155 resultados para Equivalent circuits


Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Ayahuasca is a psychotropic plant beverage initially used by shamans throughout the Amazon region during traditional religious cult. In recent years, ayahuasca has also been used in ceremonies of a number of modern syncretic religious groups, including pregnant women. However, no documented study has been performed to evaluate the risk of developmental toxicity of ayahuasca. METHODS: In the present work, maternal and developmental toxicity was evaluated in Wistar rats. Ayahuasca was administered to pregnant rats in three different doses [the equivalent typical dose (TD) administered to humans, five-fold TD and 10-fold TD] during the gestational period (6-20 days). RESULTS: Dams treated with the highest ayahuasca dose showed maternal toxicity with decrease of weight gain and food intake. Visceral fetal findings were observed in all treatment groups. Skeletal findings were observed in the intermediate- and high-dose groups. The fetuses deriving from the highest dose group also presented a decrease in body weight. CONCLUSIONS: From these results, it is possible to conclude that there is a risk of maternal and developmental toxicity following ayahuasca exposure and that the level of toxicity appears to be dose-dependent. Birth Defects Res (Part B) 89:207-212, 2010. (C) 2010 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The objective of this study was to compare the superficial morphology of bovine and human sclerotic dentine. Design: For the morphological analysis, bovine (n = 3) and human (n = 3) incisors exhibiting exposed dentine were used. Dentine presented characteristics of sclerosis: brownish, smooth and shiny-the vitreous appearance. The teeth were prepared for assessment on a scanning electron microscope (SEM). Three pre-determined areas of each sample were submitted to SEM. The number of open tubules per area was obtained from the electron micrographs (n = 9 per group) for comparison purposes. Results: The number of open tubules in both species compared were similar (p > 0.05). Human dentine presented 31.89 +/- 23.94 open tubules per area, whereas bovine dentine showed 30.33 +/- 18.14 open tubules per area. Conclusion: Based on the results, we concluded that dentine exposed at the incisal surface of human and bovine teeth presented similar clinical and micro-morphological aspects, represented by surfaces with equivalent numbers of open dentinal tubules. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of light guide distance and the different photoactivation methods on the degree of conversion (DC) and microleakage of a composite. Methods and Materials: Three photoactivation protocols (600mW/cm(2) x 40 seconds; 400 mW/cm(2) x 60 seconds or 200 mW/cm(2) x 20 seconds, followed by 500 mW/cm(2) X 40 seconds) and three distances from the light source (0, 3 or 7 mm) were tested. Cylindrical specimens (5 nun diameter; 2 mm tall; n=3) were prepared for the DC test (FT-Raman). Class V cavities were made in 90 bovine incisors to conduct the microleakage test. The specimens were conditioned for 15 seconds with phosphoric acid (37%), followed by application of the adhesive system Prime & Bond NT (Dentsply/Caulk). The preparations were restored in bulk. The specimens were stored for 24 hours in distilled water (37 degrees C) before being submitted to the silvernitrate microleakage protocol. The restorations were sectioned and analyzed under 25x magnification. Results: Statistical analyses (two-way ANOVAs and Tukey test, alpha=0.05) found significance only for the factor distance (p=0.015) at the top of the composite for the DC test. Conversion was statistically lower for the 7 mm groups compared to the 0 and 3 mm groups, which were equivalent to each other. At the bottom of the specimens, none of the factors or interactions was significant (p<0.05). The Kruskal-Wallis test showed that, in general, the soft-start method led to lower microleakage scores when compared to the continuous modes, mainly when associated with a distancing of 7 mm (p<0.01). With the exception of specimens irradiated with 400mW/cm(2) that did not demonstrate variations on scores for the distances tested, higher microleakage was observed for shorter distances from the light source. Conclusions: Soft-start methods may reduce microleakage when the light guide distancing provides a low level of irradiance, which also causes a discrete reduction in the DC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A double-bind cross-over study was conducted on four healthy subjects, aged 19-29 years, in order to determine the relative bioavailability and other pharmacokinetics features of fluoride (F) after single oral administration in fasting conditions of 2 mg F as sodium F (NaF) or sodium monofluorophosphate (MFP). The bioavailability was evaluated on the basis of the plasma levels and of the urinary excretion of F. Blood was sampled before and during the 8 h after the administration of the test solutions. For F excretion urine was sampled 12 h before the study and over the 8 h after the administration. Data were tested for statistically significant differences by ANOVA and Tukey`s post hoc tests, and also by Student`s t-test (p < 0.05). For the two formulations, the pharmacokinetics of F in plasma was characterized by a rapid absorption and by a peak (C-max = 0.1 mu g/mL) which was reached 20 min after administration, followed by a biphasic elimination. In the 8 h following the administration the urinary excretion of F accounted for 35-41% of the administered dose, without significant differences between the two formulations. The AUCs (+/- S.D.) for NaF and MFP were 21.15 (+/- 0.58) and 19.04 (+/- 1.75) min mu g mL(-1), respectively, and were not significantly different (p = 0.079). Based on the AUC and C-max of F in plasma and on the urinary excretion of F during the 8 h following administration, the relative bioavailabilities of the two F formulations were equivalent. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the root canal preparation in flat-oval canals treated with either rotary or self-adjusting file (SAF) by using micro-tomography analysis. Methods: Forty mandibular incisors were scanned before and after root canal instrumentation with rotary instruments (n = 20) or SAF (n = 20). Changes in canal volume, surface area, and cross-sectional geometry were compared with preoperative values. Data were compared by independent sample t test and chi(2) test between groups and paired sample t test within the group (alpha = 0.05). Results: Overall, area, perimeter, roundness, and major and minor diameters revealed no statistical difference between groups (P > .05). In the coronal third, percentage of prepared root canal walls and mean increases of volume and area were significantly higher with SAF (92.0%, 1.44 +/- 0.49 mm(3), 0.40 +/- 0.14 mm(2), respectively) than rotary instrumentation (62.0%, 0.81 +/- 0.45 mm(3), 0.23 +/- 0.15 mm2, respectively) (P < .05). SAF removed dentin layer from all around the canal, whereas rotary instrumentation showed substantial untouched areas. Conclusions: In the coronal third, mean increases of area and volume of the canal as well as the percentage of prepared walls were significantly higher with SAF than with rotary instrumentation. By using SAF instruments, flat-oval canals were homogenously and circumferentially prepared. The size of the SAF preparation in the apical third of the canal was equivalent to those prepared with #40 rotary file with a 0.02 taper. (J Endod 2011;37:1002-1007)