28 resultados para Confiabilidade (Mecânica)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to translate the Structured Clinical Interview for Mood Spectrum into Brazilian Portuguese, measuring its reliability, validity, and defining scores for bipolar disorders. METHOD: Questionnaire was translated (into Brazilian Portuguese) and back-translated into English. Sample consisted of 47 subjects with bipolar disorder, 47 with major depressive disorder, 18 with schizophrenia and 22 controls. Inter-rater reliability was tested in 20 subjects with bipolar disorder and MDD. Internal consistency was measured using the Kuder Richardson formula. Forward stepwise discriminant analysis was performed. Scores were compared between groups; manic (M), depressive (D) and total (T) threshold scores were calculated through receiver operating characteristic (ROC) curves. RESULTS: Kuder Richardson coefficients were between 0.86 and 0.94. Intraclass correlation coefficient was 0.96 (CI 95 % 0.93-0.97). Subjects with bipolar disorder had higher M and T, and similar D scores, when compared to major depressive disorder (ANOVA, p < 0.001). The sub-domains that best discriminated unipolar and bipolar subjects were manic energy and manic mood. M had the best area under the curve (0.909), and values of M equal to or greater than 30 yielded 91.5% sensitivity and 74.5% specificity. CONCLUSION: Structured Clinical Interview for Mood Spectrum has good reliability and validity. Cut-off of 30 best differentiates subjects with bipolar disorder vs. unipolar depression. A cutoff score of 30 or higher in the mania sub-domain is appropriate to help make a distinction between subjects with bipolar disorder and those with unipolar depression.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare the effectiveness of mechanical ventilation of supine versus prone position in hydrochloric acid (HCl)-induced lung dysfunction. METHODS: Twenty, adult, male, Wistar-EPM-1 rats were anesthetized and randomly grouped (n=5 animals per group) as follows: CS-MV (mechanical ventilation in supine position); CP-MV (mechanical ventilation in prone position); bilateral instillation of HCl and mechanical ventilation in supine position (HCl+S); and bilateral instillation of HCl and mechanical ventilation in prone position (HCl+P). All groups were ventilated for 180 minutes. The blood partial pressures of oxygen and carbon dioxide were measured in the time points 0 (zero; 10 minutes before lung injury for stabilization), and at the end of times acid injury, 60, 120 and 180 minutes of mechanical ventilation. At the end of experiment the animals were euthanized, and bronchoalveolar lavages (BALs) were taken to determine the contents of total proteins, inflammatory mediators, and lungs wet-to-dry ratios. RESULTS: In the HCl+P group the partial pressure of oxygen increased when compared with HCl+S (128.0±2.9 mmHg and 111.0±6.7 mmHg, respectively) within 60 minutes. TNF-α levels in BAL do not differ significantly in the HCl+P group (516.0±5.9 pg/mL), and the HCl+S (513.0±10.6 pg/mL). CONCLUSION: The use of prone position improved oxygenation, but did not reduce TNF-α in BAL upon lung dysfunction induced by HCl.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wing diagnostic characters for Culex quinquefasciatus and Culex nigripalpus (Diptera, Culicidae). Culex quinquefasciatus and Culex nigripalpus are mosquitoes of public health interest, which can occur sympatrically in urban and semi-urban localities. Morphological identification of these species may be difficult when specimens are not perfectly preserved. In order to suggest an alternative taxonomical diagnosis, wings of these species were comparatively characterized using geometric morphometrics. Both species could be distinguished by wing shape with accuracy rates ranging from 85-100%. Present results indicate that one can identify these species relying only on wing characters when traditional taxonomical characters are not visible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Em 1848 Pasteur conjeturou que a rotação do plano de polarização da luz em um meio diluído é gerada pelas propriedades de simetria das moléculas do meio no qual a luz se propaga. O objetivo do nosso artigo é de mostrar que Pasteur estava correto usando conhecimentos de eletromagnetismo e mecânica quântica de um curso de graduação em física. Faremos um breve retrospecto das ideias básicas da teoria eletromagnética necessárias para o estudo da atividade óptica. A seguir, usando a teoria de perturbações em mecânica quântica e levando em conta as simetrias das moléculas calcularemos a atividade óptica do meio. Mostraremos que as previsões teóricas, que estão plenamente de acordo com os resultados experimentais, comprovam a hipótese de Pasteur.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The n→π* absorption transition of formaldehyde in water is analyzed using combined and sequential classical Monte Carlo (MC) simulations and quantum mechanics (QM) calculations. MC simulations generate the liquid solute-solvent structures for subsequent QM calculations. Using time-dependent density functional theory in a localized set of gaussian basis functions (TD-DFT/6-311++G(d,p)) calculations are made on statistically relevant configurations to obtain the average solvatochromic shift. All results presented here use the electrostatic embedding of the solvent. The statistically converged average result obtained of 2300 cm-1 is compared to previous theoretical results available. Analysis is made of the effective dipole moment of the hydrogen-bonded shell and how it could be held responsible for the polarization of the solvent molecules in the outer solvation shells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glioxal pode ser obtido a partir de biomassa (como da oxidação de lipídeos) e não é tóxico ou volátil, tendo sido por isso utilizado no presente trabalho como substituto de formaldeído na preparação de resina fenólica do tipo novolaca, sendo usado como catalisador o ácido oxálico, que também pode ser obtido de fontes renováveis. A resina glioxal-fenol foi utilizada na preparação de compósitos reforçados com celulose microcristalina (CM, 30, 50 e 70% em massa), uma celulose com elevada área superficial. As imagens de microscopia eletrônica de varredura (MEV) das superfícies fraturadas demonstraram que os compósitos apresentaram boa interface reforço/matriz, consequência da elevada área superficial da CM e presença de grupos polares (hidroxilas) tanto na matriz como na celulose, o que permitiu a formação de ligações hidrogênio, favorecendo a compatibilidade entre ambas. A análise térmica dinâmico-mecânica (DMTA) demonstrou que todos os compósitos apresentaram elevado módulo de armazenamento à temperatura ambiente. Além disso, o compósito reforçado com 30% de CM apresentou baixa absorção de água, comparável à do termorrígido fenólico, que é utilizado em escala industrial. Os resultados demonstraram que compósitos com boas propriedades podem ser preparados usando elevada proporção de materiais obtidos de biomassa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to translate, validate and verify the reliability of the Body Area Scale (BAS). Participants were 386 teenagers, enrolled in a private school. Translation into Portuguese was conducted. The instrument was evaluated for internal consistency and construct validation analysis. Reproducibility was evaluated using the Wilcoxon test and the coefficient of interclass correlation. The BAS demonstrated good values for internal consistency (0.90 and 0.88) and was able to discriminate boys and girls according to nutritional state (p = 0.020 and p = 0.026, respectively). BAS scores correlated with adolescents' BMI (r = 0.14, p = 0.055; r = 0.23, p = 0.001) and WC (r =0.13, p = 0.083; r = 0.22, 0.002). Reliability was confirmed by the coefficient of inter-class correlation (0.35, p < 0.001; 0.60, p < 0.001) for boys and girls, respectively. The instrument performed well in terms of understanding and time of completion. BAS was successfully translated into Portuguese and presented good validity when applied to adolescents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo da revisão foi analisar aspectos conceituais e operacionais de sistemas de vigilância de eventos adversos pós-vacina. Foram incluídos artigos disponíveis em formato eletrônico, publicados entre 1985 e 2009, selecionados nas bases Medline/PubMed, com as palavras-chave: "adverse events following vaccine", "adverse events following vaccine surveillance", "post-marketing surveillance" e "safety vaccine" e "Phase IV clinical trials", e excluídos aqueles com foco em tipos específicos desses eventos. Foram apontados os principais aspectos que justificam a importância dos eventos adversos pós-vacina em saúde pública, os instrumentos que garantem a segurança das vacinas e as finalidades, atributos, tipos, interpretações de dados, limitações e novos desafios da vigilância de eventos adversos pós-vacina, bem como estratégias para aumentar sua sensibilidade. A revisão é concluída com desafios para os próximos anos, visando à segurança e confiabilidade dos programas de vacinação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: to produce evidence of the validity and reliability of the Body Shape Questionnaire (BSQ) - a tool for measuring an individual's attitude towards his or her body image. METHODS: the study covered 386 young people of both sexes aged between 10 and 18 from a private school and used self-applied questionnaires and anthropometric evaluation. It evaluated the internal consistency, the discriminant validity for differences from the means, according to nutritional status (underweight, eutrophic, overweight and obese), the concurrent validity by way of Spearman's correlation coefficient between the scale and the Body Mass Index (BMI), the waist-hip circumference ratio (WHR) and the waist circumference (WC). Reliability was tested using Wilcoxon's Test, the intraclass correlation coefficient and the Bland-Altman figures. RESULTS: the BSQ displayed good internal consistency (±=0.96) and was capable of discriminating among the total population, boys and girls, according to nutritional status (p<0.001). It correlated with the BMI (r=0.41; p<0.001), WHR (r=-0.10; p=0.043) and WC (r=0.24; p<0.001) and its reliability was confirmed by intraclass correlation (r=0.91; p<0.001) for the total population. The questionnaire was easy to understand and could be completed quickly. CONCLUSIONS: the BSQ presented good results, thereby providing evidence of its validity and reliability. It is therefore recommended for evaluation of body image attitudes among adolescents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a validade do peso, estatura e Índice de Massa Corporal (IMC) referidos e sua confiabilidade para o diagnóstico do estado nutricional de adolescentes de Piracicaba. MÉTODOS: Participaram do estudo 360 adolescentes de ambos os sexos, de escolas públicas de Piracicaba, com idade entre 10 e 15 anos. Os adolescentes auto-relataram seu peso e estatura, sendo esses valores obtidos por medidas diretas, logo em seguida, pelos entrevistadores. A validade do IMC referido foi calculada segundo índices de sensibilidade, especificidade e valor preditivo positivo (VPP). Avaliou-se a concordância entre as categorias de IMC obtido por meio das medidas referidas e aferidas a partir do coeficiente kappa ponderado, coeficiente de correlação de Lin. e gráficos de Bland e Altman e Lin. RESULTADOS: Verificou-se que tanto os meninos quanto as meninas subestimaram o peso (-1,0 meninas e meninos) e a estatura (meninas -1,2 e meninos -0,8) (p < 0,001). Os valores de IMC aferidos e referidos apresentaram uma concordância moderada. A sensibilidade do IMC referido para classificar os indivíduos obesos foi maior para os meninos (87,5%), enquanto a especificidade foi maior para as meninas (92,7%). O VPP foi elevado somente para a classificação da eutrofia. CONCLUSÕES: As medidas referidas de peso e estatura de adolescentes não representam medidas válidas e, portanto, não devem ser usadas em substituição aos valores mensurados. Além disso, verificou-se que 10% dos meninos obesos e 40% das meninas obesas poderiam permanecer não identificados utilizando-se as medidas auto-referidas, confirmando a baixa validade das medidas auto-referidas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mazama gouazoubira, o veado-catingueiro, é uma espécie de cervídeo de porte pequeno, que pode ser encontrado na América do Sul, desde o sul do Uruguai até o norte de Mato Grosso, no Brasil. Este estudo teve como objetivo descrever as membranas fetais e a placenta de M. gouazoubira no terço inicial de gestação. As amostras coletadas foram analisadas macroscopicamente e microscopicamente. O exame do útero demonstrou uma gestação univitelina e um embrião com crown-rump de 13mm. Na análise do embrião pode ser observado o olho pigmentado, as saliências auriculares, o mesonefro e e metanefro em desenvolvimento, o fígado e sua proeminência externa, o estômago, os membros torácicos e os brotos dos membros pélvicos. A placenta apresentou-se oligocotiledonária e no útero puderam ser observadas nove carúnculas. O saco gestacional mediu 15cm de comprimento e, como observado no início da gestação dos ruminantes domésticos, os cotilédones não puderam ser identificados macroscopicamente. Uma fraca adesão foi observada entre as carúnculas e a membrana corioalantóica (cotilédones) que formavam os placentônios. A membrana corioalantóica demonstrou um alantóide bem vascularizado composto por uma fina camada de células de núcleos e citoplasmas alongados. Na outra face da membrana, o cório foi composto por células cúbicas, de citoplasmas escassos e núcleos grandes e arredondados, características de células trofoblásticas. Envolvendo o embrião visualizou-se o saco amniótico constituído de duas camadas passíveis de separação mecânica, que apresentaram morfologia similar, sendo formadas por um epitélio pavimentoso avascular. Não foi observado saco vitelino no estágio gestacional do espécime estudado. Conclui-se que a placenta de M. gouazoubira é oligocotiledonária, como observado em outros cervídeos, e que as membranas fetais apresentam semelhanças com a de outros ruminantes, incluindo as características citológicas. Estudos adicionais são necessários para determinar a presença do saco vitelino e quando ocorre sua regressão.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eletrorretinograma (ERG) é o meio diagnóstico objetivo e não-invasivo para avaliar a função retiniana e detectar precocemente, em várias espécies, lesões nas suas camadas mais externas. As indicações mais comuns para ERG em cães são: avaliação pré-cirúrgica de pacientes com catarata, caracterização de distúrbios que causam cegueira, além de servir como importante modelo para o estudo da distrofia retiniana que acomete o homem. Vários são os fatores que podem alterar o ERG tais como: eletrorretinógrafo, fonte de estimulação luminosa, tipo do eletrodo, tempo de adaptação ao escuro, tamanho pupilar, opacidade de meios e protocolo de sedação ou anestesia; além da espécie, raça e idade. Objetivou-se com este estudo padronizar o ERG para cães submetidos à sedação, seguindo o protocolo da International Society for Clinical Electrophysiology of Vision (ISCEV), utilizando Ganzfeld e eletrodos Burian Allen. Foram realizados 233 eletrorretinogramas em cães, 147 fêmeas e 86 machos, com idades entre um e 14 anos. Dos 233 cães examinados, 100 apresentavam catarata em diferentes estágios de maturação, 72 eram diabéticos e apresentavam catarata madura ou hipermadura, 26 apresentaram eletrorretinograma compatível com degeneração retiniana progressiva, três apresentaram eletrorretinograma compatível com síndrome da degeneração retiniana adquirida subitamente e 32 não apresentaram lesão retiniana capaz de atenuar as respostas do ERG, sendo considerados normais quanto à função retiniana. A sedação foi capaz de produzir boa imobilização do paciente sem rotacionar o bulbo ocular, permitindo adequada estimulação retiniana bilateralmente, com auxílio do Ganzfeld. O sistema eletrodiagnóstico Veris registrou com sucesso e simultaneamente de ambos os olhos, as cinco respostas preconizadas pela ISCEV. Como o ERG de campo total tornou-se exame fundamental na rotina oftalmológica, sua padronização é indispensável quando se objetiva comparar resultados de laboratórios distintos. A confiabilidade e reprodutibilidade deste protocolo foi demonstrada com a obtenção de registros de ótima qualidade utilizando protocolo padrão da ISCEV, eletrorretinógrafo Veris, Ganzfeld e eletrodos Burian Allen nos cães submetidos à sedação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho teve por objetivo rever a literatura e descrever a utilização da ventilação oscilatória de alta freqüência em crianças e recém-nascidos. Revisão bibliográfica e seleção de publicações mais relevantes sobre ventilação de alta freqüência utilizando as bases de dados MedLine e SciElo publicadas nos últimos 15 anos. As seguintes palavras-chave foram utilizadas: ventilação oscilatória de alta freqüência, ventilação mecânica, síndrome do desconforto respiratório agudo, crianças e recém-nascidos. Descreveu-se o emprego da ventilação oscilatória de alta freqüência em crianças com síndrome do desconforto respiratório agudo, síndrome de escape de ar e doença pulmonar obstrutiva. Avaliou em recém-nascidos, síndrome do desconforto respiratório, displasia broncopulmonar, hemorragia peri-intraventricular, leucoencefalomalácia e extravasamento de ar. Também, abordou a transição da ventilação mecânica convencional para a ventilação de alta freqüência e o manuseio específico da ventilação de alta freqüência quanto à oxigenação, eliminação de gás carbônico, realização de exame radiológico, realização de sucção traqueal e utilização de sedação e bloqueio neuromuscular. Foram abordados o desmame deste modo ventilatório e as complicações. Em crianças maiores a ventilação oscilatória de alta freqüência é uma opção terapêutica, principalmente na síndrome do desconforto respiratório agudo, devendo ser empregada precocemente. Também pode ser útil em casos de síndrome de escape de ar e doença pulmonar obstrutiva. Em recém-nascidos, não há evidências que demonstram superioridade da ventilação oscilatória de alta freqüência em relação à ventilação convencional, sendo a síndrome de escape de ar a única situação clínica em que há evidência de melhores resultados com este modo ventilatório.