280 resultados para finite-state transducer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

From May 2007 to March 2008, blood samples were collected from 92 healthy dogs living in 21 households (17 farms in rural area, and 4 homes in urban area) in 6 counties of the State of Espirito Santo, southeastern Brazil. In addition, ticks were collected from these dogs. A mean of 4.4 +/- 3.0 dogs (range: 1-12) were sampled per household; 78 and 14 dogs were from rural and urban areas, respectively. Polymerase chain reaction (PCR) designed to amplify fragments of the 18S rDNA gene of Babesia spp or Hepatozoon spp revealed amplicons of the expected size in 20 (21.7%) dogs for Babesia, and 54 (58.7%) dogs for Hepatozoon. All Babesia-positive dogs were also Hepatozoon-positive. Among the 21 households, 15 (71.4%) from 3 counties had at least one PCR-positive dog, including 13 farms (rural area) and 2 homes (urban area). A total of 40 PCR products from the Hepatozoon-PCR, and 19 products from the Babesia-PCR were submitted to DNA sequencing. All generated sequences from Hepatozoon-PCR were identical to each other, and to corresponding 18S rDNA sequences of H. canis in GenBank. Surprisingly, all generated sequences from the Babesia PCR were also identical to corresponding 18S rDNA sequences of H. canis in GenBank. Dogs from 10 rural and 2 urban households were found infested by Rhipicephalus sanguineus ticks. Immature of Amblyomma cajennense ticks were found in dogs from only 4 rural households (also infested by R. sanguineus). All but one household with R. sanguineus-infested dogs had at least one Hepatozoon-infected dog. Statistical analysis showed that the presence of ticks (i.e. R. sanguineus) infesting dogs in the households was significantly (P < 0.05) associated with at least one PCR-positive dog. There was no significant association (P > 0.05) between PCR-positive dogs and urban or rural households. Canine hepatozoonosis caused by H. canis is a high frequent infection in Espirito Santo, Brazil, where it is possibly vectored by R. sanguineus. Since all infected dogs were found apparently healthy, the pathogenicity of H. canis for dogs in Espirito Santo is yet to be elucidated. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the etiology of canine ehrlichiosis and possible clinical and epidemiological data associated with the infection in 70 dogs suspect of ehrlichiosis attended at the Veterinary Hospital of the Sao Paulo State University in Botucatu city during 2001 and 2002. Dogs were evaluated by clinical-epidemiological and hematological data and molecular analysis by partial amplification and DNA sequencing of the ehrlichial dsb gene. E. canes DNA was amplified and sequenced in 28 (40.0%) dogs. Dogs younger than 12 months old showed significantly higher infection rates (65.0%; P < 0.05). Diarrhea, apathy, and anorexia were the major clinical signs observed in 55.2% (P = 0.05), 47.0% (P > 0.05), and 42.4% (P > 0.05) of the PCR-positive dogs, respectively. Twenty-five anemic (<5.5 x 10(6) RBC.mu L(-1)), and 8 leukopenic (<5.5 x 10(3) WBC.mu L(-1)) dogs were PCR-positive (P > 0.05). All 28 PCR-positive dogs showed thrombocytopenia (<175 x 10(3) platelets.mu L(-1)) and revealed statistical significance (P < 0.05). E. canis was the only Ehrlichia species found in dogs in the studied region, with higher infection rates in younger dogs, and statistically associated with thrombocytopenia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevalence and risk factors for anti-Toxoplasma gondii antibodies were investigated in goats of the Serido Oriental microregion, Rio Grande do Norte state, Northeast region of Brazil. Three hundred and sixty-six blood samples from goats collected by jugular venopuncture were used. For the serologic diagnosis of Toxoplasma gondii infection, the indirect fluorescent-anti body test (IFAT) with cut-off value 1:64 was carried out. The prevalence of anti-T. gondii antibodies was 30.6% [95% CI = 25.9-35.6%] with titers ranging from 1:64 to 1: 16,384. The multivariate logistic regression analysis showed that the risk factors associated to anti-T. gondii antibodies were presence of cats in the herd, extensive/semi-intensive management systems and lack of mineral supplementation. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To evaluate the biaxial and short-beam uniaxial strength tests applied to resin composites based upon their Weibull parameters, fractographic features and stress distribution. Methods. Disk- (15 mm x 1 mm) and beam-shaped specimens (10 mm x 2 mm x 1 mm) of three commercial composites (Concept/Vigodent, CA; Heliomolar/Ivoclar-Vivadent, HE; Z250/3M ESPE, FZ) were prepared. After 48h dry storage at 37 degrees C, disks and beams were submitted to piston-on-three-balls (BI) and three-point bending (UNI) tests, respectively. Data were analyzed by Weibull statistics. Fractured surfaces were observed under stereomicroscope and scanning electron microscope. Maximum principal stress (sigma(1)) distribution was determined by finite element analysis (FEA). Maximum sigma(1-BI) and sigma(1-UNI) were compared to FZ strengths calculated by applying the average failure loads to the analytical equations (sigma(a-BI) and sigma(a-UNI)). Results. For BI, characteristic strengths were: 169.9a (FZ), 122.4b (CA) and 104.8c (HE), and for UNI were: 160.3a (FZ), 98.2b (CA) and 91.6b (HE). Weibull moduli ( m) were similar within the same test. CA and HE presented statistically higher m for BI. Surface pores ( BI) and edge flaws ( UNI) were the most frequent fracture origins. sigma(1-BI) was 14% lower than sigma(a-BI.) sigma(1-UNI) was 43% higher than sigma(a-UNI). Significance. Compared to the short-beam uniaxial test, the biaxial test detected more differences among composites and displayed less data scattering for two of the tested materials. Also, biaxial strength was closer to the material`s strength estimated by FEA. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Upper premolars restored with endodontic posts present a high incidence of vertical root fracture (VRF). Two hypotheses were tested: (1) the smaller mesiodistal diameter favors stress concentration in the root and (2) the lack of an effective bonding between root and post increases the risk of VRF. Using finite element analysis, maximum principal stress was analyzed in 3-dimensional intact upper second premolar models. From the intact models, new models were built including endodontic posts of different elastic modulus (E = 37 or E = 200 GPa) with circular or oval cross-section, either bonded or nonbonded to circular or oval cross-section root canals. The first hypothesis was partially confirmed because the conditions involving nonbonded, low-modulus posts showed lower tensile stress for oval canals compared to circular canals. Tensile stress peaks for the nonbonded models were approximately three times higher than for the bonded or intact models, therefore confirming the second hypothesis. (J Endod 2009;35:117-120)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stress distributions in torsion and wire-loop shear tests were compared using three-dimensional (3-D) linear-elastic finite element method, in an attempt to predict the ideal conditions for testing adhesive strength of dental resin composites to dentin. The torsion test presented lower variability in stress concentration at the adhesive interface with changes in the proportion adhesive thickness/resin composite diameter, as well as lower variability with changes in the resin composite elastic modulus. Moreover, the torsion test eliminated variability from changes in loading distance, and reduced the cohesive fracture tendency in the dentin. The torsion test seems to be more appropriate than wire-loop shear test for testing the resin composite-tooth interface strength. (c) Koninklijke Brill NV, Leiden, 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main issue regarding pediatric audiology diagnosis is determining procedures to configure reliable results which can be used to predict frequency-specific hearing thresholds. Aim: To investigate the correlation between auditory steady-state response (ASSR) with other tests in children with sensorineural hearing loss. Methods: Prospective cross-sectional contemporary cohort study. Twenty-three children (ages 1 to 7; mean, 3 years old) were submitted to ASSR, behavioral audiometry, click audiometry brain stem response (ABR), tone burst ABR, and predicting hearing level from the acoustic reflex. Results: the correlation between behavioral thresholds and ASSR was (0.70- 0.93), for the ABR tone burst it was (0.73 -0.93), for the ABR click it was (0.83-0.89) only at 2k and 4 kHz. The match between the ASSR and the hearing threshold prediction rule was considered moderate. Conclusion: there was a significant correlation between the ASSR and audiometry, as well as between ABR click (2k and 4 kHz) and for the ABR tone burst. The acoustic reflex can be used to add information to diagnosis in children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this study was to explore the therapeutic opportunities of each step of 3-step etch-and-rinse adhesives. Methods: Etch-and-rinse adhesive systems are the oldest of the multi-generation evolution of resin bonding systems. In the 3-step version, they involve acid-etching, priming and application of a separate adhesive. Each step can accomplish multiple goals. Acid-etching, using 32-37% phosphoric acid (pH 0.1-0.4) not only simultaneously etches enamel and dentin, but the low pH kills many residual bacteria. Results: Some etchants include anti-microbial compounds such as benzalkonium chloride that also inhibits matrix metalloproteinases (MMPs) in dentin. Primers are usually water and HEMA-rich solutions that ensure complete expansion of the collagen fibril meshwork and wet the collagen with hydrophilic monomers. However, water alone can re-expand dried dentin and can also serve as a vehicle for protease inhibitors or protein cross-linking agents that may increase the durability of resin-dentin bonds. In the future, ethanol or other water-free solvents may serve as dehydrating primers that may also contain antibacterial quaternary ammonium methacrylates to inhibit dentin MMPs and increase the durability of resin-dentin bonds. The complete evaporation of solvents is nearly impossible. Significance: Manufacturers may need to optimize solvent concentrations. Solvent-free adhesives can seal resin-dentin interfaces with hydrophobic resins that may also contain fluoride and antimicrobial compounds. Etch-and-rinse adhesives produce higher resin-dentin bonds that are more durable than most 1 and 2-step adhesives. Incorporation of protease inhibitors in etchants and/or cross-linking agents in primers may increase the durability of resin-dentin bonds. The therapeutic potential of etch-and-rinse adhesives has yet to be fully exploited. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length. Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation. A vertical static load of 100 N was applied to the cantilever arm at the distances of 10, 15, and 20 mm from the center of the distal abutment and the absolute values of specific deformation were recorded. Different patterns of abutment deformation were observed according to the framework alloy. The Co-Cr alloy framework resulted in higher levels of abutment deformation than the silver-palladium alloy framework. Abutment deformation was higher with longer cantilever extensions. Physical properties of the alloys used for framework interfere with abutment deformations patterns. Excessively long cantilever extensions must be avoided. To cite this article:Jacques LB, Moura MS, Suedam V, Souza EAC, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses.Clin. Oral Impl. Res. 20, 2009; 737-741.doi: 10.1111/j.1600-0501.2009.01712.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.