279 resultados para dynamic parameters identification


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: Claudins, a large family of essential tight junction (TJ) proteins, are abnormally regulated in human carcinomas. The aim of this study was to determine the expression of claudins 1, 2, 3, 4, 5, 7, and 11 in prostate samples from Brazilian patients and correlate it with the clinicopathological features of prostate cancer. Methods: Using a tissue microarray (TMA) of specimens of prostate adenocarcinoma and benign prostatic hyperplasia (BPH) we analysed the expression of claudins 1, 2, 3, 4, 5, 7, and 11 by immunohistochemistry. Results: Claudin 4 was down-regulated and claudins 2, 3, and 5 were overexpressed in prostate adenocarcinomas compared with BPH samples. Expression of claudins 1 and 7 was similar in tumours and BPH samples. Claudin 11 was absent from all prostate samples. Overexpression of claudin 3 was associated with perineural invasion (p = 0.014) and tended to occur in advanced stages of the disease (p = 0.064). Increased expression of claudin 5 was marginally associated with perineural invasion (p = 0.060). Conclusions: Our results suggest that alterations in claudin expression occur in prostate cancer cells, although we have not found an association with the main clinicopathological parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims Claudins are integral transmembrane proteins of the tight junctions, critical for maintaining cell adhesion and polarity. Alterations in the expression of individual claudins have been detected in carcinomas and appear to correlate with tumour progression. Methods In this study, a panel of anti-claudin antibodies (anti-claudins 1, 2, 3, 4, 5 and 7) was employed to map claudin expression in 136 cases of oral squamous cell carcinoma (OSCC) organised in a tissue microarray. Results Claudins were expressed in a reticular pattern up to the prickle layer in normal mucosal epithelium. In OSCC, claudins were strongly present in well-differentiated tumours, they presented mild and low expression in moderately differentiated OSCC, and were negative in poorly differentiated OSCC; the absences of claudin 1 (p = 0.002) and claudin 4 (p<0.001) were associated with moderately/poorly differentiated tumours. Strong expression of claudin 4 was associated with decreased perineural infiltration (p = 0.024). Claudins 5 and 7 were mostly negative or weakly expressed in all cases studied. Expression of claudin 7 was associated with the early clinical stages of the disease, whereas loss of claudin 7 tended to be more frequent in advanced stages of OSCC (p = 0.054). Absence of claudin 7 was also associated with absent vascular infiltration (p = 0.045) and with presence of recurrence (p = 0.052). Conclusions Claudin expression patterns showed a strong correlation with histological type of OSCC; claudin expression was decreased in areas of invasion, and negative in poorly differentiated tumours. This pattern may be related to evolution and prognosis of these tumours, especially in the case of claudin 7, which seems to be associated with a poor prognosis in OSCC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: The objective of this study was to compare the frequency of herpes simplex virus type 1 (HSV-1), Epstein-Barr virus (EBV) and human cytomegalovirus (HCMV) in subgingival plaque, saliva and peripheral blood of HIV-positive and-negative patients with periodontal disease. Materials and Methods: Fifty HIV-positive subjects (23 with gingivitis, 27 with periodontitis) and 50 healthy HIV-negative patients with chronic periodontitis were included in the study. Parameters of probing depth (PD), clinical attachment level (CAL), gingival index and plaque index were recorded. The samples were processed for viral identification by the nested polymerase chain reaction technique. Results: HCMV was the most prevalent virus in HIV-positive (82%) and-negative patients (84%), and the detection in the three samples was similar (p > 0.05). HSV-1 was the least prevalent virus in both groups, being detected in similar frequencies in oral sites and in peripheral blood. EBV-1 was found more frequently in saliva and subgingival plaque of HIV-positive patients than in HIV-negative patients (p <= 0.05). Conclusions: EBV-1 was more frequently recovered in oral sites of HIV-positive patients than in HIV-negative patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To determine the slow crack growth (SCG) and Weibull parameters of five dental ceramics: a vitreous porcelain (V), a leucite-based porcelain (D), a leucite-based glass-ceramic (E1), a lithium disilicate glass-ceramic (E2) and a glass-infiltrated alumina composite (IC). Methods. Eighty disks (empty set 12mm x 1.1mm thick) of each material were constructed according to manufacturers` recommendations and polished. The stress corrosion susceptibility coefficient (n) was obtained by dynamic fatigue test, and specimens were tested in biaxial flexure at five stress rates immersed in artificial saliva at 37 degrees C. Weibull parameters were calculated for the 30 specimens tested at 1MPa/s in artificial saliva at 37 degrees C. The 80 specimens were distributed as follows: 10 for each stress rate (10(-2), 10(-1), 10(1), 10(2) MPa/s), 10 for inert strength (10(2) MPa/s, silicon oil) and 30 for 10(0) MPa/s. Fractographic analysis was also performed to investigate the fracture origin. Results. E2 showed the lowest slow crack growth susceptibility coefficient (17.2), followed by D (20.4) and V (26.3). E1 and IC presented the highest n values (30.1 and 31.1, respectively). Porcelain V presented the lowest Weibull modulus (5.2). All other materials showed similar Weibull modulus values, ranging from 9.4 to 11.7. Fractographic analysis indicated that for porcelain D, glass-ceramics E1 and E2, and composite IC crack deflection was the main toughening mechanism. Significance. This study provides a detailed microstructural and slow crack growth characterization of widely used dental ceramics. This is important from a clinical standpoint to assist the clinician in choosing the best ceramic material for each situation as well as predicting its clinical longevity. It also can be helpful in developing new materials for dental prostheses. (c) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To evaluate the effect of the microstructure on the Weibull and slow crack growth (SCG) parameters and on the lifetime of three ceramics used as framework materials for fixed partial dentures (FPDs) (YZ - Vita In-Ceram YZ; IZ - Vita In-Ceram Zirconia; AL - Vita In-Ceram AL) and of two veneering porcelains (VM7 and VM9). Methods. Bar-shaped specimens were fabricated according to the manufacturer`s instructions. Specimens were tested in three-point flexure in 37 degrees C artificial saliva. Weibull analysis (n = 30) and a constant stress-rate test (n = 10) were used to determine the Weibull modulus (m) and SCG coefficient (n), respectively. Microstructural and fractographic analyzes were performed using SEM. ANOVA and Tukey`s test (alpha = 0.05) were used to statistically analyze data obtained with both microstructural and fractographic analyzes. Results. YZ and AL presented high crystalline content and low porosity (0.1-0.2%). YZ had the highest characteristic strength (sigma(0)) value (911 MPa) followed by AL (488 MPa) and IZ (423 MPa). Lower sigma(0) values were observed for the porcelains (68-75 MPa). Except for IZ and VM7, m values were similar among the ceramic materials. Higher n values were found for YZ (76) and AL (72), followed by IZ (54) and the veneering materials (36-44). Lifetime predictions showed that YZ was the material with the best mechanical performance. The size of the critical flaw was similar among the framework materials (34-48 mu m) and among the porcelains (75-86 mu m). Significance. The microstructure influenced the mechanical and SCG behavior of the studied materials and, consequently, the lifetime predictions. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To evaluate the effect of pH of storage medium on slow crack growth (SCG) parameters of dental porcelains. Methods. Two porcelains were selected: with (UD) and without (VM7) leucite particles, in order to assess if the microstructure would affect the response of the material to the pH variation. Disc specimens were produced following manufacturers` instructions. Specimens were stored in artificial saliva in pHs 3.5, 7.0 or 10.0 for 10 days and after that the fatigue parameters (n: SCG susceptibility coefficient and sigma(0): scaling parameter) were obtained by the dynamic fatigue test using the same pH of storage. Microstructural analysis of the materials was also performed. Results. For VM7, the values of n obtained in the different pHs were similar and varied from 29.9 to 31.2. The sigma(0) value obtained in pH 7.0 for VM7 was higher than that obtained in the other pHs, which were similar. For porcelain UD, n values obtained in pHs 7.0 and 10.0 were similar (40.8 and 39.6, respectively), and higher than that obtained in pH 3.5 (26.5). With respect to sigma(0), the value obtained for porcelain UD in pH 10.0 was lower than those obtained in pHs 3.5 and 7.0, which were similar. Significance. The effect of pH on the stress corrosion susceptibility (n) depended on the porcelain studied. While the n value of VM7 was not affected by the pH, UD presented lower n value in acid pH. For both porcelains, storage in acid or basic pH resulted in strength degradation. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The objective of the study is to investigate the results of the newborn hearing screening program carried out in a Public Hospital in Brazil, in the first 3 years regarding: (1) the prevalence of hearing impairment; (2) the influence of the universal hearing screening program on the age at which the diagnosis of hearing loss is defined; (3) the cost effectiveness of the program; (4) the outcomes, in terms of the age in which the hearing rehabilitation started. Methods: A descriptive study of the first 3 years after starting the universal newborn hearing screening in a Public Hospital of Bauru, Sao Paulo state, Brazil. The screening method consists of a two-stage screening approach with transient otoacoustic emissions (TOAE), conducted by an audiologist. If the outcome in the second-stage screening is REFER, the infant is submitted to diagnostic follow-up testing and intervention at the Audiology and Speech Pathology Clinic at the University of Sao Paulo, campus of Bauru. The evaluation of the costs of the universal newborn hearing screening program per each screened newborn (around 4000/year) was done based on a proposal by the National Center for Hearing Assessment and Management, of the Utah State University, United States of America. Results: 11,466 newborns were submitted to hearing screening, corresponding to 90.52% of the living newborns. The prevalence of sensorineural hearing loss was 0.96:1000. Of the 11 children with sensorineural hearing loss, eight children received hearing aids and five started the therapeutic process before the age of 1. Currently, four children between the ages of 11 months and 2 years old were submitted to cochlear implant surgery. The cost of hearing screening was US$7.00 and the annual cost of the universal newborn hearing screening program was US$26,940.47. Conclusion: The hospital-based universal newborn hearing screening carried out through the Brazilian National Health System is viable, with promising results. However, in a country such as Brazil, which presents large socio-economic differences, the same type of analyses should be performed in several regions, so as to take into account specific aspects, to implement the newborn hearing screening along with the Public System. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early-life environmental events that disrupt the mother-pup relationship may induce profound long-lasting changes on several behavioral and neuroendocrine systems. The neonatal handling procedure, which involves repeated brief maternal separations followed by experimental manipulations, reduces sexual behavior and induces anovulatory estrous cycles in female rats. On the afternoon of proestrus, neonatally handled females show a reduced surge of luteinizing hormone (LH) and an increased content of gonadotropin-releasing hormone in the medial preoptic area (MPOA). In order to detect the possible causes for the reduced ovulation and sexual behavior, the present study aimed to analyze the effects of neonatal handling on noradrenaline (NA) and nitric oxide (NO) levels in the MPOA on the afternoon of proestrus. Neonatal handling reduced MHPG (NA metabolite) levels and MHPG/NA ratio in the MPOA, indicating decreased NAergic activity. Additionally, neonatal handling decreased NO levels, as measured by the metabolites (NO x), nitrite and nitrate in the same period. We may conclude that the neonatal handling procedure decreased activity of the NAergic and NOergic systems in the MPOA during proestrus, which is involved in the control of LH and FSH secretion, and this may possibly explain the anovulatory estrous cycles and reduced sexual behavior of the neonatally handled female rats. Copyright (c) 2007 S. Karger AG, Basel.