351 resultados para QUANTITATIVE CHARACTERIZATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Xylanases (EC 3.2.1.8) hydrolyze xylan, one of the most abundant plant polysaccharides found in nature, and have many potential applications in biotechnology. Methods: Molecular dynamics simulations were used to investigate the effects of temperature between 298 to 338 K and xylobiose binding on residues located in the substrate-binding cleft of the family 11 xylanase from Bacillus circulans (BcX). Results: In the absence of xylobiose the BcX exhibits temperature dependent movement of the thumb region which adopts an open conformation exposing the active site at the optimum catalytic temperature (328 K). In the presence of substrate, the thumb region restricts access to the active site at all temperatures, and this conformation is maintained by substrate/protein hydrogen bonds involving active site residues, including hydrogen bonds between Tyr69 and the 2` hydroxyl group of the substrate. Substrate access to the active site is regulated by temperature dependent motions that are restricted to the thumb region, and the BcX/substrate complex is stabilized by extensive intermolecular hydrogen bonding with residues in the active site. General significance: These results call for a revision of both the ""hinge-bending"" model for the activity of group 11 xylanases, and the role of Tyr69 in the catalytic mechanism. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interactions between phosphorylcholine-substituted chitosans (PC-CH) and calf-thymus DNA (ct-DNA) were investigated focusing on the effects of the charge ratio, the pH, and phosphorylcholine content on the size and stability of the complexes using the ethidium bromide fluorescence assay, gel electrophoresis, dynamic light scattering. and fluorescence microscopy. The size and colloidal stability of deacetylated chitosan (CH/DNA) and PC-CH/DNA complexes were strongly dependent on phosphorylcholine content, charge ratios, and pH. The interaction strengths were evaluated from ethidium bromide fluorescence, and at N/P ratios higher than 5.0, no DNA release was observed in any synthesized PC-CH/DNA polyplexes by gel electrophoresis. The PC-CH/DNA polyplexes exhibited a higher resistance to aggregation compared to deacetylated chitosan (CH) at neutral pH. At low pH values highly charged chitosan and its phosphorylcholine derivatives had strong binding affinity with DNA, whereas at higher pH Values CH formed large aggregates and only C-CH derivatives were able to form small nanoparticles with hydrodynamic radii varying from 100 to 150 nm. Nanoparticles synthesized at low ionic strength with PC-CH derivatives containing moderate degrees of substitution (DS = 20% and 40%) remained stable for weeks. Photomicroscopies also confirmed that rhodamine-labeled PC(40)CH derivative nanoparticles presented higher colloidal stability than those synthesized using deacetylated chitosan. Accordingly, due to their improved physicochemical properties these phosphorylcholine-modified chitosans provide new perspectives for controlling the properties of polyplexes. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The trans-[RUCl(2)(L)(4)], trans-[Ru(NO)Cl (L)(4)](PF(6))(2) (L = isonicotinamide and 4-acetylpyridine) and trans-[Ru(NO)(OH)(py)(4)]Cl(2) (py = pyridine) complexes have been prepared and characterized by elemental analysis, UV-visible, infrared, and (1)H NMR spectroscopies, and cyclic voltammetry. The MLCT band energies of trans-[RUCl(2)(L)(4) increase in the order 4-acpy < isn < py. The reduction potentials of trans-[RuCl(2)(L)(4)] and trans-[Ru(NO)Cl(L)(4)](2+) increase in the order py < isn < 4-acpy. The stretching band frequency. v(NO), of the nitrosyl complexes ranges from 1913 to 1852 cm(-1) indicating a nitrosonium character for the NO ligand. Due to the large pi-acceptor ability of the equatorial ligands, the coordinated water is much more acidic in the water soluble trans-[Ru(NO)(H(2)O)(py)(4)](3+) than in trans-[Ru(NO)(H(2)O)(NH(3))(4)](3+) (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The elevated plus-maze is a device widely used to assess rodent anxiety under the effect of several treatments, including pharmacological agents. The animal is placed at the center of the apparatus, which consists of two open arms and two arms enclosed by walls, and the number of entries and duration of stay in each arm are measured for a 5-min exposure period. The effect of an anxiolytic drug is to increase the percentage of time spent and number of entries into the open arms. In this work, we propose a new measure of anxiety levels in the rat submitted to the elevated plus-maze. We represented the spatial structure of the elevated plus-maze in terms of a directed graph and studied the statistics of the rat`s transitions between the nodes of the graph. By counting the number of times each transition is made and ordering them in descending frequency we represented the rat`s behavior in a rank-frequency plot. Our results suggest that the curves obtained under different pharmacological conditions can be well fitted by a power law with an exponent sensitive to both the drug type and the dose used. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The elevated plus-maze is an animal model of anxiety used to study the effect of different drugs on the behavior of the animal It consists of a plus-shaped maze with two open and two closed arms elevated 50 cm from the floor The standard measures used to characterize exploratory behavior in the elevated plus-maze are the time spent and the number of entries in the open arms In this work we use Markov chains to characterize the exploratory behavior of the rat in the elevated plus-maze under three different conditions normal and under the effects of anxiogenic and anxiolytic drugs The spatial structure of the elevated plus-maze is divided into squares which are associated with states of a Markov chain By counting the frequencies of transitions between states during 5-min sessions in the elevated plus-maze we constructed stochastic matrices for the three conditions studied The stochastic matrices show specific patterns which correspond to the observed behaviors of the rat under the three different conditions For the control group the stochastic matrix shows a clear preference for places in the closed arms This preference is enhanced for the anxiogenic group For the anxiolytic group the stochastic matrix shows a pattern similar to a random walk Our results suggest that Markov chains can be used together with the standard measures to characterize the rat behavior in the elevated plus-maze (C) 2010 Elsevier B V All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An extracellular polygalacturonase (PG) produced from Paecilomyces variotii was purified to homogeneity through two chromatography steps using DEAE-Fractogel and Sephadex G-100. The molecular weight of P. variotii PG was 77,300 Da by gel filtration and SDS-PAGE. PG had isoelectric point of 4.37 and optimum pH 4.0. PG was very stable from pH 3.0 to 6.0. The extent of hydrolysis of different pectins by the purified enzyme was decreased with an increase in the degree of esterification. PG had no activity toward non-pectic polysaccharides. The apparent K (m) and V (max) values for hydrolyzing sodium polypectate were 1.84 mg/mL and 432 A mu mol/min/mg, respectively. PG was found to have temperature optimum at 65 A degrees C and was totally stable at 45 A degrees C for 90 min. Half-life at 55 A degrees C was 50.6 min. Almost all the examined metal cations showed partial inhibitory effects under enzymatic activity, except for Na(+1), K(+1), and Co(+2) (1 mM) and Cu(+2) (1 and 10 mM).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate patients with Diabetes Mellitus type 2 and painful peripheral neuropathy in order to investigate oral complaints and facial somatosensory findings. Research design and methods: Case-control study; 29 patients (12 women, mean age 57.86 yo) with Diabetes Mellitus type 2 and 31 age-gender-matched controls were evaluated with a standardized protocol for general characteristics, orofacial pain, research diagnostic criteria for temporomandibular disorders, visual analogue scale and McGill Pain questionnaire, and a systematic protocol of quantitative sensory testing for bilateral facial sensitivity at the areas innervated by the trigeminal branches, which included the thermal detection by ThermoSensi 2, tactile evaluation with vonFrey filaments, and superficial pain thresholds with a superficial algometer (Micromar). Statistical analysis was performed with Wilcoxon, chi-square, confidence intervals and Spearman (p < 0.05). Results: Orofacial pain was reported by 55.2% of patients, and the most common descriptor was fatigue (50%); 17.2% had burning mouth. Myofascial temporomandibular disorders were diagnosed in 9(31%) patients. The study group showed higher sensory thresholds of pain at the right maxillary branch (p = 0.017) but sensorial differences were not associated with pain (p = 0.608). Glycemia and HbA(1c) were positively correlated with the quantitative sensory testing results of pain (p < 0.05) and cold (p = 0.044) perceptions. Higher pain thresholds were correlated with higher glycemia and glycated hemoglobin (p = 0.027 and p = 0.026). Conclusions: There was a high prevalence of orofacial pain and burning mouth was the most common complaint. The association of loss of pain sensation and higher glycemia and glycated hemoglobin can be of clinical use for the follow-up of DM complications. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anemia screening before blood donation requires an accurate, quick, practical, and easy method with minimal discomfort for the donors. The aim of this study was to compare the accuracy of two quantitative methods of anemia screening: the HemoCue 201(+) (Aktiebolaget Leo Diagnostics) hemoglobin (Hb) and microhematocrit (micro-Hct) tests. Two blood samples of a single fingerstick were obtained from 969 unselected potential female donors to determine the Hb by HemoCue 201(+) and micro-Hct using HemataSTAT II (Separation Technology, Inc.), in alternating order. From each participant, a venous blood sample was drawn and run in an automatic hematology analyzer (ABX Pentra 60, ABX Diagnostics). Considering results of ABX Pentra 60 as true values, the sensitivity and specificity of HemoCue 201(+) and micro-Hct as screening methods were compared, using a venous Hb level of 12.0 g per dL as cutoff for anemia. The sensitivities of the HemoCue 201(+) and HemataSTAT II in detecting anemia were 56 percent (95% confidence interval [CI], 46.1%-65.5%) and 39.5 percent (95% CI, 30.2%-49.3%), respectively (p < 0.001). Analyzing only candidates with a venous Hb level lower than 11.0 g per dL, the deferral rate was 100 percent by HemoCue 201(+) and 77 percent by HemataSTAT II. The specificities of the methods were 93.5 and 93.2 percent, respectively. The HemoCue 201(+) showed greater discriminating power for detecting anemia in prospective blood donors than the micro-Hct method. Both presented equivalent deferral error rates of nonanemic potential donors. Compared to the micro-Hct, HemoCue 201(+) reduces the risk of anemic female donors giving blood, specially for those with lower Hb levels, without increasing the deferral of nonanemic potential donors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Current relevance of T-wave alternans is based on its association with electrical disorder and elevated cardiac risk. Quantitative reports would improve understanding on TWA augmentation mechanisms during mental stress or prior to tachyarrhythmias. However, little information is available about quantitative TWA values in clinical populations. This study aims to create and compare TWA profiles of healthy subjects and ICD patients, evaluated on treadmill stress protocols. Methods: Apparently healthy subjects, not in use of any medication were recruited. All eligible ICD patients were capable of performing an attenuated stress test. TWA analysis was performed during a 15-lead treadmill test. The derived comparative profile consisted of TWA amplitude and its associated heart rate, at rest (baseline) and at peak TWA value. Chi-square or Mann-Whitney tests were used with p values <= 0.05. Discriminatory performance was evaluated by a binary logistic regression model. Results: 31 healthy subjects (8F, 23M) and 32 ICD patients (10F, 22M) were different on baseline TWA (1 +/- 2 mu V; 8 +/- 9 mu V; p < 0.001) and peak TWA values (26 +/- 13 mu V; 37 +/- 20 mu V; p = 0,009) as well as on baseline TWA heart rate (79 +/- 10 bpm; 67 +/- 15 bpm; p < 0.001) and peak TWA heart rate (118 +/- 8 bpm; 90 +/- 17 bpm; p < 0.001). The logistic model yielded sensitivity and specificity values of 88.9% and 92.9%, respectively. Conclusions: Healthy subjects and ICD patients have distinct TWA profiles. The new TWA profile representation (in amplitude-heart rate pairs) may help comparison among different research protocols. Ann Noninvasive Electrocardiol 2009;14(2):108-118.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Mast cells (MCs) are related with healing process in chronic inflammatory diseases, although in cutaneous leishmaniasis (CL) its importance is unknown. The aim of this study was to determine the correlation of MC with clinical findings in patients with the localized form of CL. Methods A cohort of 85 patients with CL was evaluated. MCs count was performed in pre-treatment biopsies and correlation with clinical findings and Leishmania species determined by PCR were performed. Results The MCs count in patients with CL caused by Leishmania (V.) braziliensis was 14.3 +/- 9.8 cells/mm(2), and 7.0 +/- 6.5 cells/mm(2) in patients with L. (L.) amazonensis (P < 0.05). The linear regression of MCs count with the age showed a tendency of cell number decreasing, according to ageing of the patient (r(2) = 0.05; P < 0.05). The association of disease`s duration and MCs count was positive (r(2) = 0.11; P < 0.05). There was not any association of MCs count with number of lesions neither with Leishmania antigen expression. The MCs count was higher in patients with earlier healing after treatment (P < 0.05). Conclusion MC can be important in CL and related with healing lesion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To identify papillary thyroid carcinoma (PTC)-associated transcripts, we compared the gene expression profiles of three Serial Analysis of Gene Expression libraries generated from thyroid tumors and a normal thyroid tissue. Experimental Design: Selected transcripts were validated in a panel of 57 thyroid tumors using quantitative PCR (qPCR). An independent set of 71 paraffin-embedded sections was used for validation using immunohistochemical analysis. To determine if PTC-associated gene expression could predict lymph node involvement, a separate cohort of 130 primary PTC (54 metastatic and 76 nonmetastatic) was investigated. The BRAF(V600E) mutational status was compared with qPCR data to identify genes that might be regulated by abnormal BRAF/MEK/extracellular signal-regulated kinase signaling. Results: We identified and validated new PTC-associated transcripts. Three genes (CST6, CXCL14, and DHRS3) are strongly associated with PTC. Immunohistochemical analysis of CXCL14 confirmed the qPCR data and showed protein expression in PTC epithelial cells. We also observed that CST6, CXCL14, DHRS3, and SPP1 were associated with PTC lymph node metastasis, with CST6, CXCL14, and SPP1 being positively correlated with metastasis and DHRS3 being negatively correlated. Finally, we found a strong correlation between CST6 and CXCL14 expression and BRAF(V600E) mutational status, suggesting that these genes may be induced subsequently to BRAF activation and therefore may be downstream in the BRAF/MEK/extracellular signal-regulated kinase signaling pathway. Conclusion: CST6, CXCL14, DHRS3, and SPP1 may play a role in PTC pathogenesis and progression and are possible molecular targets for FTC therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contrast echocardiography has been demonstrated useful for left ventricular opacification and improvement of endocardial border delineation. Another important clinical application of this technique refers to the better characterization of cardiac tumors and masses. We here described an asymptomatic patient with cystic mass attached to submitral valve apparatus in which contrast echocardiography was performed after intravenous injection of lipid-encapsulated microbubbles. It resulted in enhancement of the cystic borders and allowed for better definition of its diagnosis. Multislice computed tomography confirmed the echocardiographic findings. This case illustrates the potential of contrast echocardiography to improve the anatomic evaluation of cardiac masses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: There remains significant concern about the long-term safety of drug-eluting stents (DES). However, bare metal stents (BMS) have been used safely for over two decades. There is therefore a pressing need to explore alternative strategies for reducing restenosis with BMS. This study was designed to examine whether IVUS-guided cutting balloon angioplasty (CBA) with BMS could convey similar restenosis rates to DES. Methods and results: In the randomised REstenosis reDUction by Cutting balloon angioplasty Evaluation (REDUCE III) study, 521 patients were divided into four groups based on device and IVUS use before BMS (IVUS-CBA-BMS: 137 patients; Angio-CBA-BMS: 123; IVUS-BA-BMS: 142; and Angio-BA-BMS: 119). At follow-up, the IVUS-CBA-BMS group had a significantly lower restenosis rate (6.6%) than the other groups (p=0.016). We performed a quantitative coronary angiography (QCA) based matched comparison between an IVUS-guided CBA-BMS strategy (REDUCE III) and a DES strategy (Rapamycin-Eluting-Stent Evaluation At Rotterdam Cardiology. Hospital, the RESEARCH study). We matched the presence of diabetes, vessel size, and lesion severity by QCA. Restenosis (>50% diameter stenosis at follow-up) and target vessel revascularisation (TVR) were examined. QCA-matched comparison resulted in 120-paired lesions. While acute gain was significantly greater in IVUS-CBA-BMS than DES (1.65 +/- 0.41 mm vs. 1.28 +/- 0.57 mm, p=0.001), late loss was significantly less with DES than with IVUS-CBA-BMS (0.03 +/- 0.42 mm vs. 0.80 +/- 0.47 mm, p=0.001). However, no difference was found in restenosis rates (IVUS-CBA-BMS: 6.6% vs. DES: 5.0%, p=0.582) and TVR (6.6% and 6.6%, respectively). Conclusions: An IVUS-guided CBA-BMS strategy yielded restenosis rates similar to those achieved by DES and provided an effective alternative to the use of DES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The phospholipases A(1) (PLA(1)s) from the venom of the social wasp Polybia paulista occur as a mixture of different molecular forms. To characterize the molecular origin of these structural differences, an experimental strategy was planned combining the isolation of the pool of PLAs from the wasp venom with proteomic approaches by using 2-D, MALDI-TOF-TOF MS and classical protocols of protein chemistry, which included N- and C-terminal sequencing. The existence of an intact form of PLA(1) and seven truncated forms was identified, apparently originating from controlled proteolysis of the intact protein; in addition to this, four of these truncated forms also presented carbohydrates attached to their molecules. Some of these forms are immunoreactive to specific-IgE, while others are not. These observations permit to raise the hypothesis that naturally occurring proteolysis of PLA(1), combined with protein glycosylation may create a series of different molecular forms of these proteins, with different levels of allergenicity. Two forms of PLA(2)s, apparently related to each other, were also identified; however, it was not possible to determine the molecular origin of the differences between both forms, except that one of them was glycosylated. None of these forms were immunoreactive to human specific IgE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our aim was to characterize HDL subspecies and fat-soluble vitamin levels in a kindred with familial apolipoprotein A-I (apoA-I) deficiency. Sequencing of the APOA1 gene revealed a nonsense mutation at codon 22, Q[22] X, with two documented homozygotes, eight heterozygotes, and two normal subjects in the kindred. Homozygotes presented markedly decreased HDL cholesterol levels, undetectable plasma apoA-1, tuboeruptive and planar xanthomas, mild corneal arcus and opacification, and severe premature coronary artery disease. In both homozygotes, analysis of HDL particles by two-dimensional gel electrophoresis revealed undetectable apoA-I, decreased amounts of small a-3 migrating apoA-II particles, and only modestly decreased normal amounts of slow a migrating apoA-IV- and apoE-containing HDL, while in the eight heterozygotes, there was loss of large alpha-1 HDL particles. There were no significant decreases in plasma fat-soluble vitamin levels noted in either homozygotes or heterozygotes compared with normal control subjects. Our data indicate that isolated apoA-I deficiency results in marked HDL deficiency with very low apoA-II alpha-3 HDL particles, modest reductions in the separate and distinct plasma apoA-IV and apoE HDL particles, tuboeruptive xanthomas, premature coronary atherosclerosis, and no evidence of fat malabsorption.