385 resultados para Immunologic Tests -- methods


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this article is to examine the causality between government size and corruption, and to verify if there is a different pattern of causality between developed Organization for Economic Co-operation and Development (OECD) countries (excluding Mexico) and developing countries (Latin American countries) during the period 1996 to 2003. Applying Granger and Huang`s (1997) methodology we find evidence that size of government Granger causes corruption in both samples. Since a larger government involvement in private markets today will be followed in future by a higher level of corruption a policy advice would be to enhance governance. The promotion of good governance helps to combat corruption given that it complements efforts to reduce corruption more directly, and it is strongly recommended by the International Monetary Fund, other multilateral institutions, and all worried with the negative impacts of corruption on economic activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper uses a unique new data set on manufacturing firms in Brazil and India to estimate production functions, augmented by information and communications technology (ICT). We find a strong positive association between ICT capital and productivity in both countries that is robust to several different specification tests. The paper also breaks new ground when using the Indian data to investigate the effect of the institutional and policy environment on ICT capital investment and productivity. We find that poorer infrastructure quality and labor market policy are associated with lower levels of ICT adoption, while poorer infrastructure is also associated with lower returns to investment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper examines the hysteresis hypothesis in the Brazilian industrialized exports using a time series analysis. This hypothesis finds an empirical representation into the nonlinear adjustments of the exported quantity to relative price changes. Thus, the threshold cointegration analysis proposed by Balke and Fomby [Balke, N.S. and Fomby, T.B. Threshold Cointegration. International Economic Review, 1997; 38; 627-645.] was used for estimating models with asymmetric adjustment of the error correction term. Amongst sixteen industrial sectors selected, there was evidence of nonlinearities in the residuals of long-run relationships of supply or demand for exports in nine of them. These nonlinearities represent asymmetric and/or discontinuous responses of exports to different representative measures of real exchange rates, in addition to other components of long-run demand or supply equations. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Understanding the excretion of 3,4-methylenedioxymethamphetamine (MDMA) and metabolites in sweat is vital for interpretation of sweat tests in drug treatment, criminal justice, and workplace programs. METHODS: Placebo, low (1.0 mg/kg), and high (1.6 mg/kg) doses of oral MDMA were given double-blind in random order to healthy volunteers (n = 15) with histories of MDMA use. Participants resided on the closed clinical research unit for up to 7 days after each dose. Volunteers wore PharmChek (R) sweat patches (n = 640) before, during, and after controlled dosing. Patches were analyzed by solid phase extraction and GC-MS for MDMA, methylenedioxyamphetamine (MDA), 4-hydroxy-3-methoxyamphetamine (HMA), and 4hydroxy-3-methoxymethamphetamine (HMMA). Limits of quantification (LOQ) were 2.5 ng/patch for MDMA and 5 ng/patch for HMA, HMMA, and MDA. RESULTS: MDMA was the primary analyte detected in 382 patches (59.7%), with concentrations up to 3007 ng/patch. MDA was detected in 188 patches (29.4%) at <172 ng/patch, whereas no HMMA or HMA was detected; 224 patches (35.0%) and 60 patches (9.4%) were positive for MDMA and MDA, respectively, at the 25-ng/patch threshold proposed by the Substance Abuse and Mental Health Services Administration. CONCLUSIONS: Sweat testing was shown to be an effective and reliable method for monitoring MDMA use in this controlled MDMA administration study. However, variability in sweat excretion suggests that results should be interpreted qualitatively rather than quantitatively. These data provide a scientific database for interpretation of MDMA sweat test results. (C) 2008 American Association for Clinical Chemistry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preparation methods can profoundly affect the structural and electrochemical properties of electrocatalytic coatings. In this investigation, RuO(2)-Ta(2)O(5) thin films containing between 10 and 90 at.% Ru were prepared by the Pechini-Adams method. These coatings were electrochemically and physically characterized by cyclic voltammetry, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD). The composition and morphology of the oxide were investigated before and after accelerated life tests (ALT) by EDX and SEM. SEM results indicate typical mud-flat-cracking morphology for the majority of the films. High resolution SEMs reveal that pure oxide phases exhibit nanoporosity while binary compositions display a very compact structure. EDX analyses reveal considerable amounts of Ru in the coating even after total deactivation. XRD indicated a rutile-type structure for RuO(2) and orthorhombic structure for Ta(2)O(5). XPS data demonstrate that the binding energy of Ta is affected by Ru addition in the thin films, but the binding energy of Ru is not likewise influenced by Ta. The stability of the electrodes was evaluated by ALT performed at 750 mA cm(-2) in 80 degrees C 0.5 mol dm(-3) H(2)SO(4). The performance of electrodes prepared by the Pechini-Adams method is 100% better than that of electrodes prepared by standard thermal decomposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analytical and bioanalytical methods of high-performance liquid chromatography with fluorescence detection (HPLC-FLD) were developed and validated for the determination of chloroaluminum phthalocyanine in different formulations of polymeric nanocapsules, plasma and livers of mice. Plasma and homogenized liver samples were extracted with ethyl acetate, and zinc phthalocyanine was used as internal standard. The results indicated that the methods were linear and selective for all matrices studied. Analysis of accuracy and precision showed adequate values, with variations lower than 10% in biological samples and lower than 2% in analytical samples. The recoveries were as high as 96% and 99% in the plasma and livers, respectively. The quantification limit of the analytical method was 1.12 ng/ml, and the limits of quantification of the bioanalytical method were 15 ng/ml and 75 ng/g for plasma and liver samples, respectively. The bioanalytical method developed was sensitive in the ranges of 15-100 ng/ml in plasma and 75-500 ng/g in liver samples and was applied to studies of biodistribution and pharmacokinetics of AlClPc. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The image reconstruction using the EIT (Electrical Impedance Tomography) technique is a nonlinear and ill-posed inverse problem which demands a powerful direct or iterative method. A typical approach for solving the problem is to minimize an error functional using an iterative method. In this case, an initial solution close enough to the global minimum is mandatory to ensure the convergence to the correct minimum in an appropriate time interval. The aim of this paper is to present a new, simple and low cost technique (quadrant-searching) to reduce the search space and consequently to obtain an initial solution of the inverse problem of EIT. This technique calculates the error functional for four different contrast distributions placing a large prospective inclusion in the four quadrants of the domain. Comparing the four values of the error functional it is possible to get conclusions about the internal electric contrast. For this purpose, initially we performed tests to assess the accuracy of the BEM (Boundary Element Method) when applied to the direct problem of the EIT and to verify the behavior of error functional surface in the search space. Finally, numerical tests have been performed to verify the new technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Hypertrophic cardiomyopathy (HCM) is associated with arrhythmias and cardiovascular death. Left atrial enlargement and atrial fibrillation (AF) are considered markers for death due to heart failure in patients with HCM. Obstructive sleep apnea (OSA) is independently associated with heart remodeling and arrhythmias in other populations. We hypothesized that OSA is common and is associated with heart remodeling and AF in patients with HCM. Methods: We evaluated 80 consecutive stable patients with a confirmed diagnosis of HCM by sleep questionnaire, blood tests, echocardiography, and sleep study (overnight respiratory monitoring). Results: OSA (apnea-hypopnea index [AHI] > 15 events/h) was present in 32 patients (40%). Patients with OSA were significantly older (56 [41-64] vs 38.5 [30-53] years, P < .001) and presented higher BMI (28.2 +/- 3.5 vs 25.2 +/- 5.2 kg/m(2), P < .01) and increased left atrial diameter (45 [42-52.8] vs 41 [39-47] mm, P = .01) and aorta diameter (34 [30-37] vs 29 [28-32] mm, P < .001), compared with patients without OSA. Stepwise multiple linear regression showed that the AHI (P = .05) and BMI (P = .06) were associated with left atrial diameter. The AHI was the only variable associated with aorta diameter (P = .01). AF was present in 31% vs 6% of patients with and without OSA, respectively (P < .01). OSA (P = .03) and left atrial diameter (P = .03) were the only factors independently associated with AF. Conclusions: OSA is highly prevalent in patients with HCM and it is associated with left atrial and aortic enlargement. OSA is independently associated with AF, a risk factor for cardiovascular death in this population. CHEST 2010; 137(5):1078-1084

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The Helicobacter pylori reinfection seems to be higher in developing countries, than in developed ones. The aim of the study was to determine the annual recurrence rate of H. pylori, in Brazilian patients with peptic ulcer disease, in a 5-year follow-up. Methods: Patients, with peptic ulcer disease diagnosed by upper digestive endoscopy (UDE) and H. pylori infection verified by histological analysis, rapid urease test, polymerase chain reaction, and urea breath test (UBT), were treated for bacterial eradication. The cure of the infection was verified using the same tests, 3 months after. Clinical evaluation and UBT were performed after sixth and ninth month. After 1 year of follow-up, UBT and UDE were repeated. Up to the fifth year, patients were assessed twice a year and an UBT was performed annually. The patients included and all the reinfected were tested for 15 different genes of the H. pylori. Results: One hundred and forty-seven patients were followed: 19 for 1 year, eight for 2 years, four for 3 years, five for 4 years, and 98 for 5 years, totaling 557 patients/years. Recurrence did not occur in the first year. In the second year, two patients were reinfected; in the third, four patients; in the fourth, three patients; and in the fifth, one patient. The total of reinfected patients was 10. The annual reinfection rate was 1.8%. Conclusion: Brazil presents a low prevalence of H. pylori reinfection, similar to the developed countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To study the oculometric parameters of hyperopia in children with esotropic amblyopia, comparing amblyopic eyes with fellow eyes. Methods: Thirty-seven patients (5-8 years old) with bilateral hyperopia and esotropic amblyopia underwent a comprehensive ophthalmic examination, including cycloplegic refraction, keratometry and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. The refractive power of the crystalline lens was calculated using Bennett`s equations. Paired Student`s t-tests were used to compare ocular biometric measurements between amblyopic eyes and their fellow eyes. The associations of biometric parameters with refractive errors were assessed using Pearson correlation coefficients and linear regression. Multivariable models including axial length, corneal power and lens power were also constructed. Results: Amblyopic eyes were found to have significantly more hyperopic refraction, less corneal power, greater lens power, shorter vitreous chamber depth and shorter axial length, despite similar anterior chamber depth and lens thickness. The strongest correlation with refractive error was observed for the axial length/corneal radius ratio (r(36) = -0.92, p < 0.001 for amblyopic and r(36) = 0.87, p < 0.001 for fellow eyes). Axial length accounted for 39.2% (R(2)) of the refractive error variance in amblyopic eyes and 35.5% in fellow eyes. Adding corneal power to the model increased R(2) to 85.7% and 79.6%, respectively. A statistically significant correlation was found between axial length and corneal power, indicating decreasing corneal power with increasing axial length, and they were similar for amblyopic eyes (r(36) = 0.53,p < 0.001) and fellow eyes (r(36) = -0.57, p < 0.001). A statistically significant correlation was also found between axial length and lens power, indicating decreasing lens power with increasing axial length (r(36) = -0.72, p < 0.001 for amblyopic eyes and r(36) = -0.69, p < 0.001 for fellow eyes). Conclusions: We observed that the correlation among the major oculometric parameters and their individual contribution to hyperopia in esotropic children were similar in amblyopic and non-amblyopic eyes. This finding suggests that the counterbalancing effect of greater corneal and lens power associated with shorter axial length is similar in both eyes of patients with esotropic amblyopia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Phrenic nerve transfer has been used for treating lesions of the brachial plexus since 1970. Although, today, surgeons are more experienced with the technique, there are still widespread concerns about its effects on pulmonary function. This study was undertaken to evaluate the effectiveness and safety of this procedure. METHODS: Fourteen patients with complete palsy of the upper limb were submitted to phrenic nerve transfer as part of a strategy for surgical reconstruction of their plexuses. Two patients were lost to follow-up, and 2 patients were followed for less than 2 years. Of the remaining 10 patients, 9 (90%) were male. The lesions affected both sides equally. The mean age of the patients was 24.8 years (range, 14-43 years), and the mean interval from injury to surgery was 6 months (range, 3-9 months). The phrenic nerve was always transferred to the musculocutaneous nerve, and a nerve graft (mean length, 8 cm; range, 4.5-12 cm) was necessary in all cases. RESULTS: There was no major complication related to the surgery. Seven patients (70%) recovered functional level biceps strength (Medical Research Council grade >= 3). All of the patients exhibited a transient decrease in pulmonary function tests, but without clinical respiratory problems. CONCLUSION: On the basis of our small series and data from the literature, we conclude that phrenic nerve transfer in well-selected patients is a safe and effective procedure for recovering biceps function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Many methods exist in the literature for identifying PEEP to set in ARDS patients following a lung recruitment maneuver (RM). We compared ten published parameters for setting PEEP following a RM. Methods: Lung injury was induced by bilateral lung lavage in 14 female Dorset sheep, yielding a PaO(2) 100-150 mmHg at F(I)O(2) 1.0 and PEEP 5 cmH(2)O. A quasi-static P-V curve was then performed using the supersyringe method; PEEP was set to 20 cmH(2)O and a RM performed with pressure control ventilation (inspiratory pressure set to 40-50 cmH(2)O), until PaO(2) + PaCO(2) > 400 mmHg. Following the RM, a decremental PEEP trial was performed. The PEEP was decreased in 1 cmH(2)O steps every 5 min until 15 cmH(2)O was reached. Parameters measured during the decremental PEEP trial were compared with parameters obtained from the P-V curve. Results: For setting PEEP, maximum dynamic tidal respiratory compliance, maximum PaO(2), maximum PaO(2) + PaCO(2), and minimum shunt calculated during the decremental PEEP trial, and the lower Pflex and point of maximal compliance increase on the inflation limb of the P-V curve (Pmci,i) were statistically indistinguishable. The PEEP value obtained using the deflation upper Pflex and the point of maximal compliance decrease on the deflation limb were significantly higher, and the true inflection point on the inflation limb and minimum PaCO(2) were significantly lower than the other variables. Conclusion: In this animal model of ARDS, dynamic tidal respiratory compliance, maximum PaO(2), maximum PaO(2) + PaCO(2), minimum shunt, inflation lower Pflex and Pmci,i yield similar values for PEEP following a recruitment maneuver.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective ""CORE-64"" trial (""Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors""). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Current relevance of T-wave alternans is based on its association with electrical disorder and elevated cardiac risk. Quantitative reports would improve understanding on TWA augmentation mechanisms during mental stress or prior to tachyarrhythmias. However, little information is available about quantitative TWA values in clinical populations. This study aims to create and compare TWA profiles of healthy subjects and ICD patients, evaluated on treadmill stress protocols. Methods: Apparently healthy subjects, not in use of any medication were recruited. All eligible ICD patients were capable of performing an attenuated stress test. TWA analysis was performed during a 15-lead treadmill test. The derived comparative profile consisted of TWA amplitude and its associated heart rate, at rest (baseline) and at peak TWA value. Chi-square or Mann-Whitney tests were used with p values <= 0.05. Discriminatory performance was evaluated by a binary logistic regression model. Results: 31 healthy subjects (8F, 23M) and 32 ICD patients (10F, 22M) were different on baseline TWA (1 +/- 2 mu V; 8 +/- 9 mu V; p < 0.001) and peak TWA values (26 +/- 13 mu V; 37 +/- 20 mu V; p = 0,009) as well as on baseline TWA heart rate (79 +/- 10 bpm; 67 +/- 15 bpm; p < 0.001) and peak TWA heart rate (118 +/- 8 bpm; 90 +/- 17 bpm; p < 0.001). The logistic model yielded sensitivity and specificity values of 88.9% and 92.9%, respectively. Conclusions: Healthy subjects and ICD patients have distinct TWA profiles. The new TWA profile representation (in amplitude-heart rate pairs) may help comparison among different research protocols. Ann Noninvasive Electrocardiol 2009;14(2):108-118.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Smell identification tests may be of routine clinical value in the differential diagnosis of PD but are subject to cultural variation and have not been systematically evaluated in the Brazilian population. We have applied culturally adapted translations of the University of Pennsylvania 40-item smell identification test (UPSIT-40) and the 16-item identification test from Sniffin` Sticks (SS-16) to nondemented Brazilian PD patients and controls. Pearson`s correlation coefficient between the test scores was 0.76 (95% CI 0.70-0.81, n = 204, P < 0.001). To calculate reliability measures for each test we used the diagnosis (either PD or control) as outcome variable for separate logistic regression analyses using the score in the UPSIT-40 or the SS-16 as a covariate. The SS-16 specificity was 89.0% with a sensitivity of 81.1% (106 PD and 118 controls). The UPSIT-40 specificity was 83.5% and its sensitivity 82.1% (95 PD and 109 controls). Regression curves were used to associate an individual`s smell test score with the probability of belonging to the PD, as opposed to the control group. Our data provide support for the use of the UPSIT-40 and SS-16 to help distinguish early PD from controls. (c) 2008 Movement Disorder Society