187 resultados para Acquired pellicle


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The objective of the present study was to assess the prevalence of untreated caries in a Brazilian paediatric acquired immunodeficiency syndrome (AIDS) patient population and its association with sociodemographic, behavioural and clinical characteristics. Materials and Methods: The study group was comprised of 125 HIV-infected patients (aged 3 to 15 years) who had already manifested AIDS and were assisted in a specialised health care unit. Dental examinations followed the World Health Organization`s guidelines for oral health surveys. Family caregivers provided information about the socioeconomic standing and the behaviour of their children. Patients` medical records in the hospital provided information on the clinical status of patients. A Poisson regression analysis was used for assessing the covariates for the prevalence of untreated dental caries, as adjusted by age. Results: The prevalence of untreated caries was 58%; a higher prevalence was found in younger children with primary and mixed dentition. The prevalence of untreated caries associated significantly with lower socioeconomic status (household crowding and schooling of the caregiver), dietary habits (higher frequency of sugar consumption) and poorer clinical status (HIV viral load and symptom severity). Conclusions: The high burden of untreated caries on paediatric AIDS patients reinforced the importance of integrating the clinician with the interdisciplinary health care team that assisted these children. The identification of socioeconomic and behavioural factors associated with caries experience reinforced the importance of the attention that children with AIDS received within their own households for the prevention of dental disease, particularly a proper nutritional advisement and monitoring of dental hygiene.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This in situ/ex vivo study assessed the effect of titanium tetrafluoride (TiF4) on permanent human enamel subjected to erosion. Design: Ten volunteers took part in this study performed in two phases. In the first phase (ERO), they wore acrylic palatal appliances containing two enamel blocks, divided into two rows: TiF4 (F) and no-TiF4 (no-F). During the 1st day, the formation of a salivary pellicle was allowed. In the 2nd day, the TiF4 solution was applied on one row (ERO + F), whereas on the other row no treatment was performed (ERO + no-F). From 3rd until 7th day, the blocks were subjected to erosion, 4x per day. In the 2nd phase (no-ERO), the volunteers wore acrylic palatal appliances containing one enamel block, during 2 days, to assess the effect of TiF4 only (no-ERO + F). Enamel alterations were determined using profilometry (wear), microhardness (%SMHC) tests, scanning electron microscope and microprobe analysis. The %SMHC and wear were tested using ANOVA and Tukey`s post hoc tests (p < 0.05). Results: The mean of %SMHC and wear ( mu m) values ( +/- S.D.) were, respectively: ERO + F -73.32 +/- 5.16(A)/2.40 +/- 0.60(a); ERO + no-F -83.49 +/- 4.59B/1.17 +/- 0.48(b) and no-ERO + F -67.92 +/- 6.16(A)/0.21:E 0.09(c). In microscope analysis, the no-F group showed enamel with honeycomb appearance. For F groups, it was observed a surface coating with microcracks. The microprobe analysis revealed the presence of the following elements (%) in groups ERO + F, ERO + no-F and no-ERO + F, respectively: Ca (69.9, 72.5, 66.25); P (25.9, 26.5, 26.06); Ti (3.0, 0, 5.93). Conclusions: The TiF4 was unable to reduce dental erosion. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Individuals with cariogenic diet can also consume erosive beverages. Thus, it seems necessary to investigate a possible caries/erosion interaction. To test in situ/ex vivo a combination of these challenges, 11 subjects wore intraoral appliances containing four enamel blocks randomly assigned. In the first 2-week phase, the appliances were immersed in a cola drink 3 times/day. Two blocks were free of plaque (erosion only: EO) and two blocks were covered with plaque (erosion + plaque: EP). In the second 2-week phase, four new blocks were all covered with plaque and subjected to a sucrose solution 8 times/day. Among the four new blocks, two were also subjected to the cola drink 3 times/day (erosion + caries: EC) while the other two were not (caries only: CO). Thus, in EO, the specimens were fixed at the intraoral appliance level. In EP, EC and CO they were fixed 1.0 mm under the appliance level and covered with plastic meshes for dental plaque accumulation. Changes in wear and hardness were measured. Data were tested using ANOVA and Tukey`s test (p < 0.05). Mean values of wear (mu m) and change in hardness (kp/mm(2)) were: EO 4.82/310; EP 0.14/48; EC 0.34/245; CO 0.42/309. With respect to surface softening, EP and EC differed significantly from each other and from EO and CO, which did not differ significantly. EO presented significantly higher wear than the other groups. The data suggest that the presence of dental plaque can decrease the acid attack of an erosive drink and the association of erosive and cariogenic challenges showed less enamel alterations when compared to erosive or cariogenic challenges only. Copyright (C) 2008 S. Karger AG, Basel

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The objective of the present in situ study was to evaluate the influence of dental plaque on human enamel erosion. Materials and Methods: Thirteen volunteers wore acrylic palatal devices with four enamel specimens that were prepared from freshly extracted impacted human third permanent molars (4 x 4 mm), randomly selected and distributed into two vertical rows, corresponding to the following groups: GI, erosion of dental plaque-free samples, and GII, erosion of dental plaque-covered samples. For the formation of dental plaque, the specimens were placed 1 mm below the level of the appliance and covered with a plastic mesh to allow the accumulation of dental plaque. The palatal device was continuously worn by the volunteers for 14 consecutive days and then immersed in a soft drink (Coca-Cola (R), 150 ml) for 5 min, three times a day. Half of the surfaces of specimens were coated with nail varnish for profilometry tests. The study variables included the depth of enamel surface wear (profilometer, vertical ranges in pm) and the percentage of superficial microhardness change (%SMHC). Data were analysed using the t test (P < 0.05). Results: The %SMHC and depth of enamel surface wear were significantly higher for GI (-87.82% +/- 3.66 and 4.70 mu m +/- 1.65) than for GII (-13.79% +/- 4.22 and 0.14 mu m +/- 0.03). Conclusions: It was concluded that the dental plaque formed in situ was able to protect the enamel surface against erosion by a cola soft drink, thus reducing the depth of enamel surface wear and the %SMHC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This in vitro study aimed to analyse the effect of a single application of TiF(4) and NaF varnishes and solutions to protect against dentin erosion. Methods: Bovine root dentin samples were pre-treated with NaF-Duraphat varnish (2.26%F, pH 4.5), NaF/CaF(2)-Duofluorid varnish (5.63%F, pH 8.0), NaF-experimental varnish (2.45%F, pH 4.5), TiF(4)-experimental varnish (2.45%F, pH 1.2), NaF solution (2.26%F, pH 4.5), TiF(4) solution (2.45%F, pH 1.2) and placebo varnish (pH 5.0, no-F varnish control). Controls remained untreated. Ten samples in each group were then subjected to an erosive demineralisation (Sprite Zero, 4x 90 s/day) and remineralisation (artificial saliva, between the erosive cycles) cycling for S days. Dentin loss was measured profilometrically after pretreatment and after 1, 3 and 5 days of de-remineralisation cycling. The data were statistically analysed by two-way ANOVA and Bonferroni`s post hoc test (p < 0.05). Results: After pre-treatment, TiF(4) solution significantly induced surface loss (1.08 +/- 0.53 mu m). Only Duraphat reduced the dentin loss overtime, but it did not significantly differ from placebo varnish (at 3rd and 5th days) and TiF(4) varnish (at 3rd day). Conclusions: Duraphat varnish seems to be the best option to partially reduce dentin erosion. However, the maintenance of the effects of this treatment after successive erosive challenges is limited. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess, by a crossover 2 x 2 in situ study, the speculated protective role of a sodium bicarbonate-containing toothpaste in controlling erosive lesions. Methods: Bovine enamel slabs were sterilized, and submitted to baseline Knoop microhardness measurements. After a 3-day lead-in period, 14 volunteers wore palatal acrylic appliances containing six enamel slabs (three on each side), for 4 consecutive days. On the first day, appliances with contained specimens were placed in the oral cavity to allow salivary pellicle formation. On the subsequent days, half of the enamel slabs were immersed extraorally in a lemonade-like soft drink for 90 seconds, twice daily. On both of these occasions, the appliance was dipped in toothpaste slurry of either a sodium bicarbonate-containing toothpaste or a regular counterpart for 60 seconds. Following a 3-day washout period, a new set of enamel slabs were mounted and the volunteers started the second period using the alternate dentifrice. Results: ANOVA (alpha = 0.05) showed no statistically significant difference between enamel treated with regular and sodium bicarbonate-based dentifrices, regardless of whether specimens were eroded or not (P=0.8430). Acid-challenged specimens revealed lower microhardness values than uneroded samples. (Am J Dent 2008;21:300-302).