256 resultados para Angular coefficient


Relevância:

20.00% 20.00%

Publicador:

Resumo:

New differential linear coherent scattering coefficient, mu(CS), data for four biological tissue types (fat pork, tendon chicken, adipose and fibroglandular human breast tissues) covering a large momentum transfer interval (0.07 <= q <= 70.5 nm(-1)), resulted from combining WAXS and SAXS data, are presented in order to emphasize the need to update the default data-base by including the molecular interference and the large-scale arrangements effect. The results showed that the differential linear coherent scattering coefficient demonstrates influence of the large-scale arrangement, mainly due to collagen fibrils for tendon chicken and fibroglandular breast samples, and triacylglycerides for fat pork and adipose breast samples at low momentum transfer region. While, at high momentum transfer, the mu(CS) reflects effects of molecular interference related to water for tendon chicken and fibroglandular samples and, fatty acids for fat pork and adipose samples. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to investigate the reliability and validity of photogrammetry in measuring the lateral spinal inclination angles. Methods: Forty subjects (32 female and 8 males) with a mean age of 23.4 +/- 11.2 years had their scoliosis evaluated by radiographs of their trunk, determined by the Cobb angle method, and by photogrammetry. The statistical methods used included Cronbach alpha, Pearson/Spearman correlation coefficients, and regression analyses. Results: The Cronbach a values showed that the photogrammetric measures showed high internal consistency, which indicated that the sample was bias free. The radiograph method showed to be more precise with intrarater reliabilities of 0.936, 0.975, and 0.945 for the thoracic, lumbar, and thoracolumbar curves, respectively, and interrater reliabilities of 0.942 and 0.879 for the angular measures of the thoracic and thoracolumbar segments, respectively. The regression analyses revealed a high determination coefficient although limited to the adjusted linear model between the radiographic and photographic measures. It was found that with more severe scoliosis, the lateral curve measures obtained with the photogrammetry were for the thoracic and lumbar regions (R = 0.619 and 0.551). Conclusions: The photogrammetric measures were found to be reproducible in this study and could be used as Supplementary information to decrease the number of radiographs necessary for the monitoring of scoliosis. (J Manipulative Physiol Ther 2009;32:423-430)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In adolescent idiopathic scoliosis (AIS) there has been a shift towards increasing the number of implants and pedicle screws, which has not been proven to improve cosmetic correction. To evaluate if increasing cost of instrumentation correlates with cosmetic correction using clinical photographs. 58 Lenke 1A and B cases from a multicenter AIS database with at least 3 months follow-up of clinical photographs were used for analysis. Cosmetic parameters on PA and forward bending photographs included angular measurements of trunk shift, shoulder balance, rib hump, and ratio measurements of waist line asymmetry. Pre-op and follow-up X-rays were measured for coronal and sagittal deformity parameters. Cost density was calculated by dividing the total cost of instrumentation by the number of vertebrae being fused. Linear regression and spearman`s correlation were used to correlate cost density to X-ray and photo outcomes. Three independent observers verified radiographic and cosmetic parameters for inter/interobserver variability analysis. Average pre-op Cobb angle and instrumented correction were 54A degrees (SD 12.5) and 59% (SD 25) respectively. The average number of vertebrae fused was 10 (SD 1.9). The total cost of spinal instrumentation ranged from $6,769 to $21,274 (Mean $12,662, SD $3,858). There was a weak positive and statistically significant correlation between Cobb angle correction and cost density (r = 0.33, p = 0.01), and no correlation between Cobb angle correction of the uninstrumented lumbar spine and cost density (r = 0.15, p = 0.26). There was no significant correlation between all sagittal X-ray measurements or any of the photo parameters and cost density. There was good to excellent inter/intraobserver variability of all photographic parameters based on the intraclass correlation coefficient (ICC 0.74-0.98). Our method used to measure cosmesis had good to excellent inter/intraobserver variability, and may be an effective tool to objectively assess cosmesis from photographs. Since increasing cost density only improves mildly the Cobb angle correction of the main thoracic curve and not the correction of the uninstrumented spine or any of the cosmetic parameters, one should consider the cost of increasing implant density in Lenke 1A and B curves. In the area of rationalization of health care expenses, this study demonstrates that increasing the number of implants does not improve any relevant cosmetic or radiographic outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The common bean is affected by several pathogens that can cause severe yield losses. Here we report the introgression of resistance genes to anthracnose, angular leaf spot and rust in the `carioca-type` bean cultivar `Ruda`. Initially, four backcross (BC) lines were obtained using `TO`, `AB 136`, `Ouro Negro` and `AND 277` as donor parents. Molecular fingerprinting was used to select the lines genetically closer to the recurrent parent. The relative genetic distances between `Ruda` and the BC lines varied between 0.0% and 1.99%. The BC lines were intercrossed and molecular markers linked to the resistance genes were used to identify the plants containing the genes of interest. These plants were selfed to obtain the F(2), F(3) and F(4) plants which were selected based on the presence of the molecular markers mentioned and resistance was confirmed in the F(4) generation by inoculation. Four F(4:7) pyramid lines with all the resistance genes showed resistance spectra equivalent to those of their respective donor parents. Yield tests showed that these lines are as productive as the best `carioca-type` cultivars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The purpose of this research was to provide further evidence to demonstrate the precision and accuracy of maxillofacial linear and angular measurements obtained by cone-beam computed tomography (CBCT) images. Study design. The study population consisted of 15 dry human skulls that were submitted to CBCT, and 3-dimensional (3D) images were generated. Linear and angular measurements based on conventional craniometric anatomical landmarks, and were identified in 3D-CBCT images by 2 radiologists twice each independently. Subsequently, physical measurements were made by a third examiner using a digital caliper and a digital goniometer. Results. The results demonstrated no statistically significant difference between inter-and intra-examiner analysis. Regarding accuracy test, no statistically significant differences were found of the comparison between the physical and CBCT-based linear and angular measurements for both examiners (P = .968 and .915, P = .844 and .700, respectively). Conclusions. 3D-CBCT images can be used to obtain dimensionally accurate linear and angular measurements from bony maxillofacial structures and landmarks. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 430-436)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. This study was designed to determine the precision and accuracy of angular measurements using three-dimensional computed tomography (3D-CT) volume rendering by computer systems. Study design. The study population consisted of 28 dried skulls that were scanned with a 64-row multislice CT, and 3D-CT images were generated. Angular measurements, (n = 6) based upon conventional craniometric anatomical landmarks (n = 9), were identified independently in 3D-CT images by 2 radiologists, twice each, and were then performed by 3D-CT imaging. Subsequently, physical measurements were made by a third examiner using a Beyond Crysta-C9168 series 900 device. Results. The results demonstrated no statistically significant difference between interexaminer and intraexaminer analysis. The mean difference between the physical and 3-D-based angular measurements was -1.18% and -0.89%, respectively, for both examiners, demonstrating high accuracy. Conclusion. Maxillofacial analysis of angular measurements using 3D-CT volume rendering by 64-row multislice CT is established and can be used for orthodontic and dentofacial orthopedic applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes two similar methods for calculating gamma transition intensities from multidetector coincidence measurements. In the first one, applicable to experiments where the angular correlation function is explicitly fitted, the normalization parameter from this fit is used to determine the gamma transition intensities. In the second, that can be used both in angular correlation or DCO measurements, the spectra obtained for all the detector pairs are summed up, in order to get the best detection statistics possible, and the analysis of the resulting bidimensional spectrum is used to calculate the transition intensities; in this method, the summation of data corresponding to different angles minimizes the influence of the angular correlation coefficient. Both methods are then tested in the calculation of intensities for well-known transitions from a (152)Eu standard source, as well as in the calculation of intensities obtained in beta-decay experiments with (193)Os and (155)Sm sources, yielding excellent results in all these cases. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The angular distributions for elastic scattering and breakup of halo nuclei are analysed using a near-side/far-side decomposition within the framework of the dynamical eikonal approximation. This analysis is performed for (11)Be impinging on Pb at 69 MeV/nucleon. These distributions exhibit very similar features. In particular they are both near-side dominated, as expected from Coulomb-dominated reactions. The general shape of these distributions is sensitive mostly to the projectile-target interactions, but is also affected by the extension of the halo. This suggests the elastic scattering not to be affected by a loss of flux towards the breakup channel. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quadrupolar hyperfine interactions of in-diffused (111)In -> (111)Cd probes in polycrystalline isostructural Zr(4)Al(3) and Hf(4)Al(3) samples containing small admixtures of the phases (Zr/Hf)(3)Al(2) were investigated. A strong preference of (111)In solutes for the contaminant (Zr/Hf)(3)Al(2) minority phases was observed. Detailed calculations of the electric field gradient (EFG) at the Cd nucleus using the full-potential augmented plane wave + local orbital formalism allowed us to assign the observed EFG fractions to the various lattice sites in the (Zr/Hf)(3)Al(2) compounds and to understand the preferential site occupation of the minority phases by the (111)In atoms. The effects of the size of the supercell and relaxation around the oversized In and Cd probe atoms were investigated in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The (16)O+(27)Al elastic and inelastic angular distributions have been measured in a broad angular range (13 degrees < theta(lab) < 52 degrees) at about 100 MeV incident energy. The use of the MAGNEX large acceptance magnetic spectrometer and of the ray-reconstruction analysis technique has been crucial in order to provide, in the same experiment, high-resolution energy spectra and cross-section measurements distributed over more than seven orders of magnitude down to hundreds of nb/sr. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, rotating strings in three directions of AdS(4) x CP(3) geometry are studied; its divergent energy limit, and conserved charges are also determined. An interpretation of these configurations as either giant magnons or spiky strings is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radial transport in the tokamap, which has been proposed as a simple model for the motion in a stochastic plasma, is investigated. A theory for previous numerical findings is presented. The new results are stimulated by the fact that the radial diffusion coefficients is space-dependent. The space-dependence of the transport coefficient has several interesting effects which have not been elucidated so far. Among the new findings are the analytical predictions for the scaling of the mean radial displacement with time and the relation between the Fokker-Planck diffusion coefficient and the diffusion coefficient from the mean square displacement. The applicability to other systems is also discussed. (c) 2009 WILEY-VCH GmbH & Co. KGaA, Weinheim

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: o objetivo deste estudo prospectivo de 32 adolescentes com má oclusão de Classe II, divisão 1, associada a retrognatismo mandibular, tratados com aparelho de Herbst, construído sobre bandas e coroas metálicas, foi avaliar cefalometricamente as possíveis mudanças no padrão de crescimento facial. METODOLOGIA: as telerradiografias laterais foram obtidas ao início do tratamento (T1) e imediatamente após 12 meses de tratamento com o referido aparelho ortopédico (T2). Foram utilizados o quociente de Jarabak e o VERT de Ricketts (modificado) para determinação do padrão facial em T1 e T2. RESULTADOS: utilizando o quociente de Jarabak, os resultados evidenciaram que 27 casos (84,4%) apresentaram padrões hipodivergentes em T1 e permaneceram da mesma forma em T2. Cinco casos (15,6%) apresentaram padrão neutro em T1 e não exibiram mudanças em T2. Quando avaliado o VERT de Ricketts (modificado), não ocorreram mudanças no padrão facial em 31 pacientes. Em apenas um caso ocorreu mudança do tipo facial. CONCLUSÃO: baseado nos resultados obtidos, pode-se concluir que, após 12 meses de tratamento com aparelho de Herbst, não ocorreram mudanças verticais no padrão de crescimento facial dos pacientes estudados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo caracteriza-se epidemiológico-descritivo com objetivo de descrever a evolução temporal dos casos de dengue em Ribeirão Preto, São Paulo, no período de 1994 a 2003, segundo mês de ocorrência e sexo. Os dados foram obtidos junto às fichas de notificação compulsória fornecidas pela Vigilância Epidemiológica da Secretaria Municipal de Saúde do município. Foram obtidos os coeficientes de incidência por 100.000 habitantes, segundo estimativas populacionais do Instituto Brasileiro de Geografia e Estatística. O município viveu uma epidemia de dengue no ano de 2001, quando o coeficiente de incidência chegou a 619,65 casos/100.000 habitantes, sendo que dentre os 5.553 casos encontrados no período estudado, 0,07% ocorreram no ano de 1994, 3,68% em 1995, 4,52% em 1996, 2,40% em 1997, 1,82% em 1998, 5,73% em 1999, 3,75% em 2000, 57,37% em 2001, 6,25% em 2002 e, 14,39% em 2003 . Os meses do ano de maior ocorrência da doença foram de janeiro a maio. Em relação à variável sexo, a proporção entre o número de casos foi de aproximadamente 1:1, mostrando pequenas flutuações de casos de dengue entre homens e mulheres, para todo período estudado. Os resultados apontam a necessidade do desenvolvimento de estudos sobre a temática e reforçam o papel das instituições de ensino na questão da dengue no nosso país.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho avaliou o material de higiene bucal usado em escolas para estabelecer um protocolo às ações de higiene bucal coletiva. O estudo foi dividido em duas etapas: 1ª- 20 responsáveis pelos procedimentos coletivos com escolares de Bauru e São José dos Campos - SP responderam a dois questionários sobre o uso de cinco kits de higiene bucal coletiva. A análise estatística foi realizada através do teste Wilcoxon (p < 0,05); 2ª - 178 escolares de 4 a 8 anos de Bauru e Bariri-SP dispensaram na escova uma quantidade de creme dental e dentifrício líquido para a prática da escovação, a qual foi pesada através de uma balança portátil. A análise estatística foi obtida através do coeficiente de correlação de Pearson e a análise de covariância (p< 0,05). O kit 5 obteve graus de satisfação e muita satisfação quando comparado aos kits 1 a 4. A quantidade de creme dental dispensada pelos escolares foi em média 0,41g (Bauru) e 0,48g (Bariri). Não houve diferença estatística entre os escolares de Bauru e Bariri em relação ao dentifrício líquido (média de 0,15g). O dentifrício líquido, através da "técnica da gota", foi considerado prático, dispensando uma pequena quantidade padronizada. O kit 5 demonstrou ser uma boa alternativa ao estabelecimento de um protocolo de ações em saúde bucal coletiva no SUS.