276 resultados para CR 864.4 R741u


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length. Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation. A vertical static load of 100 N was applied to the cantilever arm at the distances of 10, 15, and 20 mm from the center of the distal abutment and the absolute values of specific deformation were recorded. Different patterns of abutment deformation were observed according to the framework alloy. The Co-Cr alloy framework resulted in higher levels of abutment deformation than the silver-palladium alloy framework. Abutment deformation was higher with longer cantilever extensions. Physical properties of the alloys used for framework interfere with abutment deformations patterns. Excessively long cantilever extensions must be avoided. To cite this article:Jacques LB, Moura MS, Suedam V, Souza EAC, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses.Clin. Oral Impl. Res. 20, 2009; 737-741.doi: 10.1111/j.1600-0501.2009.01712.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This in vitro study aimed to analyse the effect of a single application of TiF(4) and NaF varnishes and solutions to protect against dentin erosion. Methods: Bovine root dentin samples were pre-treated with NaF-Duraphat varnish (2.26%F, pH 4.5), NaF/CaF(2)-Duofluorid varnish (5.63%F, pH 8.0), NaF-experimental varnish (2.45%F, pH 4.5), TiF(4)-experimental varnish (2.45%F, pH 1.2), NaF solution (2.26%F, pH 4.5), TiF(4) solution (2.45%F, pH 1.2) and placebo varnish (pH 5.0, no-F varnish control). Controls remained untreated. Ten samples in each group were then subjected to an erosive demineralisation (Sprite Zero, 4x 90 s/day) and remineralisation (artificial saliva, between the erosive cycles) cycling for S days. Dentin loss was measured profilometrically after pretreatment and after 1, 3 and 5 days of de-remineralisation cycling. The data were statistically analysed by two-way ANOVA and Bonferroni`s post hoc test (p < 0.05). Results: After pre-treatment, TiF(4) solution significantly induced surface loss (1.08 +/- 0.53 mu m). Only Duraphat reduced the dentin loss overtime, but it did not significantly differ from placebo varnish (at 3rd and 5th days) and TiF(4) varnish (at 3rd day). Conclusions: Duraphat varnish seems to be the best option to partially reduce dentin erosion. However, the maintenance of the effects of this treatment after successive erosive challenges is limited. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: The aim of this study was to evaluate the vestibular-palatal diffusion of 4% articaine with epinephrine 1: 100,000 and 1: 200,000, in impacted maxillary third molar extractions, without palatal injection. Materials and Method: Two hundred teeth were selected from patients age 15 to 46. Patients were divided into 4 groups: 1A, were anesthetized with 4% articaine 1: 100,000 and the surgery was initiated 5 minutes following anesthesia. 1B, used 4% articaine 1: 100,000 but the surgery was started 10 minutes after anesthesia. 2A, used 4% articaine 1: 200,000 the surgery was started 5 minutes after. 2B, used 4% articaine 1: 200,000 but 10 minutes was allowed for anesthetic diffusion before the initiation of in groups (50 extractions each) only buccal vestibule anesthesia was initially administered (i.e. no palatal injections were used). Results: The rate of sufficient vestibule-palatal diffusion, as determined by the lack of necessity of supplemental palatal anesthesia, was: 1A(84%), 1B(98%), 2A(78%), 2B(82%). Chi-square (X2) and residual analyses showed that a higher vestibule-palatal diffusion was obtained using 4% articaine 1: 100,000 with a period of 10 minutes (p<0.05). Conclusions: Most of the extractions could be performed only with vestibule anesthesia. However, vasoconstrictor concentration and the time interval between administration of the anesthetic and initiation of surgery did influence buccal vestibule-palatal diffusion of 4% articaine in the extraction models used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study compared the clinical efficacy of 4% articaine (A200) and 0.5% bupivacaine (B200), both with 1: 200,000 epinephrine, for lower third molar removal. Study design: Fifty patients underwent removal of symmetrically positioned lower third molars, in 2 separate appointments, under local anesthesia either with A200 or B200, in a double-blind, randomized, and crossover manner. Time to onset, duration of postoperative analgesia, duration of anesthetic action on soft tissues, intraoperative bleeding, and hemodynamic parameters were evaluated. Results: A statistically significant difference between the time to onset of A200 (1.66 +/- 0.13 minutes) and B200 (2.51 +/- 0.21 minutes) was found (P < .05). There was no statistically significant difference in the duration of analgesia, whether the patient was subjected to osteotomy or not, regardless of the local anesthetic used (3 to 4 hours; P < .05). However, when patients received B200 they experienced a statistically significant longer period of anesthesia on the soft tissues as compared with when they had received A200 (around 5 hours and 4 hours, respectively, P < .05). The surgeon`s rating of intraoperative bleeding was considered very close to minimal for both anesthetics. In the surgeries with osteotomy, the comparison between A200 and B200 showed statistically significant differences in the diastolic (64 mm Hg and 68 mm Hg, respectively, P = .001) and mean arterial pressure (86 mm Hg and 89 mm Hg, respectively, P = .031) when data from all the surgical phases were pooled. Additionally, the mouth opening at the suture removal was statistically different for A200 and B200 solutions (91.90% +/- 3.00% and 88.57% +/- 2.38% of the preoperative measure, respectively) when surgeries required bone removal (P < .05). Conclusions: In comparison with 0.5% bupivacaine, 4% articaine (both with 1: 200,000 epinephrine) provided a shorter time to onset and comparable hemostasis and postoperative pain control with a shorter duration of soft tissue anesthesia in lower third molar removal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many studies have shown that deficits in olfactory and cognitive functions precede the classical motor symptoms seen in Parkinson`s disease (PD) and that olfactory testing may contribute to the early diagnosis of this disorder. Although the primary cause of PD is still unknown, epidemiological studies have revealed that its incidence is increased in consequence of exposure to certain environmental toxins. In this study, most of the impairments presented by C57BL/6 mice infused with a single intranasal (i.n.) administration of the proneurotoxin 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP) (1 mg/nostril) were similar to those observed during the early phase of PD, when a moderate loss of nigral dopamine neurons results in olfactory and memory deficits with no major motor impairments. Such infusion decreased the levels of the enzyme tyrosine hydroxylase in the olfactory bulb, striatum, and substantia nigra by means of apoptotic mechanisms, reducing dopamine concentration in different brain structures such as olfactory bulb, striatum, and prefrontal cortex, but not in the hippocampus. These findings reinforce the notion that the olfactory system represents a particularly sensitive route for the transport of neurotoxins into the central nervous system that may be related to the etiology of PD. These results also provide new insights in experimental models of PD, indicating that the i.n. administration of MPTP represents a valuable mouse model for the study of the early stages of PD and for testing new therapeutic strategies to restore sensorial and cognitive processes in PD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Dental fractures can occur in endodontically treated teeth restored with posts. Purpose. The purpose of this study was to evaluate the in vitro fracture resistance of roots with glass-fiber and metal posts of different lengths. Material and methods. Sixty endodontically treated maxillary canines were embedded in acrylic resin, except for 4 mm of the cervical area, after removing the clinical crowns. The post spaces were opened with a cylindrical bur at low speed attached to a surveyor, resulting in preparations with lengths of 6 mm (group 6 mm), 8 mm (group 8 mm), or 10 mm (group 10 mm). Each group was divided into 2 subgroups according to the post material: cast post and core or glass-fiber post (n=30). The posts were luted with dual-polymerizing resin cement (Panavia F). Cast posts and cores of Co-Cr (Resilient Plus) crowns were made and cemented with zinc phosphate. Specimens were subjected to increasing compressive load (N) until fracture. Data were analyzed with 2-way ANOVA and the Tukey-Kramer test (alpha=.05). Results. The ANOVA analysis indicated significant differences (P<.05) among the groups, and the Tukey test revealed no significant difference among the metal posts of 6-mm length (26.5 N +/- 13.4), 8-mm length (25.2 N +/- 13.9), and 10-mm length (17.1 N +/- 5.2). Also, in the glass-fiber post group, there was no significant difference when posts of 8-mm length (13.4 N +/- 11.0) were compared with the 6-mm (6.9 N +/- 4.6) and 10-mm (31.7 N +/- 13.1) groups. The 10-mm-long post displayed superior fracture resistance, and the 6-mm-long post showed significantly lower mean values (P<.001). Conclusions. Within the limitations of this study, it was concluded that the glass-fiber post represents a viable alternative to the cast metal post, increasing the resistance to fracture of endodontically treated canines. (J Prosthet Dent 2009;101:183-188)