305 resultados para novel dual-slab laser
Resumo:
PURPOSE: To analyze the effects of variations in femtosecond laser energy level on corneal stromal cell death. and inflammatory cell influx following flap creation in a rabbit model. METHODS: Eighteen rabbits were stratified in three different groups according to level of energy applied for flap creation (six animals per group). Three different energy levels were chosen for both the lamellar and side cut; 2.7 mu J (high energy), 1.6 mu J (intermediate energy), and 0.5 mu J (low energy) with a 60 kHz, model II, femtosecond laser (IntraLase). The opposite eye of each rabbit served as a control. At the 24-hour time point after surgery, all rabbits were euthanized and the comeoscleral rims were analyzed for the levels of cell death and inflammatory cell influx with the terminal uridine deoxynucleotidyl transferase dUTP-nick end labeling (TUNEL) assay and immunocytochemistry for monocyte marker CD11b, respectively. RESULTS: The high energy group (31.9 +/- 7.1 [standard error of mean (SEM) 2.9]) had significantly more TUNEL positive cells in the central flap compared to the intermediate (22.2 +/- 1.9 [SEM 0.8], P=.004), low (17.9 +/- 4.0 [SEM 1.6], P <= .001), and control eye (0.06 +/- 0.02 [SEM 0.009], P <= .001) groups. The intermediate and low energy groups also had significantly more TUNEL positive cells than the control groups (P <= .001). The difference between the intermediate and low energy levels was not significant (P=.56). The mean for CD11b-positive cells/400x field at the flap edge was 26.1 +/- 29.3 (SEM 11.9), 5.8 +/- 4.1 (SEM 1.6), 1.6 +/- 4.1 (SEM 1.6), and 0.005 +/- 0.01 (SEM 0.005) for high energy, intermediate energy, low energy, and control groups, respectively. Only the intermediate energy group showed statistically more inflammatory cells than control eyes (P = .015), most likely due to variability between eyes. CONCLUSIONS: Higher energy levels trigger greater cell death when the femtosecond laser is used to create corneal flaps: Greater corneal inflammatory cell infiltration is observed with higher femtosecond laser energy levels. [J Refract Surg. 2009;25:869-874.] doi:10.3928/1081597X-20090917-08
Resumo:
Strategies to minimize the immunogenicity and toxicity of murine anti-CD3 antibodies (e.g. OKT3) are of special interest for organ transplantation and for the treatment of autoimmune diseases. In the present work, we have developed two humanized anti-CD3 antibodies. These molecules were shown to bind to human CD3, though less efficiently, and display less mitogenic activity than CKT3. These results prompted us to investigate whether this reduced mitogenic potential was associated with the development of anti-inflammatory properties. Indeed, in peripheral blood mononuclear cells (PBMCs), the humanized antibody versions induced a predominantly anti-inflammatory cytokine profile, in contrast with the pro-inflammatory profile induced by OKT3. Neither OKT3 nor the humanized versions induced the expression of IL-4, IL-2 or TGF-beta. Both humanized antibodies induced significantly lower production of IFN-gamma and IL-5 and slightly higher production of IL-10 than OKT3. This immunomodulatory profile was most evident by the 80-fold higher ratio of IL-10/IFN-gamma production in PBMCs cultured in the presence of the humanized antibodies, compared to those stimulated with CKT3. Furthermore, these humanized anti-CD3 antibodies induced a late FOXP3 gene expression while OKT3 led to a more transient expression of FOXP3. Taken our results, we suggest that these humanized anti-CD3 antibodies may promote the development of T cells with immunoregulatory activity. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Background Roux-en-Y gastric bypass (RYGB) is amongst the commonest surgical intervention for weight loss in obese patients. Gastrocutaneous fistula, which usually occurs along the vertical staple line of the pouch, is amongst its most alarming complications. Medical management comprised of wound drainage, nutritional support, acid suppression, and antibiotics may be ineffective in as many as a third of patients with this complication. We present outcomes after endoscopic application of SurgiSIS (R), which is a novel biomaterial for the treatment of this complication. Design A case series of 25 patients. Methods Twenty-five patients who had failed conservative medical management of gastrocutaneous fistula after RYGB underwent endoscopic application of SurgiSIS (R)-an acellular fibrogenic matrix biomaterial to help fistula healing. Main outcome measures Fistula closure as assessed by upper gastrointestinal imaging and endoscopic examination. Results In patients who had failed medical management lasting 4-25 (median, 7) weeks, closure of the fistulous tract was successful after one application in six patients (30%), two applications in 11 patients (55%), and three applications in three patients (15%). There were no procedure-related complications. Conclusions Endoscopic application of SurgiSIS (R)-an acellular fibrogenic matrix-is safe and effective for the treatment of gastrocutaneous fistula after RYGB.
Resumo:
Therapeutic approaches to chronic actinic cheilitis focus on the removal or destruction of diseased epithelium. The CO(2) laser has become an important therapeutic alternative, achieving clinical resolution in around 90% of patients. Although many laser physical parameters have been reported, some are known for their low potential for scar induction without compromising the success of the results. The aim of this clinicohistological study was to compare the therapeutic responses to two low-morbidity protocols involving a single laser pass. A total of 40 patients with chronic multicentric and microscopically proven disease were randomly submitted to two conservative CO(2) laser protocols using a bilateral comparative model. The degree of histological atypia of the epithelium was determined in 26 patients both pre- and postoperatively for both protocols. Other histological phenomena were assessed in addition to this central analysis parameter. Clinical recurrence occurred in 12.5% of patients for each protocol, together with a significant reduction in the degree of epithelial atypia (p < 0.001), which was occasionally complete. However, no difference was found between the protocols (p > 0.05). Using these morphological parameters it was not possible to determine whether postoperative epithelial atypias in part of the sample were reactive or residual in nature. A few patients may show minor postoperative lesions. Due to their potential to achieve clinical and importantly microscopic resolution, the studied protocols may be used for mild through moderate dysplastic epithelium and clinically diffuse disease.
Resumo:
Type 1, X-linked Hyper-IgM syndrome (HIGM1) is caused by mutations in the gene encoding the CD154 protein, also known as CD40 ligand (CD40LG). CD40L is expressed in activated T cells and interacts with CD40 receptor expressed on B lymphocytes and dendritic cells. Affected patients present cellular and humoral immune defects, with infections by intracellular, opportunistic and extracellular pathogens. In the present study we investigated the molecular defects underlying disease in four patients with HIGM1. We identified four distinct CD40L mutations, two of them which have not been previously described. P1 harboured the novel p.G227X mutation which abolished CD40L expression. P2 had a previously described frame shift deletion in exon 2 (p.I53fsX65) which also prevented protein expression. P3 demonstrated the previously known p.V126D change in exon 4, affecting the TNF homology (TNFH) domain. Finally, P4 evidenced the novel p.F229L mutation also located in the TNFH domain. In silico analysis of F229L predicted the change to be pathological, affecting the many hydrophobic interactions of this residue. Precise molecular diagnosis in HIGM syndrome allows reliable detection of carriers, making genetic counselling and prenatal diagnosis possible.
Resumo:
Objective: Wolfram syndrome (WS) is a rare, progressive, neurodegenerative disorder with an autosomal recessive pattern of inheritance. The gene for WS, WFS1, was identified on chromosome 4p16 and most WS patients carry mutations in this gene. However. some studies have provided evidence for genetic heterogeneity and the genotype-phenotype relationships are not clear. Our aim was to ascertain the spectrum of WFS1 mutations in Brazilian patients with WS and to examine the phenotype-genotype relationships in these patients. Design and methods: Clinical characterization and analyses of the WFS1. gene were performed in 27 Brazilian patients with WS from 19 families. Results: We identified 15 different mutations in the WFS1 gene in 26 patients, among which nine are novel. All mutations occurred in exon 8, except for one missense mutation which was located in exon 5. Although we did not find any clear phenotype-genotype relationship in patients with mutations in exon 8, the homozygous missense mutation in exon 5 was associated with a mild phenotype: onset of diabetes mellitus and optic atrophy during adulthood with good metabolic control being achieved with low doses of sulfonylurea Conclusions: Our data show that WFS1 is the major gene involved in WS in Brazilian patients and most mutations are concentrated in exon 8. Also, our study increases the spectrum of WFS1 mutations. Although no clear phenotype-genotype relationship was found for mutations in exon 8, a mild phenotype was associated with a homozygous missense mutation in exon 5.
Resumo:
Sacrococcygeal teratoma (SCT) is the commonest solid fetal tumor. Perinatal prognosis is usually favorable, but sometimes it can be complicated by fetal hydrops being responsible for high risk of mortality. Fetal therapy in such cases has so far not been established. We report a case with a giant solid SCT associated with fetal hydrops and severe heart failure. 2D- and 3D-Doppler ultrasonography revealed great vessels originated from the medial sacral artery. Percutaneous laser ablation of these vessels was performed at 24 weeks of gestation. During the procedure, severe anemia was also diagnosed (hemoglobin 4.3 g/dl). Two days later, the fetus died and pathological examination revealed local tumor necrosis and blood hemorrhage inside the mass. We suggest that in such cases, fetal surgery may not be enough, being too late, and perhaps fetal clinical therapy for anemia and heart failure could be the best option at a gestational age of less than 28 weeks. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
PURPOSE: To compare the abilities of scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) and variable corneal compensation (VCC) modes for detection of retinal nerve fiber layer (RNFL) loss in eyes with band atrophy (BA) of the optic nerve. DESIGN. Cross-sectional study. METHODS: Thirty-seven eyes from 37 patients with BA and temporal visual field defect from chiasmal compression and 40 eyes from 40 healthy subjects were studied. Subjects underwent standard automated perimetry and RNFL measurements using an SLP device equipped with VCC and ECC. Receiver operating characteristic (ROC) curves were calculated for each parameter. Pearson correlation coefficients were obtained to evaluate the relationship between RNFL thickness parameters and severity of visual field loss, as assessed by the temporal mean defect. RESULTS: All RNFL thickness parameters were significantly lower in eyes with BA compared with normal eyes with both compensation modes. However, no statistically significant differences were observed in the areas under the ROC curves for the different parameters between GDx VCC and ECC (Carl Zeiss Meditec, Inc, Dublin, California, USA). Structure-function relationships also were similar for both compensation modes. CONCLUSIONS: No significant differences were found between the diagnostic accuracy of GDx ECC and that of VCC for detection of BA of the optic nerve. The use of GDx ECC does not seem to provide a better evaluation of RNFL loss on the temporal and nasal sectors of the peripapillary retina in subjects with BA of the optic nerve.
Resumo:
Background. Periodontal disease is often associated with systemic diseases and is characterized by destruction of the tissues supporting the teeth. Patients using immunosuppressive drugs such as tacrolimus are among those who suffer from tissue destruction. Objective. We sought to evaluate the effects of laser and photodynamic therapies (PDT; nonsurgical) as an adjunct to scaling and rootplaning (SRP) in the treatment of corona-induced periodontitis in rats immunosuppressed with tacrolimus (Prograf). Materials and Methods. The animals were divided into 5 groups. Each groups had 6 rats. Group I, the control group, received only saline solution throughout the study period of 42 days and did not receive periodontal treatment; group II received saline solution and SRP; group III received tacrolimus (1 mg/kg per day) and was treated with SRP; group IV animals were treated identically to group III and then administered laser treatment; and in group V, the animals were treated identically to group III and then administered PDT. Results. Statistical analysis indicated decreased bone loss with the progression of time (P = .035). There was no difference between the bone loss associated with the types of treatment administered to groups I, II, and III (P > .9) or groups IV and V (P > .6). The analysis also indicated that immunosuppression was not a bone loss-determining factor. Conclusion. Laser and PDT therapies were effective as an adjunctive treatment to SRP in reducing bone loss caused by experimental periodontitis induced in animals being treated systemically with tacrolimus.
Resumo:
Background: A 150 cm(3) pear-shaped gastric balloon with a 30 cm-long duodenal stem and a 7 g metallic weight at its distal end was designed and developed to facilitate weight loss by (a) delaying gastric emptying thus enhancing interprandial satiety, and (b) stimulating antral and duodenal receptors of satiation. Methods: Twenty-six patients (body mass index of 29 to 40 kg/m(2)) who failed to lose weight despite dietary intervention underwent endoscopic implantation of the balloon device. Patients were monitored for tolerance to the balloon, complications, weight loss, and compliance with a restricted caloric intake. Results: Six men and 20 women with a median body weight of 93.0kg (range, 73.5 to 119.9), median body mass index 34.3 kg/m(2) (range, 28.8 to 39.5) underwent balloon implantation for a median period of 4.0 months (range, 0.75 to 6.0). Twenty-two patients successfully complied with a 1250 to 1500 kcal daily diet restriction during the study period. Median weight reduction was 6.5 kg (range, 3.7 to 19.9). Patients with initial body weight of > 90 kg tended to loose more weight (8.1 kg) than patients weighing < 90 kg (4.5 kg) (P = 0.14). Nine patients with dwell times of 6 months lost 11.5 +/- 4.6 kg. The balloon malfunctioned in 4 patients (in I patient, the balloon leaked spontaneously but remained in the stomach and in 3 patients, the balloon migrated distally). Conclusions: Our novel balloon device may be effective in inducing weight loss by promoting compliance with a restricted caloric intake and is well tolerated due to its small size. Complications resulted from balloon rupture, which can be easily prevented by enhancements in design and use of alternative materials.
Resumo:
Sepsis is the systemic inflammatory response syndrome secondary to a local infection. Septic shock, the severe complication of sepsis associated with refractory hypotension, is frequently a near-fatal condition requiring prompt diagnosis and management. Although the recent years have been associated with considerable improvements in the knowledge of the pathophysiology of the disease and remarkable advances have been achieved in sepsis treatment, the morbidity and mortality of this disease are still unacceptably high. In this review, we will briefly discuss the ongoing standard treatment of septic shock and describe novel potential therapies, aiming to improve hemodynamic support and/or control inflammatory response in sepsis. These therapies were associated with benefits in experimental studies and have been tested or are currently under testing in randomized controlled studies with septic patients.
Resumo:
Recent studies have investigated whether low level laser therapy (LLLT) can optimize human muscle performance in physical exercise. This study tested the effect of LLLT on muscle performance in physical strength training in humans compared with strength training only. The study involved 36 men (20.8 +/- 2.2 years old), clinically healthy, with a beginner and/or moderate physical activity training pattern. The subjects were randomly distributed into three groups: TLG (training with LLLT), TG (training only) and CG (control). The training for TG and TLG subjects involved the leg-press exercise with a load equal to 80% of one repetition maximum (1RM) in the leg-press test over 12 consecutive weeks. The LLLT was applied to the quadriceps muscle of both lower limbs of the TLG subjects immediately after the end of each training session. Using an infrared laser device (808 nm) with six diodes of 60 mW each a total energy of 50.4 J of LLLT was administered over 140 s. Muscle strength was assessed using the 1RM leg-press test and the isokinetic dynamometer test. The muscle volume of the thigh of the dominant limb was assessed by thigh perimetry. The TLG subjects showed an increase of 55% in the 1RM leg-press test, which was significantly higher than the increases in the TG subjects (26%, P = 0.033) and in the CG subjects (0.27%, P < 0.001). The TLG was the only group to show an increase in muscle performance in the isokinetic dynamometry test compared with baseline. The increases in thigh perimeter in the TLG subjects and TG subjects were not significantly different (4.52% and 2.75%, respectively; P = 0.775). Strength training associated with LLLT can increase muscle performance compared with strength training only.
Resumo:
Background: A limited number of mutations in the GH secretagogue receptor gene (GHSR) have been described in patients with short stature. Objective: To analyze GHSR in idiopathic short stature (ISS) children including a subgroup of constitutional delay of growth and puberty (CDGP) patients. Subjects and methods: The GHSR coding region was directly sequenced in 96 independent patients with ISS, 31 of them with CDGP, in 150 adults, and in 197 children with normal stature. The pharmacological consequences of GHSR non-synonymous variations were established using in vitro cell-based assays. Results: Five different heterozygous point variations in GHSR were identified (c.-6 G>C, c.251G>T (p.Ser84Ile), c.505G>A (p.Ala169Thr), c.545 T>C (p.Val182Ala), and c.1072G>A (p.Ala358Thr)), all in patients with CDGP. Neither these allelic variants nor any other mutations were found in 694 alleles from controls. Functional studies revealed that two of these variations (p.Ser84Ile and p. Val182Ala) result in a decrease in basal activity that was in part explained by a reduction in cell surface expression. The p.Ser84Ile mutation was also associated with a defect in ghrelin potency. These mutations were identified in two female patients with CDGP (at the age of 13 years, their height SDS were -2.4 and -2.3). Both patients had normal progression of puberty and reached normal adult height (height SDS of -0.7 and -1.4) without treatment. Conclusion: This is the first report of GHSR mutations in patients with CDGP. Our data raise the intriguing possibility that abnormalities in ghrelin receptor function may influence the phenotype of individuals with CDGP.
Resumo:
Background: GH insensitivity (GHI) syndrome caused by STAT5B mutations was recently reported, and it is characterized by extreme short stature and immune dysfunction. Treatment with recombinant human IGF1 (rhIGF1) is approved for patients with GHI, but the growth response to this therapy in patients with STAT5B mutations has not been reported. Objectives: To report the clinical features, molecular findings, and the short-term growth response to rhIGF1 therapy in patients with STAT5B mutation. Subjects and methods: Hormonal and immunological evaluations were performed in two male siblings with GHI associated with atopic eczema, interstitial lung disease, and thrombocytopenic purpura. STAT5B genes were directly sequenced. The younger sibling was treated with rhIGF1 at a dose of 110 mu g/kg BID. Results: Both siblings had laboratory findings compatible with GHI associated with hyperprolactinemia. Lymphopenia and reduced number of natural killer cells without immunoglobulin abnormalities were observed. STAT5B sequence revealed a homozygous frameshift mutation (p.L142fsX161) in both siblings. The younger sibling (9.9 years of age) was treated with rhIGF1 at appropriate dosage, and he did not present any significant change in his growth velocity (from 2.3 to 3.0 cm/year after 1.5 years of therapy). The presence of a chronic illness could possibly be responsible for the poor result of rhIGF1 treatment. Further studies in patients with STAT5B defects are necessary to define the response to rhIGF1 treatment in this disorder. Conclusion: GHI associated with immune dysfunction, especially interstitial lung disease, and hyperprolactinemia is strongly suggestive of a mutation in STAT5B in both sexes.
Resumo:
Peripheral nerves are structures that, when damaged, can result in significant motor and sensory disabilities. Several studies have used therapeutic resources with the aim of promoting early nerve regeneration, such as the use of low-power laser. However, this laser therapy does not represent a consensus regarding the methodology, thus yielding controversial conclusions. The objective of our study was to investigate, by functional evaluation, the comparative effects of low-power laser (660 nm and 830 nm) on sciatic nerve regeneration following crushing injuries. Twenty-seven Wistar rats subjected to sciatic nerve injury were divided into three groups: group sham, consisting of rats undergoing simulated irradiation; a group consisting of rats subjected to gallium-aluminum-arsenide (GaAlAs) laser at 660 nm (10 J/cm(2), 30 mW and 0.06 cm(2) beam), and another one consisting of rats subjected to GaAlAs laser at 830 nm (10 J/cm(2), 30 mW and 0.116 cm(2)). Laser was applied to the lesion for 21 days. A sciatic functional index (SFI) was used for functional evaluation prior to surgery and on days 7, 14, and 21 after surgery. Differences in SFI were found between group 660 nm and the other ones at the 14th day. One can observe that laser application at 660 nm with the parameters and methods utilised was effective in promoting early functional recovery, as indicated by the SFI, over the period evaluated.