166 resultados para Pressure--Measurement.
Resumo:
High salt intake is a known cardiovascular risk factor and is associated with cardiac alterations. To better understand this effect, male Wistar rats were fed a normal (NSD: 1.3% NaCl), high 4 (HSD4: 4%), or high 8 (HSD8: 8%) salt diet from weaning until 18 wk of age. The HSD8 group was subdivided into HSD8, HSD8+HZ (15 mg.kg(-1).d(-1) hydralazine in the drinking water), and HSD8+LOS (20 mg.kg(-1).d(-1) losartan in the drinking water) groups. The cardiomyocyte diameter was greater in the HSD4 and HSD8 groups than in the HSD8+LOS and NSD groups. Interstitial fibrosis was greater in the HSD4 and HSD8 groups than in the HSD8+HZ and NSD groups. Hydralazine prevented high blood pressure (BP) and fibrosis, but not cardiomyocyte hypertrophy. Losartan prevented high BP and cardiomyocyte hypertrophy, but not fibrosis. Angiotensin II type 1 receptor (AT(1)) protein expression in both ventricles was greater in the HSD8 group than in the NSD group. Losartan, but not hydralazine, prevented this effect. Compared with the NSD group, the binding of an AT(1) conformation-specific antibody that recognizes the activated form of the receptor was lower in both ventricles in all other groups. Losartan further lowered the binding of the anti-AT(1) antibody in both ventricles compared with all other experimental groups. Angiotensin II was greater in both ventricles in all groups compared with the NSD group. Myocardial structural alterations in response to HSD are independent of the effect on BP. Salt-induced cardiomyocyte hypertrophy and interstitial fibrosis possibly are due to different mechanisms. Evidence from the present study suggests that salt-induced AT(1) receptor internalization is probably due to angiotensin II binding. J. Nutr. 140: 1742-1751, 2010.
Resumo:
Background: To evaluate the cardiopulmonary effects of positive end-expiratory pressure (PEEP) equalization to intra-abdominal pressure (IAP) in an experimental model of intra-abdominal hypertension (IAH) and acute lung injury (ALI). Methods: Eight anesthetized pigs were submitted to IAH of 20 mm Hg with a carbon dioxide insufflator for 30 minutes and then submitted to lung lavage with saline and Tween (2.5%). Pressure x volume curves of the respiratory system were performed by a low flow method during IAH and ALI, and PEEP was subsequently adjusted to 27 cm center dot H(2)O for 30 minutes. Results: IAH decreases pulmonary and respiratory system static compliances and increases airway resistance, alveolar-arterial oxygen gradient, and respiratory dead space. The presence of concomitant ALI exacerbates these findings. PEEP identical to AP moderately improved oxygenation and respiratory mechanics; however, an important decline in stroke index and right ventricle ejection fraction was observed. Conclusions: Simultaneous IAH and ALI produce important impairments in the respiratory physiology. PEEP equalization to AP may improve the respiratory performance, nevertheless with a secondary hemodynamic derangement.
Resumo:
Objectives We studied the relationship between changes in body composition and changes in blood pressure levels. Background The mechanisms underlying the frequently observed progression from pre-hypertension to hypertension are poorly understood. Methods We examined 1,145 subjects from a population-based survey at baseline in 1994/1995 and at follow-up in 2004/2005. First, we studied individuals pre-hypertensive at baseline who, during 10 years of follow-up, either had normalized blood pressure (PreNorm, n = 48), persistently had pre-hypertension (PrePre, n = 134), or showed progression to hypertension (PreHyp, n = 183). In parallel, we studied predictors for changes in blood pressure category in individuals hypertensive at baseline (n = 429). Results After 10 years, the PreHyp group was characterized by a marked increase in body weight (+5.71% [95% confidence interval (CI): 4.60% to 6.83%]) that was largely the result of an increase in fat mass (+17.8% [95% CI: 14.5% to 21.0%]). In the PrePre group, both the increases in body weight (+1.95% [95% CI: 0.68% to 3.22%]) and fat mass (+8.09% [95% CI: 4.42% to 11.7%]) were significantly less pronounced than in the PreHyp group (p < 0.001 for both). The PreNorm group showed no significant change in body weight (-1.55% [95% CI: -3.70% to 0.61%]) and fat mass (+0.20% [95% CI: -6.13% to 6.52%], p < 0.05 for both, vs. the PrePre group). Conclusions After 10 years of follow-up, hypertension developed in 50.1% of individuals with pre-hypertension and only 6.76% went from hypertensive to pre-hypertensive blood pressure levels. An increase in body weight and fat mass was a risk factor for the development of sustained hypertension, whereas a decrease was predictive of a decrease in blood pressure. (J Am Coll Cardiol 2010; 56: 65-76) (C) 2010 by the American College of Cardiology Foundation
Resumo:
Background. Foot deformities have been related to diabetic neuropathy progression but their influence on plantar distribution during dynamic tasks is not completely understood. The purpose of the present study was to investigate the influence of metatarsal head prominence and claw toes on regional plantar pressures during gait in patients with diabetic neuropathy Methods Seventy-one adults participated in this study categorized into three groups: a control group (CG, n = 32), patients with diabetic neuropathy without any foot deformities (DG, n = 20), and patients with diabetic neuropathy with metatarsal head prominence and/or claw toes (DMHG, n = 19). Plantar pressure variables (contact area, peak pressure, and maximum mean pressure) were evaluated during gait on rearfoot, midfoot, and forefoot using capacitive insoles (Pedar-X System, Novel Inc., Munich, Germany). A general linear model was applied to repeatedly measure and analyze variance relationships between groups and areas. Results. DMHG. presented larger contact areas at the forefoot and midfoot along with higher peak pressure at the rearfoot compared to the other two groups The DG showed higher mean pressure at the midfoot compared to:the other two groups. Conclusion. The coexistence of diabetic neuropathy and metatarsal head prominence in addition to claw toes, resulted in overloading the rearfoot and enhancing the contact area of forefoot and midfoot while walking. This plantar pressure distribution is a result of a different coordination pattern adopted in order to reduce plantar loads at the anterior parts of the foot that were structurally altered. Patients with diabetic neuropathy without any forefoot deformities presented a different plantar pressure distribution than patients with deformities suggesting that both neuropathy and structural foot alterations can influence foot rollover mechanisms.
Resumo:
The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The dorsolateral prefrontal cortex (DLPFC) has been implicated in the pathophysiology of mental disorders. Previous region-of-interest MRI studies that attempted to delineate this region adopted various landmarks and measurement techniques, with inconsistent results. We developed a new region-of-interest measurement method to obtain morphometric data of this region from structural MRI scans, taking into account knowledge from cytoarchitectonic postmortem studies and the large inter-individual variability of this region. MRI scans of 10 subjects were obtained, and DLPFC tracing was performed in the coronal plane by two independent raters using the semi-automated software Brains2. The intra-class correlation coefficients between two independent raters were 0.94 for the left DLPFC and 0.93 for the right DLPFC. The mean +/- S.D. DLPFC volumes were 9.23 +/- 2.35 ml for the left hemisphere and 8.20 +/- 2.08 ml for the right hemisphere. Our proposed method has high inter-rater reliability and is easy to implement, permitting the standardized measurement of this region for clinical research applications. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The aim of this paper is to study the correlation between the intraocular pressure peaks and fluctuation detected during the water drinking test and the same parameters observed during long-term follow up. This prospective cohort study enrolled 22 eyes of 22 newly diagnosed primary open angle glaucoma patients. After an initial complete ophthalmological examination, patients were started on antiglaucoma medication and returned 4 weeks later to perform the water drinking test. Thereafter, patients were evaluated at least eight times within a period of 6-12 months. The intraocular pressure peaks and fluctuation detected during the water drinking stress test were compared with those observed during regular office visits. Spearman`s correlation coefficient and Bland-Altman Plots were used for statistical analysis. The mean age of participants was 54.3 +/- 8.2 years (+/- SD), 59% were women, and average mean deviation -10.2 +/- 4.5 dB. The mean follow-up period was 8.2 +/- 2.0 months. The average intraocular pressure peaks and fluctuation during the water drinking test were 20.0 +/- 2.9 mmHg and 40 +/- 10%, respectively, and 18.1 +/- 2.8 mmHg and 30 +/- 10% during follow up. Spearman`s correlation coefficients were significant and strong between the intraocular pressure peaks and fluctuation detected during the water drinking test and during the follow-up period (P < 0.001, rho = 0.76 and 0.82, respectively). There was good agreement between the variables. The intraocular pressure peaks and fluctuation detected during the water drinking test showed significant correlation and agreement with the pressures observed during follow-up visits. Stress tests could be used to estimate long-term intraocular pressure variation.
Resumo:
Emerging data reveal that oral estrogen therapy can increase clinic blood pressure (BP) in postmenopausal women; however, it is important to establish its effects on ambulatory BP, which is a better predictor for target-organ damage. Besides estrogen therapy, aerobic training is widely recommended for post-menopausal women, and it can decrease ambulatory BP levels. This study was designed to evaluate the effect of aerobic training and estrogen therapy on the ambulatory BP of post-menopausal women. Forty seven healthy hysterectomized women were randomly divided (in a double-blind manner) into 4 groups: placebo-control (PLA-CO = 12), estrogen therapy-control (ET-CO = 14), placebo-aerobic training (PLA-AT = 12), and estrogen therapy-aerobic training (ET-AT = 09). The ET groups received estradiol valerate (1 mg/day) and the AT groups performed cycle ergometer, 3x/week at moderate intensity. Hormonal status (blood analysis), maximal cardiopulmonary exercise test (VO(2) peak) and ambulatory BP (24-h, daytime and nighttime) was evaluated before and 6 months after interventions. A significant increase in VO(2) peak was observed only in women who participated in aerobic training groups (+4.6 +/- 1.0 ml kg(-1) min(-1), P=0.00). Follicle-stimulating hormone was a significant decreased in the ET groups (-18.65 +/- 5.19 pg/ml, P=0.00), and it was accompanied by an increase in circulating estrogen (56.1 +/- 6.6 pg/ml). A significant increase was observed in the ET groups for daytime (P=0.01) and nighttime systolic BP (P=0.01), as well as nighttime diastolic BP (P = 0.02). However, daytime diastolic BP was increased only in the ET-CO group (+3.4 +/- 1.2 mmHg, P=0.04), and did not change in any other groups. No significant effect was found in ambulatory heart rate. In conclusion, aerobic training abolished the increase of daytime ambulatory BP induced by estrogen therapy in hysterectomized, healthy, normotensive and postmenopausal women. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Background: Obstructive sleep apnoea-hypopnoea syndrome (OSAHS) is a respiratory disorder with high morbidity and mortality. Continuous positive airway pressure (CPAP) is the most commonly prescribed conservative treatment for adults with OSAHS. CPAP therapy normalises or decreases OSAHS symptoms and can reduce and prevent OSAHS complications. Aims: To evaluate adherence to nasal CPAP treatment and CPAP impact on daytime drowsiness. Method: A sample of 20 patients evaluated for daytime drowsiness using the Epworth sleepiness scale and interviewed for adherence to nasal CPAP use. Results: There was a significant decrease in the level of daytime sleepiness of the patients users of nasal CPAP (p=0.017); patients not using nasal CPAP experienced a decrease without statistical significance (p=0.162). 100% of CPAP users reported benefits and 50% of these reported related discomforts. Conclusions: Patients with OSAHS that use CPAP have a greater reduced level of sleepiness than those who do not use it.
Resumo:
Background and objective The influence of ventilatory settings on static and functional haemodynamic parameters during mechanical ventilation is not completely known. The purpose of this study was to evaluate the effect of positive end-expiratory pressure, tidal volume and inspiratory to expiratory time ratio variations on haemodynamic parameters during haemorrhage and after transfusion of shed blood. Methods Ten anaesthetized pigs were instrumented and mechanically ventilated with a tidal volume of 8 ml kg(-1), a positive end-expiratory pressure of 5 cmH(2)O and an inspiratory to expiratory ratio of 1 : 2. Then, they were submitted in a random order to different ventilatory settings (tidal volume 16 ml kg(-1), positive end-expiratory pressure 15 cmH(2)O or inspiratory to expiratory time ratio 2: 1). Functional and static haemodynamic parameters (central venous pressure, pulmonary artery occlusion pressure, right ventricular end-diastolic volume and pulse pressure variation) were evaluated at baseline, during hypovolaemia (withdrawal of 20% of estimated blood volume) and after an infusion of withdrawn blood (posttransfusion). Results During baseline, a positive end-expiratory pressure of 15cmH(2)O significantly increased pulmonary artery occlusion pressure from 14.6 +/- 1.6 mmHg to 17.4 +/- 1.7 mmHg (P<0.001) and pulse pressure variation from 15.8 +/- 8.5% to 25.3 +/- 9.5% (P<0.001). High tidal volume increased pulse pressure variation from 15.8 8.5% to 31.6 +/- 10.4% (P<0.001), and an inspiratory to expiratory time ratio of 2: 1 significantly increased only central venous pressure. During hypovolaemia, high positive end-expiratory pressure influenced all studied variables, and high tidal volume strongly increased pulse pressure variation (40.5 +/- 12.4% pre vs. 84.2 +/- 19.1 % post, P<0.001). The inversion of the inspiratory to expiratory time ratio only slightly increased filling pressures during hypovolaemia, without without affecting pulse pressure variation or right ventricle end-diastolic volume. Conclusion We concluded that pulse pressure variation measurement is influenced by cyclic variations in intrathoracic pressure, such as those caused by augmentations in tidal volume. The increase in mean airway pressure caused by positive end-expiratory pressure affects cardiac filling pressures and also pulse pressure variation, although to a lesser extent. Inversion of the inspiratory to expiratory time ratio does not induce significant changes in static and functional haemodynamic parameters. Eur J Anaesthesiol 26:66-72 (c) 2009 European Society of Anaesthesiology.
Resumo:
Introduction Reduction of automatic pressure support based on a target respiratory frequency or mandatory rate ventilation (MRV) is available in the Taema-Horus ventilator for the weaning process in the intensive care unit (ICU) setting. We hypothesised that MRV is as effective as manual weaning in post-operative ICU patients. Methods There were 106 patients selected in the postoperative period in a prospective, randomised, controlled protocol. When the patients arrived at the ICU after surgery, they were randomly assigned to either: traditional weaning, consisting of the manual reduction of pressure support every 30 minutes, keeping the respiratory rate/tidal volume (RR/TV) below 80 L until 5 to 7 cmH(2)O of pressure support ventilation (PSV); or automatic weaning, referring to MRV set with a respiratory frequency target of 15 breaths per minute (the ventilator automatically decreased the PSV level by 1 cmH(2)O every four respiratory cycles, if the patient`s RR was less than 15 per minute). The primary endpoint of the study was the duration of the weaning process. Secondary endpoints were levels of pressure support, RR, TV (mL), RR/TV, positive end expiratory pressure levels, FiO(2) and SpO(2) required during the weaning process, the need for reintubation and the need for non-invasive ventilation in the 48 hours after extubation. Results In the intention to treat analysis there were no statistically significant differences between the 53 patients selected for each group regarding gender (p = 0.541), age (p = 0.585) and type of surgery (p = 0.172). Nineteen patients presented complications during the trial (4 in the PSV manual group and 15 in the MRV automatic group, p < 0.05). Nine patients in the automatic group did not adapt to the MRV mode. The mean +/- sd (standard deviation) duration of the weaning process was 221 +/- 192 for the manual group, and 271 +/- 369 minutes for the automatic group (p = 0.375). PSV levels were significantly higher in MRV compared with that of the PSV manual reduction (p < 0.05). Reintubation was not required in either group. Non-invasive ventilation was necessary for two patients, in the manual group after cardiac surgery (p = 0.51). Conclusions The duration of the automatic reduction of pressure support was similar to the manual one in the postoperative period in the ICU, but presented more complications, especially no adaptation to the MRV algorithm. Trial Registration Trial registration number: ISRCTN37456640
Resumo:
Background and objective: Dynamic indices represented by systolic pressure variation and pulse pressure variation have been demonstrated to be more accurate than filling pressures in predicting fluid responsiveness. However, the literature is scarce concerning the impact of different ventilatory modes on these indices. We hypothesized that systolic pressure variation or pulse pressure variation could be affected differently by volume-controlled ventilation and pressure-controlled ventilation in an experimental model, during normovolaemia and hypovolaemia. Method: Thirty-two anaesthetized rabbits were randomly allocated into four groups according to ventilatory modality and volaemic status where G1-ConPCV was the pressure-controlled ventilation control group, G2-HemPCV was associated with haemorrhage, G3-ConVCV was the volume-controlled ventilation control group and G4-HemVCV was associated with haemorrhage. In the haemorrhage groups, blood was removed in two stages: 15% of the estimated blood volume withdrawal at M1, and, 30 min later, an additional 15% at M2. Data were submitted to analysis of variance for repeated measures; a value of P < 0.05 was considered to be statistically significant. Results: At MO (baseline), no significant differences were observed among groups. At M1, dynamic parameters differed significantly among the control and hypovolaemic groups (P < 0.05) but not between ventilation modes. However, when 30% of the estimated blood volume was removed (M2), dynamic parameters became significantly higher in animals under volume-controlled ventilation when compared with those under pressure-controlled ventilation. Conclusions: Under normovolaemia and moderate haemorrhage, dynamic parameters were not influenced by either ventilatory modalities. However, in the second stage of haemorrhage (30%), animals in volume-controlled ventilation presented higher values of systolic pressure variation and pulse pressure variation when compared with those submitted to pressure-controlled ventilation.
Resumo:
Background: The Flutter (R) VRP1 combines high frequency oscillation and positive expiratory pressure (PEP). Objective: To separately evaluate the effect of the Flutter (R) VRP1 components (high frequency oscillation and PEP) on mucus transportability in patients with bronchiectasis. Methods: Eighteen patients with bronchiectasis received sessions with the Flutter (R) VRP1 or PEP for 30 min daily in a randomized, crossover study. The treatment duration was four weeks with one of the therapies, one week of a ""wash-out"" period and followed by four more weeks with the other treatment. Weekly secretion samples were collected and evaluated for mucociliary relative transport velocity (RTV), displacement in a simulated cough machine (SCM) and contact angle measurement (CAM). For the proposed comparisons, a linear regression model was used with mixed effects with a significance level of 5%. Results: The Flutter (R) VRP1 treatment resulted in greater displacement in SCM and lower CAM when comparing results from the first (9.6 +/- 3.4 cm and 29.4 +/- 5.7 degrees, respectively) and fourth weeks of treatment (12.44 +/- 10.5 cm and 23.28 +/- 6.2, respectively; p < 0.05). There was no significant difference in the RTV between the treatment weeks for either the Flutter (R) VRP1 or PEP. Conclusion: The use of the Flutter (R) VRP1 for four weeks is capable of altering the respiratory secretion transport properties, and this alteration is related to the high frequency oscillation component. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Pulmonary abnormalities are observed in chronic hepatopathy. The measurement of the maximum inspiratory and expiratory pressure may evaluate lung function and the risks associated with hepatic transplantation. Thus, the present work sought to evaluate the respiratory muscle strength of 29 patients between 17 and 63 years old who were enrolled for liver transplantation. The patients were classified according to Child-Turcotte-Pugh score as A, B, or C, and also according to a physiotherapeutic evaluation, which included measurement of respiratory muscle strength by means of a digital manovactrometer, which determines the maximum inspiratory pressure (MaxIP) and the maximum expiratory pressure (MaxEP). The tests were performed with seated individuals having their nostrils obstructed by a nasal clip. The MaxIP was measured during the effort initiated in the residual volume, whereas the MaxEP was measured during the effort initiated in the total pulmonary capacity, keeping pressures stable for at least 1 second. The statistical analysis was performed through using the Mann-Whitney test with a 5% level of significance. The MaxIP values of Child A 95.5 +/- 40.507 cm H2O (average +/- DP) and Child B 87.2 +/- 35.02 patients were higher than those for Child C patients (34.83 +/- 3.68; P <.05). Similar results were observed for the MaxEP of Child A and B groups (116.25 +/- 31.98 and 97.28 +/- 31.08, respectively; P <.05), versus the Child C group (48.16 +/- 22.60). Between groups A and B, the MaxEP were similar (P >.05). We concluded that Child C patients display muscle weakness significantly greater than that of subjects classified as Child A or B.
Resumo:
Chronic ethanol Consumption and hypertension are related. In the current study we investigated whether changes in reactivity of the mesenteric arterial bed could account for the increased blood pressure associated with chronic ethanol intake. Changes in reactivity to phenylephrine and acetylcholine were investigated in the perfused mesenteric bed from rats treated with ethanol for 2 or 6 weeks and their age-matched controls. Mild hypertension was observed in chronically ethanol-treated rats. Treatment of rats for 6 weeks induced an increase in the contractile response of endothelium-intact mesenteric bed to phenylephrine, but not denuded rat mesenteric bed. The phenylephrine-induced increase in perfusion pressure was not altered after 2 weeks` treatment with ethanol. Moreover, acetylcholine-induced endothelium-dependent relaxation was reduced by ethanol treatment for 6 weeks, but not 2 weeks. Pre-treatment with indometacin, a cyclooxygenase inhibitor, reduced the maximum effect induced by phenylephrine (E-max) in endothelium-intact mesenteric bed from both control and ethanol-treated rats. No differences in the E-max values for phenylephrine were observed between groups in the presence of indometacin. L-NNA, a nitric oxide (NO) synthase (NOS) inhibitor, increased the E-max for phenylephrine in endothelium-intact mesenteric bed from control rats but not from ethanol-treated rats. Levels of endothelial NOS (eNOS) mRNA were not altered by chronic ethanol consumption. However, chronic ethanol intake strongly reduced eNOS protein levels in the mesenteric bed. This study shows that chronic ethanol consumption increases blood pressure and alters the reactivity of the mesenteric bed. Moreover, the increased vascular response to phenylephrine observed in the mesenteric bed is maintained by two mechanisms: an increased release of endothelial-derived vasoconstrictor prostanoids and a reduced modulatory action of endothelial NO, which seems to be associated with reduced post-transcriptional expression of eNOS.