159 resultados para Milk - Quality


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methods. aEuro integral Thirty mothers of disabled children participated in the study. The control group comprised of 18 healthy mothers of children without disabilities. All mothers agreed to participate in the study. They completed the evaluation forms of the SF-36 health survey, a well-documented, self-administered QOL scoring system. Results. aEuro integral The results of our study support the premise that mothers of children with CP, as a group, have poorer QOL than mothers of not disabled children. Conclusions. aEuro integral We also observed that mothers of children with CP and epilepsy have poorer QOL than mothers of children with CP without epilepsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present trial was to compare the percentages of necrotic and apoptotic polymorphonuclear leukocytes (PMNL) in goat milk with low and high somatic cell count (SCC). Twenty eight milk samples were collected from 20 lactating goats, determined to be negative in bacteriological examination, and divided in three groups, according to their SCC: samples with SCC lower than 500 x 10(3) cells/mL; between 500 and 1500 x 10(3) cells/mL; and higher than 1500 x 10(3) cells/m L. SCC was performed in an automatic somatic cell counter. Apoptosis and necrosis were quantified using dual-color flow cytometry with fluorescein labeled annexin-V and propidium iodide (PI). Results of the present study showed a significant positive correlation between the percentage of the viable PMNL and milk SCC(r = 0.495, P=0.008), as well as a significant negative correlation between apoptotic PMNL and milk SCC(r = -0.486, P = 0.009). Results also pointed out lower PMNL viability rates due to higher apoptosis rates in milk samples with SCC lower than 5 x 10(5) cells/mL. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to evaluate the effect of beta-lactoglobulin (beta-lg) polymorphism and seasonality on milk composition (fat, lactose, total solids, milk urea nitrogen, total protein, true protein, casein and somatic cell counts) of Holstein and Girolando cows. Milk and blood samples from 278 Holsteins cows and 156 Girolando cows were taken during two dry seasons and two rainy seasons, for milk composition analysis and to determine beta-lg genotypes, respectively. BB genotype was the most frequent for both breeds, followed by AA genotype for Holstein (BB>AA>AB) and by AB for Girolando cows (BB>AB>AA). No differences were found in milk compositional characteristics among genetic variants of beta-lg (AA, AB and BB) either between Holstein or Girolando cows. No association between milk composition and beta-lg genetic polymorphism was observed. During the dry season, independently of the breed considered, higher contents of lactose, true protein, casein and casein :true protein ratio were found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prototheca zopfii has been considered one of the most important causes of environmental mastitis in Brazil. These algae are refractory to conventional therapy and cause great damage to the mammary gland. The present study evaluated the in vitro algaecide effect of sodium hypochlorite and iodine based antiseptics on 27 P. zopfii strains isolated from the milk of cattle. Low concentrations of sodium hypochlorite (0.0390625-0.15625%) and iodine (0.15625-0.625%) were effective against the isolates. These antiseptics may be recommended for hygiene routines, pre and postdipping and cauterization of bovine mammary glands infected by P. zopfii. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were (1) to determine the sensitivity (Se) and specificity (Sp) of somatic cell count (SCC) thresholds to identify subclinical mastitis in Gyr cows caused by major and minor pathogens; (2) to study the effects of month of sampling, rear or front mammary quarters, herd, intramammary infection (IMI), and bacterial species on SCC at quarter level; and (3) to describe the prevalence of IMI in Gyr cows in commercial dairy herds. In total, 221 lactating Gyr cows from 3 commercial dairy farms were selected. Milk samples were collected from individual quarters once a month for 1 yr from all lactating cows for SCC and bacteriological analysis. Mammary quarters were considered the experimental units and the SCC results were log(10)-transformed. Four SCC thresholds (100, 200, 300 and 400 x 10(3) cells/mL) were used to determine Se and Sp to identify infected mammary quarters. The overall prevalence of IMI in quarter milk samples of Gyr cows was 49.8%, and the prevalence of minor pathogens was higher (31.9%) than that of major pathogens (17.8%). Quarter samples with microbial isolation presented higher SCC compared with negative samples. Sensitivity and Sp of selected SCC thresholds varied according to the group of pathogen (major and minor) involved in the IMI definition. Sensitivity increased and Sp decreased when mammary quarters with only major pathogens isolation were considered positive. The use of a single SCC analysis to classify quarters as uninfected or infected in Gyr cows may not be a useful test for this breed because Se and Sp of SCC at the studied thresholds were low. The occurrence of IMI and the bacterial species are the main factors responsible for SCC variation in mammary quarters of Gyr cows. Milk samples with major pathogens isolation elicited higher SCC than those with minor pathogens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Euro-Collins solution was developed for the preservation of organs for transplantation, whose characteristics have raised interest for its use as a storage medium for avulsed teeth before replantation. This study evaluated histologically and morphometrically the healing process of dog teeth replanted after storage in Euro-Collins solution or bovine milk. Materials and Methods: Eighty roots of 4 young adult mongrel clogs were randomly assigned to 4 groups (n = 20) and the root canals were instrumented and obturated with gutta-percha and a calcium hydroxide-based sealer. After 2 weeks, the teeth were extracted and subjected to the following protocols: GI (negative control), replantation immediately after extraction; GII (positive control), bench-drying for 2 hours before replantation; GIII and GIV, immersion in 10 mL of whole bovine milk and Euro-Collins solution at 4 C, respectively, for 8 hours before replantation. The animals were sacrificed 90 days postoperatively. The pieces containing the replanted teeth were subjected to routine processing for histologic and histometric analyses under light microscopy and polarized light microscopy. Results: Root resorption was observed in all groups. GII exhibited the greatest loss of dental structure (P < .01), and inflammatory resorption was predominant in this group. Storage in milk showed poorer results than immediate replantation and storage in Euro-Collins solution (P < .01). The teeth stored in Euro-Collins solution presented similar extension of root resorption and periodontal ligament reorganization to those of immediately replanted teeth. Conclusions: The findings of this study suggest that the Euro-Collins solution is an adequate storage medium for keeping avulsed teeth for up to 8 hours before replantation. Crown Copyright (C) 2010 Published by Elsevier Inc on behalf of American Association of Oral and Maxillofacial Surgeons. All rights reserved. Oral Maxillofac Surg 68:111-119, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To verify the consequences of implant-supported fixed oral rehabilitation on the quality of life (QL) of elderly individuals. Material and methods: Fifteen patients were studied, being 10 females and five males; all were aged > 60 years, were completely edentulous, wore removable dentures on both arches, and were treated with implant-supported fixed dentures. Three QL questionnaires were applied, two related to the oral conditions (Oral Impact on Daily Performance - OIDP - and Oral Health Impact Profile, short version - OHIP-14) and one dealing with global aspects (World Health Organization Quality of Life - WHOQOL-BREF), before 3, 6, and 18 months after surgical placement of implants. Results: Scores in the OIDP and OHIP-14 questionnaires were better after dental treatment. The WHOQOL-BREF was less sensitive, confirming the higher reliability of specific questionnaires (focal) compared with general questions in such situations. Conclusion: Treatment with implant-supported fixed prostheses improved QL in the elderly; these effects are better detected by specific instruments focused on the subject.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze if the presence of impacted third molars, and their positions in the mandibular angle, can change the bone quality in this area, considering the measure of the cortical thickness in this region as representative or not for mandible fracture risk. Software was used to analyze 50 digital images from panoramic radiographs of patients who had one or two impacted third molars in the mandible, and 30 digital images of patients with agenesis of the mandibular third molar. The thickness of the cortical region of the mandible was measured; it was possible to draw a parallel line to the posterior portion of the mandible and a parallel line to the body of this bone on each side of the image. At the intersection of these lines near the distal portion of the second molar, another line was set up to serve as reference in the cortical thickness measurement. It could be concluded that the cortical thickness of the mandibular angle in male patients without impacted third molars was greater than the thickness in patients with these teeth, and no difference in thickness was found for the female group.