213 resultados para DRY EYE SYNDROME


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the orthodontic treatment of a patient with Klippel-Trenaunay-Weber syndrome (KTWS) who received orthodontic treatment that included rapid palatal expansion and orthognathic surgery. There is no report in the literature with this orthodontic treatment protocol, that was considered successful. The pros and cons of this approach as well as the risks involved are discussed. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e17-e25)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To evaluate the effects of surface moisture (wet or dry) and storage (24h or 3 months) on the microtensile bond strength (BS) of resin/dentin bonds mediated by two water/ethanol based adhesives Single Bond, 3M-ESPE, (SB) and Opti Bond Solo Plus, Kerr, (OB), and two acetone-based adhesives, One Step, Bisco, (OS) and Prime&Bond NT, Caulk/Dentsply, (PB). Materials and methods. Flat dentin surfaces were polished with 600-grit SiC paper, etched with 35% phosphoric acid for 15 s and rinsed for 20 s. Half the surface was maintained moist and the other half was air-dried for 30 s. Each adhesive was applied simultaneously to both halves, left undisturbed for 30 s and light-cured. Four-mm resin build-ups were constructed incrementally. After storage in water at 37 degrees C for 24h, slabs were produced by transversal sectioning and trimmed to an hourglass shape (0.8 mm 2). Half of the specimens were tested in tension at 0.6 mm/min immediately after trimming and the other half after 3 months of water storage. Data were analyzed by two-way ANOVA and SNK for each material. Results. Both moisture and storage affected BS to dentin, and was material- dependent. Dry, bonding affected mostly the acetone-based adhesives. Larger reductions in bond strength were associated with dry bonding after 3 months of water storage. Significance. Wet bonding resulted in more stable bonds over 3 months of water storage for most of the materials tested. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Metabolic syndrome (MetS) predisposes to cardiovascular complications. Increased concentrations of pro-inflammatory mediators and imbalanced concentrations of matrix metalloproteinases (MMPs) and their inhibitors (TIMPs) may reflect the pathophysiology of MetS. We compared the circulating levels of MMPs, TIMPs, and inflammatory mediators in MetS patients with those found in healthy controls. Methods: We studied 25 healthy subjects and 25 MetS patients. The plasma levels of pro-MMP-2 and pro-MMP-9 were determined by gelatin zymography. The plasma concentrations of MMP-8, MMP-3, TIMP-1, TIMP-2, monocyte chemoattractant protein-1 (MCP-1), interleukin-6 (IL-6), intercellular adhesion molecule (sICAM-1), and sP-selectin were measured by ELISA kits. Results: We found higher sP-selectin, sICAM-1, MCP-1, and IL-6 (all P<0.05) concentrations in MetS patients compared with healthy controls. No differences in pro-MMP-2, MMP-3, and TIMP-2 levels were found (all P>0.05). However, we found higher pro-MMP-9, MMP-8. and TIMP-1 levels in MetS patients compared with healthy controls (all P<0.05). Conclusions: Patients with MetS have increased circulating concentrations of pro-MMP-9, MMP-8, and TIMP-1 that are associated with increased concentrations of pro-inflammatory mediators and adhesion molecules. These findings suggest that MMPs may have a role in the increased cardiovascular risk of MetS patients. Pharmacological interventions targeting MMPs, especially MMP-9 and MMP-8 deserve further investigation in MetS patients. (C) 2009 Elsevier B.V. All rights reserved.