant positive correlation was found between ED and DC (r = 0.58), ED and E (r = 0.51), and ED and T(g) (r = 0.44). Taken together, ED and PD were significantly related to DC and E. The regression coefficient was positive for ED and negative for PD. Significant positive correlations were detected between DC and C (r = 0.54), DC and E (r = 0.61), and DC and T(g) (r = 0.53). Comparisons between continuous and pulse-delay modes of cure showed significant influence of mode of cure: pulse-delay curing resulted in decreased DC, decreased C, and decreased T(g). Influence of mode of cure, when comparing continuous and step modes of cure, was more ambiguous. A complex relationship exists between curing protocol, microstructure of the resin and the investigated properties. The overall performance of a composite is thus indirectly affected by the curing protocol adopted, and the desired reduction of C may be in fact a consequence of the decrease in DC. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.