224 resultados para engineered safety systems
Resumo:
Objective: To compare the performance of patients with obsessive-compulsive disorder (OCD) refractory to conventional treatments to healthy controls according to the Frontal Systems Behaviour Scale (FrSBe), comparing the scale scores within each group (Self or Family) and correlating FrSBe with Y-BOCS, DY-BOCS, tic disorder and age of first symptoms. Method: Twenty OCD patients and 20 healthy controls were assessed using the FrSBe, a scale designed to evaluate frontal syndromes. Results: The patients had higher scores when compared with the control group (p value .001) in terms of total score on the scale for both profile forms (Self and Family). In addition, there was a significant difference between the scores reported by the patients and their respective relatives. However, no correlation was observed between the scale and the other variables. Conclusions: The scale was able to clearly differentiate patients with OCD from healthy controls. This finding suggests that the FrSBe can be used not only in neurologic patients but also in psychiatric cases such as refractory OCD.
Resumo:
Objective: The aim was to compare there ulcer classification systems as predictors of the outcome of diabetic foot ulcers; the Wagner, the University of Texas (UT) and the size (area, depth), sepsis, arteriopathy, denervation system (S(AD)SAD) systems in specialist clinic in Brazil. Methods: Ulcer area, depth, appearance, infection and associated ischaemia and neuropathy were recorded in a consecutive series of 94 subjects. A novel score, the S(AD)SAD score, was derived from the sum of individual items of the S(AD)SAD system, and was evaluated. Follow-up was for at least 6 months. The primary outcome measure was the incidence of healing. Results: Mean age was 57.6 years; 57 (60.6%) were made. Forty-eight ulcers (51.1%) healed without surgery; 11 (12.2%) subjects underwent minor amputation. Significant differences in terms of healing were observed for depth (P = 0.002), infection (P = 0.006) and denervation (P = 0.002) using the S(AD)SAD system, for UT grade (P = 0.002) and stage (P = 0.032) and for Wagner grades (P = 0.002). Ulcers with an S(AD)SAD score of <= 9 (total possible 15) were 7.6 times more likely to heal than scores >= 10 (P < 0.001). Conclusions: All three systems predicted ulcer outcome. The S(AD)SAD score of ulcer severity could represent a useful addition to routine clinical practice. The association between outcome and ulcer depth confirms earlier reports. The association with infection was stronger than that reported from the centres in Europe or North America. The very strong association with neuropathy has only previously been observed in Tanzania. Studies designed to compare the outcome in different countries should adopt systems of classification, which are valid for the populations studied.
Resumo:
Introduction: Pediatric percutaneous renal biopsy (Bx) is a routine procedure in pediatric nephrology to obtain renal tissues for histological study. We evaluated the safety, efficacy, indications and renal findings of this procedure at a tertiary care pediatric university hospital and compared our findings with the literature. Methods: Retrospective study based on medical records from January 1993 to June 2006. Results: In the study period, 305 Bx were performed in 262 patients, 127 (48.5%) male, aged 9.8 +/- 4.2 years. A 16-gauge needle was utilized in 56/305 Bx, an 18-gauge needle in 252/305 Bx (82.6%). 56.1% Bx were performed under sedation plus local anesthesia, 43.9% under general anesthesia. The number of punctures per Bx was 3.1 +/- 1.3. Minor complications occurred in 8.6% procedures. The 16-gauge needle caused a higher frequency of renal hematomas (p = 0.05). The number of glomeruli per puncture was >= 5 in 96.7% and >= 7 in 92%. Glomeruli number per puncture and frequency of complications were not different according to the type of anesthesia used. A renal pathology diagnosis was achieved in 93.1% Bx. The main indications of Bx were nephrotic syndrome (NS), lupus nephritis (LN) and hematuria (HE). The diagnosis of minimal change disease (MCD) (61.3%), class V (35.6%) and IgA nephropathy (26.3%) predominated in NS, LN and HE patients, respectively. Conclusion: Pediatric real-time ultrasound-guided percutaneous renal biopsy was safe and effective. The main clinical indications for Bx were NS and LN, the predominant renal pathology diagnoses were MCD and class V LN.
Resumo:
Objective: To increase dobutamine stress echocardiography feasibility in patients with uncontrolled hypertension, we studied 729 consecutive patients referred for ischemia assessment. Methods: Patients with blood pressure ( BP) levels above 160/ 110 mm Hg were randomized to sublingual placebo or captopril ( 25 mg), and dobutamine stress echocardiography undertaken if BP decreased below 160/ 110 mm Hg after 15 minutes. Results: Of 149 patients ( 20%) with high BP levels, 104 ( 63 +/- 11 years, 51 male) were randomized. Baseline BP levels were similar for captopril ( 178 +/- 15/ 103 +/- 15 mm Hg) and placebo ( 181 +/- 17/ 103 +/- 15 mm Hg) groups. After intervention, 15 patients from captopril and 17 from placebo group had decreased BP ( 11% and 12% for systolic and 13% and 13% for diastolic BP, respectively). Five patients from placebo group ( P =.007) had to prematurely terminate the test because of hypertension ( BP > 220/ 120 mm Hg). Feasibility was similar for captopril and placebo groups ( 35% vs 25%, respectively, P = not significant). Conclusion: Although both captopril and placebo are effective in increasing dobutamine stress echocardiography feasibility in patients with uncontrolled BP, test interruption because of hypertension is less likely to occur after captopril administration.
Resumo:
Background: A 150 cm(3) pear-shaped gastric balloon with a 30 cm-long duodenal stem and a 7 g metallic weight at its distal end was designed and developed to facilitate weight loss by (a) delaying gastric emptying thus enhancing interprandial satiety, and (b) stimulating antral and duodenal receptors of satiation. Methods: Twenty-six patients (body mass index of 29 to 40 kg/m(2)) who failed to lose weight despite dietary intervention underwent endoscopic implantation of the balloon device. Patients were monitored for tolerance to the balloon, complications, weight loss, and compliance with a restricted caloric intake. Results: Six men and 20 women with a median body weight of 93.0kg (range, 73.5 to 119.9), median body mass index 34.3 kg/m(2) (range, 28.8 to 39.5) underwent balloon implantation for a median period of 4.0 months (range, 0.75 to 6.0). Twenty-two patients successfully complied with a 1250 to 1500 kcal daily diet restriction during the study period. Median weight reduction was 6.5 kg (range, 3.7 to 19.9). Patients with initial body weight of > 90 kg tended to loose more weight (8.1 kg) than patients weighing < 90 kg (4.5 kg) (P = 0.14). Nine patients with dwell times of 6 months lost 11.5 +/- 4.6 kg. The balloon malfunctioned in 4 patients (in I patient, the balloon leaked spontaneously but remained in the stomach and in 3 patients, the balloon migrated distally). Conclusions: Our novel balloon device may be effective in inducing weight loss by promoting compliance with a restricted caloric intake and is well tolerated due to its small size. Complications resulted from balloon rupture, which can be easily prevented by enhancements in design and use of alternative materials.
Resumo:
Pectus excavatum is a congenital deformity that can require surgical treatment. Since Nuss proposed a correction technique, several modifications have been proposed in order to achieve more safety and efficiency in the placement and removal of both bars. Our objective is to describe the technique of placing and removing the bars by proposing three technical modifications: two in bar placement and one in the bar removal. We describe two cases where Nuss bars were placed and one case where the bar was removed as per the technical modification proposed herein. According to the original technique, bar stabilisers. were placed close to the lateral bar edges. We propose a more medial position in order to reduce bar displacement. New stabilisers were designed with central grooves in the posterior surface, which allow better sliding. The technical modification suitable for bar removal was the use of a protective film around the bars to protect the surrounding tissues from the sharp edges, and thereby minimise the risk of injuries. All the proposed modifications were performed without any additional surgical risk or perioperative complication. These three technical modifications can be easily and safety performed, and seem to reduce the risk of bleeding with no additional perioperative complications. (C) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Resumo:
Objective: To introduce a new coupling system between screw driver and interference screw, and biomechanical tests that validate the safety of its application. Methods: The new system was submitted to biomechanical torsion assays. Two types of analysis were performed: maximum torque of manual insertion of the screws into bovine bone; destructive assays of torsion of the system using an INSTRON 55MT machine. The same tests were also performed on a control group, using a commercially available interference screw coupling system (Acufex (R)). Results: In the tests on manual insertion of screws in bovine femurs, the average values found with a digital torque meter were 1.958 N/m for Acufex (R) and 2.563 N/m for FMRP. Considering p>0.05, there were no statistical differences between the two groups (p=0.02) in the values for maximum torque of insertion, in the two systems studied. The average values for maximum torque of torsion resisted by the screw were 15N/m for the Acufex (R) screw and 13N/m for the FMRP screw, again with no statistical differences between the two groups (p>0.05). In the evaluation of angular deformation, there was also no significant difference between the two screw types (p=0.15). Conclusion: The new coupling system for interference screws developed at FMRP-USP revealed a torsion resistance that is comparable with the system already available on the market and regulated for international use.
Resumo:
In this work, we take advantage of association rule mining to support two types of medical systems: the Content-based Image Retrieval (CBIR) systems and the Computer-Aided Diagnosis (CAD) systems. For content-based retrieval, association rules are employed to reduce the dimensionality of the feature vectors that represent the images and to improve the precision of the similarity queries. We refer to the association rule-based method to improve CBIR systems proposed here as Feature selection through Association Rules (FAR). To improve CAD systems, we propose the Image Diagnosis Enhancement through Association rules (IDEA) method. Association rules are employed to suggest a second opinion to the radiologist or a preliminary diagnosis of a new image. A second opinion automatically obtained can either accelerate the process of diagnosing or to strengthen a hypothesis, increasing the probability of a prescribed treatment be successful. Two new algorithms are proposed to support the IDEA method: to pre-process low-level features and to propose a preliminary diagnosis based on association rules. We performed several experiments to validate the proposed methods. The results indicate that association rules can be successfully applied to improve CBIR and CAD systems, empowering the arsenal of techniques to support medical image analysis in medical systems. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Background: The effects of etonogestrel (ETG)-releasing contraceptive implant during the immediate postpartum period on maternal safety are unknown. Study design: Forty healthy women exclusively breastfeeding were randomized to receive either ETG-releasing implant 24-48 h after delivery (n=20) or depot medroxyprogesterone acetate (DMPA group; n=20) at the sixth week postpartum. We measured blood pressure, maternal and neonatal weight, body mass index (BMI; kg/m(2)), waist circumference (WC), complete blood count, C-reactive protein, interleukin-6, tumor necrosis factor (TNF-alpha), lipid profile, fasting serum glucose and maintenance of exclusive lactation up to the 12th week postpartum. Results: Decreases in mean maternal weight, BMI (kg/m(2)) and WC were significantly greater in the ETG-releasing implant group than in the MPA group during the first 6 weeks postpartum (-4.64 +/- 2.71 kg vs. -2.6 +/- 2.45 kg mean +/- SD, p=.017; -1.77 +/- 1.06 kg/m(2) vs. -0.97 +/- 0.95 kg/m(2), p=.026; -15.3 +/- 6.72 cm vs. -9.05 +/- 5.84 cm, p=.003, respectively). In addition, total cholesterol and HDL, were lower in DMPA users, and TNF-alpha and leukocytes were higher in DMPA users compared to in the implant group, between 6 and 12 weeks after delivery. The newborns of implant users showed a trend towards gaining more weight, as compared with the infants of the DMPA mothers during the first 6 weeks of life (implant group: +1460.50 +/- 621.34 g vs. DMPA group: +1035.0 +/- 562.43 g, p=.05). The remaining variables, including the duration of exclusive breastfeeding, were similar between the groups. Conclusion: The insertion of ETG-releasing contraceptive implant during the immediate postpartum period was not associated with deleterious maternal clinical effects or with significant maternal metabolic alterations or decreased infant weight gain. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Objective. To evaluate the safety and immunogenicity of varicella vaccine (VV) in susceptible patients with juvenile rheumatic diseases receiving methotrexate and corticosteroids. Methods. Twenty-five patients with juvenile rheumatic diseases (ages 2-19 years) and 18 healthy children and adolescents (ages 3-18 years) received a single dose of VV. All 25 patients were receiving methotrexate; 13 were also receiving prednisone and 5 were also receiving other disease-modifying antirheumatic drugs. None of the vaccinated patients or controls had a previous history of varicella. Anti-varicella-zoster virus IgG antibody (anti-VZV-IgG) titers were measured by enzyme-linked immunosorbent assay immediately before, 4-6 weeks after, and 1 year after vaccination. The patients were monitored prospectively for adverse reactions related to the vaccine, exposure, and occurrence of varicella. Disease activity was assessed 3 months before and 3 months after VV. Results. Twenty patients and all of the controls had negative preimmunization titers of VZV-IgG, and 5 patients had equivocal levels. Positive VZV-IgG titers were detected in 10 (50%) of 20 seronegative patients and 13 (72.2%) of 18 controls 4-6 weeks after VV (P = 0.2). One year after vaccination, 8 of 10 patients maintained positive VZV-IgG titers. No overt varicella episodes and no severe adverse reactions were observed during the followup period. No worsening of clinical parameters and no flares of juvenile rheumatic diseases or changes in doses of medications used were detected after vaccination. In fact, the number of active joints in patients with juvenile idiopathic arthritis was significantly lower after VV (P = 0.009). Conclusion. VV appears to be safe in patients with juvenile rheumatic diseases receiving methotrexate, as long as continuous prospective vigilance for side effects is performed.
Resumo:
Background-Puncture of the atrial appendage may provide access to the pericardial space. The aim of this study was to evaluate the feasibility of epicardial mapping and ablation through an endocardial transatrial access in a swine model. Methods and Results-An 8-F Mullins sheath was used to perforate the right (n=16) or left (n=1) atrial appendage in 17 pigs (median weight, 27.5 kg; first and third quartiles [Q1, Q3], 25.2, 30.0 kg). A 7-F ablation catheter was introduced into the pericardial space to perform epicardial mapping and deliver radiofrequency pulses on the atria. The pericardial space was entered in all 17 animals. In 15 (88%) animals, there was no hemodynamic instability (mean blood pressure monitoring, initial median, 80 mm Hg; Q1, Q3, 70, 86 mm Hg; final median, 88 mm Hg; Q1, Q3, 80, 96 mm Hg; P=0.426). In these 15, a mild hemorrhagic pericardial effusion was identified and aspirated (median, 20 mL; Q1, Q3, 15, 30 mL) during the procedure, and postmortem gross analysis revealed that the atrial perforation was closed in these animals. In 2 (12%) of the 17 animals, there was major pericardial bleeding with hemodynamic collapse. On gross examination, it was found that pericardial space was accessed through right ventricular perforation in 1 animal and the tricuspid annulus in the other. After the initial study, we used an occlusion device in 3 other animals to attempt to seal the puncture (2 at the right atrial appendage and 1 at the right ventricle). These 3 animals had no significant pericardial bleeding. Conclusions-Transatrial endovascular right atrial appendage puncture may provide a potential alternative route for pericardial access. Further studies are needed to evaluate its safety with longer and more-complex procedures before being applied in clinical settings. (Circ Arrhythm Electrophysiol. 2011;4:331-336.)
Resumo:
Background Reports of iatrogenic thermal injuries during laparoscopic surgery using new generation vessel-sealing devices, as well as anecdotal reports of hand burn injuries during hand-assisted surgeries, have evoked questions about the temperature safety profile and the cooling properties of these instruments. Methods This study involved video recording of temperatures generated by different instruments (Harmonic ACE [ACE], Ligasure V [LV], and plasma trisector [PT]) applied according the manufacturers` pre-set settings (ACE setting 3; LV 3 bars, and the PT TR2 50W). The video camera used was the infrared Flex Cam Pro directed to three different types of swine tissue: (1) peritoneum (P), (2) mesenteric vessels (MV), and (3) liver (L). Activation and cooling temperature and time were measured for each instrument. Results The ACE device produced the highest temperatures (195.9 degrees +/- 14.5 degrees C) when applied against the peritoneum, and they were significantly higher than the other instruments (LV = 96.4 degrees +/- 4.1 degrees C, and PT = 87 degrees +/- 2.2 degrees C). The LV and PT consistently yielded temperatures that were < 100 degrees C independent of type of tissue or ""on""/ ""off"" mode. Conversely, the ACE reached temperatures higher than 200 degrees C, with a surprising surge after the instrument was deactivated. Moreover, temperatures were lower when the ACE was applied against thicker tissue (liver). The LV and PT cooling times were virtually equivalent, but the ACE required almost twice as long to cool. Conclusions The ACE increased the peak temperature after deactivation when applied against thick tissue (liver), and the other instruments inconsistently increased peak temperatures after they were turned off, requiring few seconds to cool down. Moreover, the ACE generated very high temperatures (234.5 degrees C) that could harm adjacent tissue or the surgeon`s hand on contact immediately after deactivation. With judicious use, burn injury from these instruments can be prevented during laparoscopic procedures. Because of the high temperatures generated by the ACE device, particular care should be taken when it is used during laparoscopy.
Resumo:
Contents The aim of this research was to evaluate the efficacy of zinc gluconate associated with dimethyl sulphoxide (DMSO) for chemical neutering in canine males. Fifteen sexually mature male dogs were divided in two groups, named control and treated. An injection was administered to both testicles, at a concentration of 26.2 mg zinc gluconate per ml and 0.5% DMSO in the treated group (11 dogs). The control group was given injections of saline solution (four dogs). Clinical examination and blood collection for a haemogram were done both before and after drug injection. There were 12 spermograms performed to analyse sperm motility, sperm vigour, ejaculate volume, testicle size, pathology and sperm concentrations. Libido was also measured. An ultrasound examination and histopathology were performed at the end of the experiment. Dogs` libido after chemical injection was reduced by over 50%. The spermogram analysis showed final mean results of 14.54% for sperm motility, 0.72 of sperm vigour and 37 150 per million spermatozoa per millilitre, values considered below the necessary levels at which fertilization can occur. Ultrasound and histopathology analyses of testicles for the treated group revealed more intense injuries when compared with the control group, with compromised testicular parenchyma and a decrease of germ cell number leading to total atrophy, indicating that the treatment reduced the fertilizing potential of male dogs, promoting a possible subfertile status.