139 resultados para Eyewitness identification accuracy
Resumo:
Objectives: The diagnosis of caries lesions is still a matter of concern in dentistry. The diagnosis of dental caries by digital radiography has a number of advantages over conventional radiography; however, this method has not been explored fully in the field of paediatric dentistry. This in vitro research evaluated the accuracy of direct digital radiography compared with visual inspection and conventional radiography in the diagnosis of occlusal caries lesions in primary molars. Methods: 50 molars were selected and evaluated under standardized conditions by 2 previously calibrated examiners according to 3 diagnostic methods (visual inspection, conventional radiography and direct digital radiography). Direct digital radiographs were obtained with the Dixi3 system (Planmeca, Helsinki, Finland) and the conventional radiographs with InSight film (Kodak Eastman Co., Rochester, NY). The images were scored and a reference standard was obtained histologically. The interexaminer reliability was calculated using Cohen`s kappa test and the specificity, sensitivity and accuracy of the methods were calculated. Results: Examiner reliability was good. For lesions limited to the enamel, visual inspection showed significantly higher sensitivity and accuracy than both radiographic methods, but no significant difference was found in specificity. For teeth with dentinal caries, no significant differences were found for any parameter when comparing visual and radiographic evaluation. Conclusions: Although less accurate than the visual method for detecting caries lesions confined to the enamel, the direct digital radiographic method is as effective as conventional radiographic examination and visual inspection of primary teeth with occlusal caries when the dentine is involved. Dentomaxillofacial Radiology (2010) 39, 362-367. doi: 10.1259/dmfr/22865872
Resumo:
Introduction: The aim of this study was to compare the influence of preflaring on the accuracy of 4 electronic apex locators (EALs): Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex Locator, and Apex DSP. Methods: Forty extracted teeth were preflared by using S1 and SX ProTaper instruments. The working length was established by reducing 1 mm from the total length (TL). The ability of the EALs to detect precise (-1 mm from TL) and acceptable (-1+/-0.5 mm from TL) measurements in unflared and preflared canals was determined. Results: The precise and acceptable (P/A) readings in unflared canals for Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex and Apex DSP were 50%/97.5%, 47.5%/95%, 50%/97.5%, and 45%/67.5%, respectively. For preflared canals, the readings were 75%/97.5%, 55%/95%, 75%/97.5%, and 60%/87.5%, respectively. For precise criteria, the preflared procedure increased the percentage of accurate electronic readings for the Root ZX and the Mini Apex Locator (P < .05). For acceptable criteria, no differences were found among Root ZX, Elements Diagnostic Unit and Apex Locator, and Mini Apex Locator (P > .05). Fisher test indicated the lower accuracy for Apex DSP (P < .05). Conclusions: The Root ZX and the Mini Apex Locator devices increased significantly the precision to determine the real working length after the preflaring procedure. All the EALs showed an acceptable determination of the working length between the ranges of+/-0.5mm except for the Apex DSP device, which had the lowest accuracy. (J Endod 2009;35:1300-1302)
Resumo:
Objective: The objective of the study is to investigate the results of the newborn hearing screening program carried out in a Public Hospital in Brazil, in the first 3 years regarding: (1) the prevalence of hearing impairment; (2) the influence of the universal hearing screening program on the age at which the diagnosis of hearing loss is defined; (3) the cost effectiveness of the program; (4) the outcomes, in terms of the age in which the hearing rehabilitation started. Methods: A descriptive study of the first 3 years after starting the universal newborn hearing screening in a Public Hospital of Bauru, Sao Paulo state, Brazil. The screening method consists of a two-stage screening approach with transient otoacoustic emissions (TOAE), conducted by an audiologist. If the outcome in the second-stage screening is REFER, the infant is submitted to diagnostic follow-up testing and intervention at the Audiology and Speech Pathology Clinic at the University of Sao Paulo, campus of Bauru. The evaluation of the costs of the universal newborn hearing screening program per each screened newborn (around 4000/year) was done based on a proposal by the National Center for Hearing Assessment and Management, of the Utah State University, United States of America. Results: 11,466 newborns were submitted to hearing screening, corresponding to 90.52% of the living newborns. The prevalence of sensorineural hearing loss was 0.96:1000. Of the 11 children with sensorineural hearing loss, eight children received hearing aids and five started the therapeutic process before the age of 1. Currently, four children between the ages of 11 months and 2 years old were submitted to cochlear implant surgery. The cost of hearing screening was US$7.00 and the annual cost of the universal newborn hearing screening program was US$26,940.47. Conclusion: The hospital-based universal newborn hearing screening carried out through the Brazilian National Health System is viable, with promising results. However, in a country such as Brazil, which presents large socio-economic differences, the same type of analyses should be performed in several regions, so as to take into account specific aspects, to implement the newborn hearing screening along with the Public System. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.