156 resultados para COMPLEMENTARY EXPONENTIAL GEOMETRIC DISTRIBUTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Examination of the epidemiology and timing of trauma deaths has been deemed a useful method to evaluate the quality of trauma care. Objective: The purpose of this study was to evaluate the quality of trauma care in a regional trauma system and in a university hospital in Brazil by comparing the timing of deaths in the studied prehospital and in-hospital settings to those published for trauma systems in other areas. Methods: We analyzed the National Health Minister`s System of Deaths Information for the prehospital mortality and we retrospectively collected the demographics, timelines, and trauma severity scores of all in-hospital patients who died after admission through the Emergency Unit of Hospital das Clinicas de Ribeirao Preto between 2000 and 2001. Results. During the study period, there were 787 trauma fatalities in the city: 448 (56.9%) died in the prehospital setting and 339 (43.1%) died after being admitted to a medical facility. In 2 years, 238 trauma deaths occurred in the studied hospital, and we found a complete clinical set of data for 224 of these patients. The majority of deaths in the prehospital setting were caused by penetrating injuries (66.7%), whereas in-hospital mortality was mainly because of blunt traumas (59.1%). The largest number of in-hospital deaths occurred beyond 72 hours of stay (107 patients-47%). Conclusions: The region studied showed some deficiencies in prehospital and in-hospitals settings, in particular in the critical care and short-term follow-up of trauma patients when compared with the literature. Particularly, the late mortality may be related to training and human resources deficiency. Based on the timeline of trauma deaths, we can suggest that the studied region needs improvements in the prehospital trauma system and in hospital critical care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioelectrical impedance vector analysis (BIVA) is a new method that is used for the routine monitoring of the variation in body fluids and nutritional status with assumptions regarding body composition values. The aim of the present study was to determine bivariate tolerance intervals of the whole-body impedance vector and to describe phase angle (PA) values for healthy term newborns aged 7-28 d. This descriptive cross-sectional study was conducted on healthy term neonates born at a low-risk public maternity. General and anthropometric neonatal data and bioelectrical impedance data (800 mu A-50 kHz) were obtained. Bivariate vector analysis was conducted with the resistance-reactance (RXc) graph method. The BIVA software was used to construct the graphs. The study was conducted on 109 neonates (52.3% females) who were born at term, adequate for gestational age, exclusively breast-fed and aged 13 (SD 3.6) d. We constructed one standard, reference, RXc-score graph and RXc-tolerance ellipses (50, 75 and 95 %) that can be used with any analyser. Mean PA was 3.14 (SD 0.43)degrees (3.12 (SD 0.39)degrees for males and 3.17 (SD 0.48)degrees for females). Considering the overlapping of ellipses of males and females with the general distribution, a graph for newborns aged 7-28 d with the same reference tolerance ellipse was defined for boys and girls. The results differ from those reported in the literature probably, in part, due to the ethnic differences in body composition. BIVA and PA permit an assessment without the need to know body weight and the prediction error of conventional impedance formulas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. In view of the high prevalence of headache in the general population, the availability of well defined regarding the request of complementary exams is highly desirable. Aim. To analyze the criteria that will guide the physician requests of complementary exams during the investigation of headache. Patients and methods. The data were obtained by reviewing medical records of all patients who had been scheduled to be seen in a tertiary Headache Outpatient Clinic in 2004. Results. The exam most frequently requested was computed tomography of the head and the exams that most contributed to a change in clinical diagnosis or medical conduct were computed tomography of paranasal sinuses, simple rediography of paranasal sinuses. and magnetic resonance image of the brain. The exams that did not contribute to a change in the diagnosis or medical conduct were computed tomography and simple radiography of the cervical spine. As expected, the most expensive exams for the institution were computed tomography and magnetic resonance image. Conclusion. The importance of complementary exams in the investigation of headache is indisputable in many cases. Howerer, it is necessary the availability of more, studies that evaluate the request of complementay ; exams for headache patients. [REV NEUROL 2009: 48: 183-7]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The foramen of Vesalius (FV) is located in the greater wing of the sphenoid bone between the foramen ovale (FO) and the foramen rotundum in an intracranial view. The FO allows the passage of the mandibular branch of trigeminal nerve, which is the target of the trigeminal radiofrequency rhizotomy. We analyzed its location, morphology, morphometry and interrelation among other foramina. 400 macerated adult human skulls were examined. A digital microscope (Dino-Lite plus(A (R))) was used to capture images from the FV. A digital caliper was used to perform the measurements of the distance between the FV and other foramina (FO, foramen spinosum and the carotid canal) in an extracranial view of the skull base. In the 400 analyzed skulls, the FV was identified in 135 skulls (33.75%) and absent on both sides in 265 skulls (66.25%). The FV was observed present bilaterally in 15.5% of the skulls. The incidence of unilateral foramen was 18.25% of the skulls of which 7.75% on right side and 10.5% on left side. The diameter of the FV was measured and we found an average value of 0.65 mm, on right side 0.63 mm and on the left side 0.67 mm. We verified that positive correlations were statistically significant among the three analyzed distances. This study intends to offer specific anatomical data with morphological patterns (macroscopic and mesoscopic) to increase the understanding of the FV features as frequency, incidence and important distances among adjacent foramina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length. Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation. A vertical static load of 100 N was applied to the cantilever arm at the distances of 10, 15, and 20 mm from the center of the distal abutment and the absolute values of specific deformation were recorded. Different patterns of abutment deformation were observed according to the framework alloy. The Co-Cr alloy framework resulted in higher levels of abutment deformation than the silver-palladium alloy framework. Abutment deformation was higher with longer cantilever extensions. Physical properties of the alloys used for framework interfere with abutment deformations patterns. Excessively long cantilever extensions must be avoided. To cite this article:Jacques LB, Moura MS, Suedam V, Souza EAC, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses.Clin. Oral Impl. Res. 20, 2009; 737-741.doi: 10.1111/j.1600-0501.2009.01712.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.