60 resultados para Biodegradable Medical Devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Colloidal particles have been used to template the electrosynthesis of several materials, such as semiconductors, metals and alloys. The method allows good control over the thickness of the resulting material by choosing the appropriate charge applied to the system, and it is able to produce high density deposited materials without shrinkage. These materials are a true model of the template structure and, due to the high surface areas obtained, are very promising for use in electrochemical applications. In the present work, the assembly of monodisperse polystyrene templates was conduced over gold, platinum and glassy carbon substrates in order to show the electrodeposition of an oxide, a conducting polymer and a hybrid inorganic-organic material with applications in the supercapacitor and sensor fields. The performances of the resulting nanostructured films have been compared with the analogue bulk material and the results achieved are depicted in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the development of nanoscience, the interest in electrochromism has increased and new assemblies of electrochromic materials at nanoscale leading to higher efficiencies and chromatic contrasts, low switching times and the possibility of color tuning have been developed. These advantages are reached due to the extensive surface area found in nanomaterials and the large amount of organic electrochromic molecules that can be easily attached onto inorganic nanoparticles, as TiO2 or SiO2. Moreover, the direct contact between electrolyte and nanomaterials produces high ionic transfer rates, leading to fast charge compensation, which is essential for high performance electrochromic electrodes. Recently, the layer-by-layer technique was presented as an interesting way to produce different architectures by the combination of both electrochromic nanoparticles and polymers. The present paper shows some of the newest insights into nanochromic science.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blends formed by electrochemical polymerization of polypyrrole (PPy) into polyacrylamide (PAAm) hydrogels were used as devices for controlled drug release. The influence of several parameters in the synthesis, such as type of hydrogel matrix and polymerization conditions was studied by using a fractional factorial design. The final goal was to obtain an adequate device for use in controlled release tests, based on electrochemical potential control. For controlled release tests, Safranin was used as model drug and release curves (amount of drug vs. time) have shown that these blends are promising materials for this use. The optimized blends obtained were characterized by cyclic voltammetry and Raman spectroscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to compare the impact on knowledge and counseling skills of face-to-face and Internet-based oral health training programs on medical students. Participants consisted of 148 (82 percent) of the 180 invited students attending their fifth academic year at the Faculty of Medicine, University of Sao Paulo, Brasil, in 2007. The interventions took place during a three-month training period in the clinical Center for Health Promotion, which comprised part of a clerkship in Internal Medicine. The students were divided into four groups: 1) Control Group (Control), with basic intervention; 2) Brochure Group (Br), with basic intervention plus complete brochure with oral health themes; 3) Cybertutor Group (Cy), with basic intervention plus access to an Internet-based training program about oral health themes; and 4) Cybertutor + Contact Group (Cy+C), the same as Cy plus brief proactive contact with a tutor. The impact of these interventions on student knowledge was measured with pre- and post assessments, and student skills in asking and counseling about oral health were assessed with an objective structured clinical examination (OSCE). Multivariate logistic regression models were applied to identify the odds ratios of scoring above Control's medians on the final assessment and the OSCE. In the results, Cy+C performed significantly better than Control on both the final assessment (OR 9.4; 95% CI 2.7-32.8) and the OSCE (OR 5.6; 95% CI 1.9-16.3) and outperformed all the other groups. The Cy+C group showed the most significant increase in knowledge and the best skills in asking and counseling about oral health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Medical education and training can contribute to the development of depressive symptoms that might lead to possible academic and professional consequences. We aimed to investigate the characteristics of depressive symptoms among 481 medical students (79.8% of the total who matriculated). Methods: The Beck Depression Inventory (BDI) and cluster analyses were used in order to better describe the characteristics of depressive symptoms. Medical education and training in Brazil is divided into basic (1(st) and 2(nd) years), intermediate (3(rd) and 4(th) years), and internship (5(th) and 6(th) years) periods. The study organized each item from the BDI into the following three clusters: affective, cognitive, and somatic. Statistical analyses were performed using analysis of variance (ANOVA) with post-hoc Tukey corrected for multiple comparisons. Results: There were 184 (38.2%) students with depressive symptoms (BDI > 9). The internship period resulted in the highest BDI scores in comparison to both the basic (p < .001) and intermediate (p < .001) periods. Affective, cognitive, and somatic clusters were significantly higher in the internship period. An exploratory analysis of possible risk factors showed that females (p = .020) not having a parent who practiced medicine (p = .016), and the internship period (p = .001) were factors for the development of depressive symptoms. Conclusion: There is a high prevalence towards depressive symptoms among medical students, particularly females, in the internship level, mainly involving the somatic and affective clusters, and not having a parent who practiced medicine. The active assessment of these students in evaluating their depressive symptoms is important in order to prevent the development of co-morbidities and suicide risk.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The rapid progress currently being made in genomic science has created interest in potential clinical applications; however, formal translational research has been limited thus far. Studies of population genetics have demonstrated substantial variation in allele frequencies and haplotype structure at loci of medical relevance and the genetic background of patient cohorts may often be complex. Methods and Findings: To describe the heterogeneity in an unselected clinical sample we used the Affymetrix 6.0 gene array chip to genotype self-identified European Americans (N = 326), African Americans (N = 324) and Hispanics (N = 327) from the medical practice of Mount Sinai Medical Center in Manhattan, NY. Additional data from US minority groups and Brazil were used for external comparison. Substantial variation in ancestral origin was observed for both African Americans and Hispanics; data from the latter group overlapped with both Mexican Americans and Brazilians in the external data sets. A pooled analysis of the African Americans and Hispanics from NY demonstrated a broad continuum of ancestral origin making classification by race/ethnicity uninformative. Selected loci harboring variants associated with medical traits and drug response confirmed substantial within-and between-group heterogeneity. Conclusion: As a consequence of these complementary levels of heterogeneity group labels offered no guidance at the individual level. These findings demonstrate the complexity involved in clinical translation of the results from genome-wide association studies and suggest that in the genomic era conventional racial/ethnic labels are of little value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes three-dimensional microfluidic paper-based analytical devices (3-D mu PADs) that can be programmed (postfabrication) by the user to generate multiple patterns of flow through them. These devices are programmed by pressing single-use 'on' buttons, using a stylus or a ballpoint pen. Pressing a button closes a small space (gap) between two vertically aligned microfluidic channels, and allows fluids to wick from one channel to the other. These devices are simple to fabricate, and are made entirely out of paper and double-sided adhesive tape. Programmable devices expand the capabilities of mu PADs and provide a simple method for controlling the movement of fluids in paper-based channels. They are the conceptual equivalent of field-programmable gate arrays (FPGAs) widely used in electronics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Internet users are increasingly using the worldwide web to search for information relating to their health. This situation makes it necessary to create specialized tools capable of supporting users in their searches. Objective: To apply and compare strategies that were developed to investigate the use of the Portuguese version of Medical Subject Headings (MeSH) for constructing an automated classifier for Brazilian Portuguese-language web-based content within or outside of the field of healthcare, focusing on the lay public. Methods: 3658 Brazilian web pages were used to train the classifier and 606 Brazilian web pages were used to validate it. The strategies proposed were constructed using content-based vector methods for text classification, such that Naive Bayes was used for the task of classifying vector patterns with characteristics obtained through the proposed strategies. Results: A strategy named InDeCS was developed specifically to adapt MeSH for the problem that was put forward. This approach achieved better accuracy for this pattern classification task (0.94 sensitivity, specificity and area under the ROC curve). Conclusions: Because of the significant results achieved by InDeCS, this tool has been successfully applied to the Brazilian healthcare search portal known as Busca Saude. Furthermore, it could be shown that MeSH presents important results when used for the task of classifying web-based content focusing on the lay public. It was also possible to show from this study that MeSH was able to map out mutable non-deterministic characteristics of the web. (c) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a framework to build medical training applications by using virtual reality and a tool that helps the class instantiation of this framework. The main purpose is to make easier the building of virtual reality applications in the medical training area, considering systems to simulate biopsy exams and make available deformation, collision detection, and stereoscopy functionalities. The instantiation of the classes allows quick implementation of the tools for such a purpose, thus reducing errors and offering low cost due to the use of open source tools. Using the instantiation tool, the process of building applications is fast and easy. Therefore, computer programmers can obtain an initial application and adapt it to their needs. This tool allows the user to include, delete, and edit parameters in the functionalities chosen as well as storing these parameters for future use. In order to verify the efficiency of the framework, some case studies are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design of supplementary damping controllers to mitigate the effects of electromechanical oscillations in power systems is a highly complex and time-consuming process, which requires a significant amount of knowledge from the part of the designer. In this study, the authors propose an automatic technique that takes the burden of tuning the controller parameters away from the power engineer and places it on the computer. Unlike other approaches that do the same based on robust control theories or evolutionary computing techniques, our proposed procedure uses an optimisation algorithm that works over a formulation of the classical tuning problem in terms of bilinear matrix inequalities. Using this formulation, it is possible to apply linear matrix inequality solvers to find a solution to the tuning problem via an iterative process, with the advantage that these solvers are widely available and have well-known convergence properties. The proposed algorithm is applied to tune the parameters of supplementary controllers for thyristor controlled series capacitors placed in the New England/New York benchmark test system, aiming at the improvement of the damping factor of inter-area modes, under several different operating conditions. The results of the linear analysis are validated by non-linear simulation and demonstrate the effectiveness of the proposed procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The advantages offered by the electronic component LED (Light Emitting Diode) have resulted in a quick and extensive application of this device in the replacement of incandescent lights. In this combined application, however, the relationship between the design variables and the desired effect or result is very complex and renders it difficult to model using conventional techniques. This paper consists of the development of a technique using artificial neural networks that makes it possible to obtain the luminous intensity values of brake lights using SMD (Surface Mounted Device) LEDs from design data. This technique can be utilized to design any automotive device that uses groups of SMD LEDs. The results of industrial applications using SMD LED are presented to validate the proposed technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a case study on technology assessment for power quality improvement devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to validate this test protocol, the micro-DVR, a reduced power development platform for DVR (dynamic voltage restorer) devices, was tested and the results are discussed based on voltage disturbances standards. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most important recent improvements in cardiology is the use of ventricular assist devices (VADs) to help patients with severe heart diseases, especially when they are indicated to heart transplantation. The Institute Dante Pazzanese of Cardiology has been developing an implantable centrifugal blood pump that will be able to help a sick human heart to keep blood flow and pressure at physiological levels. This device will be used as a totally or partially implantable VAD. Therefore, an improvement on device performance is important for the betterment of the level of interaction with patient`s behavior or conditions. But some failures may occur if the device`s pumping control does not follow the changes in patient`s behavior or conditions. The VAD control system must consider tolerance to faults and have a dynamic adaptation according to patient`s cardiovascular system changes, and also must attend to changes in patient conditions, behavior, or comportments. This work proposes an application of the mechatronic approach to this class of devices based on advanced techniques for control, instrumentation, and automation to define a method for developing a hierarchical supervisory control system that is able to perform VAD control dynamically, automatically, and securely. For this methodology, we used concepts based on Bayesian network for patients` diagnoses, Petri nets to generate a VAD control algorithm, and Safety Instrumented Systems to ensure VAD system security. Applying these concepts, a VAD control system is being built for method effectiveness confirmation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The therapeutic ultrasound (US) is one of the resources mostly used by physiotherapists; however the use of uncalibrated equipments results in inefficient or even harmful therapies to the patient. In this direction, the objective of this study was to evaluate the performance and the procedures of utilization and maintenance of US in use in clinics and Physical-therapy offices. A questionnaire with questions related to the procedures applied in service during the use of therapeutic ultrasound was applied to physiotherapists. The performance of 31 equipments of 6 different brands and 13 different models was evaluated according to the IEC 61689 norm. The parameters measured were: acoustic power; effective radiating area (AER); non-uniformity ratio of the beam (RBN); maximum effective intensity; acoustic frequency of operation, modulation factor and wave form on pulsate mode. As for the questionnaires, it was evident that the professionals are not concerned about the calibration of the equipment. The results demonstrated that only 32.3% of the equipments were in accordance with the norms for the variables power and effective radiation area. The frequency analysis indicated that 20% of the 3 MHz transducers and 12.5% of the 1 MHz contemplated the norms. In the pulsate mode, 12.7% presented relation rest/duration inside allowed limits. A great variation of the ultrasonic field was observed on the obtained images, which presented beams not centered, sometimes with bifurcation of its apex. The results allow concluding that, although used in therapeutic sessions with the population, none of the equipments presents all the analyzed variables inside technical norms. (C) 2010 Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Samples of poly(l,l-lactide)-block-poly(ethylene glycol)-block-poly(l,l-lactide) (PLLA-PEG-PLLA) were synthesized from l,l-lactide polymerization using stannous 2-ethylhexanoate, Sn(Oct)(2) as initiator and di-hydroxy-terminated poly(ethylene glycol) (PEG) (M (n) = 4000 g mol(-1)) as co-initiator. The chemical linkage between the PEG segment and the PLA segments was characterized by Fourier transform infrared spectroscopy (FTIR). Thermogravimetry analysis (TG) revealed the copolymers composition and was capable to show the deleterious effect of an excess of Sn(Oct)(2) in the polymer thermal stability, while Differential Scanning Calorimetry (DSC) allowed the observation of the miscibility between the PLLA and PEG segments in the different copolymers.