143 resultados para defect distribution
Resumo:
The aim of this study is to determine the concentrations of lidocaine and its metabolite, monoethylglycine xylidide (MEGX), and of the enantiomers of bupivacaine in maternal and fetal compartments. Ten healthy pregnant women were submitted to epidural anesthesia. Drug concentrations were determined in the maternal vein, fetal umbilical artery and vein, and the placental intervillous space. The highest concentrations of the bupivacaine enantiomers lidocaine and of lidocaine and of its MEGX metabolite were detected in maternal plasma and in the placental intervillous space. The placental transfer was 33% for the (+)-(R)-bupivacaine enantiomer and 31% for the (-)-(S)-bupivacaine enantiomer. For lidocaine and its MEGX metabolite, respective placental transfers were 60% and 43%. Lidocaine concentration in the fetal umbilical vein was 1.46 times higher than in the fetal umbilical artery. The highest concentrations of lidocaine and its metabolite and of the enantiomers of bupivacaine were detected in the placental intervillous space. The higher lidocaine concentrations in the fetal umbilical vein than in the fetal umbilical artery suggest that there was tissue uptake of the drug or drug metabolization by the fetus.
Resumo:
Background: Examination of the epidemiology and timing of trauma deaths has been deemed a useful method to evaluate the quality of trauma care. Objective: The purpose of this study was to evaluate the quality of trauma care in a regional trauma system and in a university hospital in Brazil by comparing the timing of deaths in the studied prehospital and in-hospital settings to those published for trauma systems in other areas. Methods: We analyzed the National Health Minister`s System of Deaths Information for the prehospital mortality and we retrospectively collected the demographics, timelines, and trauma severity scores of all in-hospital patients who died after admission through the Emergency Unit of Hospital das Clinicas de Ribeirao Preto between 2000 and 2001. Results. During the study period, there were 787 trauma fatalities in the city: 448 (56.9%) died in the prehospital setting and 339 (43.1%) died after being admitted to a medical facility. In 2 years, 238 trauma deaths occurred in the studied hospital, and we found a complete clinical set of data for 224 of these patients. The majority of deaths in the prehospital setting were caused by penetrating injuries (66.7%), whereas in-hospital mortality was mainly because of blunt traumas (59.1%). The largest number of in-hospital deaths occurred beyond 72 hours of stay (107 patients-47%). Conclusions: The region studied showed some deficiencies in prehospital and in-hospitals settings, in particular in the critical care and short-term follow-up of trauma patients when compared with the literature. Particularly, the late mortality may be related to training and human resources deficiency. Based on the timeline of trauma deaths, we can suggest that the studied region needs improvements in the prehospital trauma system and in hospital critical care.
Resumo:
Few studies has been done using guided bone regeneration in maxillary sinus defects. Aim: To assess the bone repair process in surgical defects on the alveolar wall of the monkey maxillary sinus, which communicates with the sinus cavity, by using collagen membranes: Gen-derm - Genius Baumer, Pro-tape - Proline and autologous temporal fascia. Materials and Methods: In this prospective and experimental study, orosinusal communications were performed in four tufted capuchin monkeys (Cebus apella) and histologic analysis was carried out 180 days after. Results: In the defects without a cover (control), bone proliferation predominated in two animals and fibrous connective tissue predominated in the other two. In defects repaired with a temporal fascia flap, fibrous connective tissue predominated in three animals and bone proliferation predominated in one. In the defects repaired with Gen-derm or Pro-tape collagen membranes there was complete bone proliferation in three animals and fibrous connective tissue in one. Conclusions: Surgical defect can be repaired with both bone tissue and fibrous connective tissue in all study groups; collagen membranes was more beneficial in the bone repair process than temporal fascia or absence of a barrier.
Resumo:
Bioelectrical impedance vector analysis (BIVA) is a new method that is used for the routine monitoring of the variation in body fluids and nutritional status with assumptions regarding body composition values. The aim of the present study was to determine bivariate tolerance intervals of the whole-body impedance vector and to describe phase angle (PA) values for healthy term newborns aged 7-28 d. This descriptive cross-sectional study was conducted on healthy term neonates born at a low-risk public maternity. General and anthropometric neonatal data and bioelectrical impedance data (800 mu A-50 kHz) were obtained. Bivariate vector analysis was conducted with the resistance-reactance (RXc) graph method. The BIVA software was used to construct the graphs. The study was conducted on 109 neonates (52.3% females) who were born at term, adequate for gestational age, exclusively breast-fed and aged 13 (SD 3.6) d. We constructed one standard, reference, RXc-score graph and RXc-tolerance ellipses (50, 75 and 95 %) that can be used with any analyser. Mean PA was 3.14 (SD 0.43)degrees (3.12 (SD 0.39)degrees for males and 3.17 (SD 0.48)degrees for females). Considering the overlapping of ellipses of males and females with the general distribution, a graph for newborns aged 7-28 d with the same reference tolerance ellipse was defined for boys and girls. The results differ from those reported in the literature probably, in part, due to the ethnic differences in body composition. BIVA and PA permit an assessment without the need to know body weight and the prediction error of conventional impedance formulas.
Resumo:
Aim: To evaluate whether the ventricular septal defect (VSD) size, along with the degree of preoperative growth impairment and age at repair, may influence postoperative growth, and if VSD size can be useful to identify children at risk for preoperative failure to thrive. Methods: Sixty-eight children submitted to VSD repair in a Brazilian tertiary-care institution were evaluated. Weight and height measurements were converted to Z-scores. Ventricular septal defect size was normalized by dividing it by the aortic root diameter (VSD/Ao ratio). Results: Twenty-six patients (38%) had significantly low weight-for-height, 10 patients (15%) had significantly low height-for-age and 13 patients (19%) had both conditions at repair. Catch-up growth occurred in 82% of patients for weight-for-age, in 75% of patients for height-for-age and in 89% of patients for weight-for-height. Weight-for-height Z-scores at surgery were significantly lower in patients who underwent repair before 9 months of age. The VSD/Ao ratio did not associate with any other data. On multivariate analysis, weight-for-age Z-scores and age at surgery were independent predictors of long-term weight and height respectively. Conclusion: The VSD/Ao ratio was not a good predictor of preoperative failure to thrive. Most patients had preoperative growth impairment and presented catch-up growth after repair. Preoperative growth status and age at surgery influenced long-term growth.
Resumo:
To histomorphometrically investigate the repair of critical size defects (CSDs) and bone augmentation in cranial walls using block of sintered bovine-derived anorganic bone (sBDAB) graft. Forty guinea-pigs were divided into test (n=20) and CSD control (n=20) groups. In each animal, a full-thickness bone defect with 9.5 mm diameter was made in the frontal bone. The defects were filled with an sBDAB block soaked in blood in the test group and with blood clot in the CSD control group. The skulls were collected at 0 h (n=2) and 30, 90 and 180 days (n=6/group and period) postoperatively. The volume density and total volume of newly formed bone, sBDAB, blood vessels and connective tissue, vertical thickness of removed bone plug, sBDAB block and graft area were evaluated. The vertical thickness of the adapted sBDAB block was 3.8 times higher than that of the removed bone plug and did not show significant difference between periods, filling in average 29.8% of the total graft region. The sBDAB block exhibited complete osseointegration with the borders of the defect at 90 days. At 90 and 180 days, the vertical thickness of the graft was 279% in the average, and the total volume of bone augmentation was, respectively, 78.8% and 148.5% higher compared with the removed bone plug. The defects of the CDS control group showed limited osteogenesis and filling by connective tissue plus tegument. The sBDAB block can be used to promote repair of CSDs and bone augmentation in the craniomaxillofacial region, due to its good osteoconductive and slow resorptive properties. To cite this article:Cestari TM, Granjeiro JM, de Assis GF, Garlet GP, Taga R. Bone repair and augmentation using block of sintered bovine-derived anorganic bone graft in cranial bone defect model.Clin. Oral Impl. Res. 20, 2009; 340-350.doi: 10.1111/j.1600-0501.2008.01659.x.
Resumo:
The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length. Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation. A vertical static load of 100 N was applied to the cantilever arm at the distances of 10, 15, and 20 mm from the center of the distal abutment and the absolute values of specific deformation were recorded. Different patterns of abutment deformation were observed according to the framework alloy. The Co-Cr alloy framework resulted in higher levels of abutment deformation than the silver-palladium alloy framework. Abutment deformation was higher with longer cantilever extensions. Physical properties of the alloys used for framework interfere with abutment deformations patterns. Excessively long cantilever extensions must be avoided. To cite this article:Jacques LB, Moura MS, Suedam V, Souza EAC, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses.Clin. Oral Impl. Res. 20, 2009; 737-741.doi: 10.1111/j.1600-0501.2009.01712.x.
Resumo:
In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.