163 resultados para BRASS ELECTRODES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Epidural motor cortex stimulation (MCS) has been used for treating patients with neuropathic pain resistant to other therapeutic approaches. Experimental evidence suggests that the motor cortex is also involved in the modulation of normal nociceptive response, but the underlying mechanisms of pain control have not been clarified yet. The aim of this study was to investigate the effects of epidural electrical MCS on the nociceptive threshold of naive rats. Electrodes were placed on epidural motor cortex, over the hind paw area, according to the functional mapping accomplished in this study. Nociceptive threshold and general activity were evaluated under 15-min electrical stimulating sessions. When rats were evaluated by the paw pressure test, MCS induced selective antinociception in the paw contralateral to the stimulated cortex, but no changes were noticed in the ipsilateral paw. When the nociceptive test was repeated 15 min after cessation of electrical stimulation, the nociceptive threshold returned to basal levels. On the other hand, no changes in the nociceptive threshold were observed in rats evaluated by the tail-flick test. Additionally, no behavioral or motor impairment were noticed in the course of stimulation session at the open-field test. Stimulation of posterior parietal or somatosensory cortices did not elicit any changes in the general activity or nociceptive response. Opioid receptors blockade by naloxone abolished the increase in nociceptive threshold induced by MCS. Data shown herein demonstrate that epidural electrical MCS elicits a substantial and selective antinociceptive effect, which is mediated by opioids. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Third molar extraction surgery is one of the most frequently performed procedures in the areas of buccal-maxillofacial traumatology and surgery. The post-surgery evolution was evaluated based on the clinical evidence obtained so far. The objective of this study was to analyze the post-surgery clinical evolution of the masseter muscle by means of surface electromyography, to evaluate muscle activity. Four analyses were performed: one pre-surgery, to register the normal activity, and three in post-surgery: on the 7(th), 14(th) and 21(st) postoperative days, in a sample of 30 patients. On the 21(st) day, there was near normal recovery of the electrical signal of the masseter in women, but in men this activity did not reach normal levels. Surface electromyography is a safe and reliable tool for post-surgery evolution control of masseter function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background & Aims: EPIC-3 is a prospective, international study that has demonstrated the efficacy of PEG-IFN alfa-2b plus weight-based ribavirin in patients with chronic hepatitis C and significant fibrosis who previously failed any interferon-alfa/ribavirin therapy. The aim of the present study was to assess FibroTest (FT), a validated non-invasive marker of fibrosis in treatment-naive patients, as a possible alternative to biopsy as the baseline predictor of subsequent early virologic (EVR) and sustained virologic response (SVR) in previously treated patients. Methods: Of 2312 patients enrolled, 1459 had an available baseline FT, biopsy, and complete data. Uni- (UV) and multi-variable (MV) analyses were performed using FT and biopsy. Results: Baseline characteristics were similar as in the overall population; METAVIR stage: 28% F2, 29% F3, and 43% F4, previous relapsers 29%, previous PEG-IFN regimen 41%, high baseline viral load (BVL) 64%. 506 patients (35%) had undetectable HCV-RNA at TW12 (TW12neg), with 58% achieving SVR. The accuracy of FT was similar to that in naive patients: AUROC curve for the diagnosis of F4 vs F2 = 0.80 (p<0.00001). Five baseline factors were associated (p<0.001) with SVR in UV and MV analyses (odds ratio: UV/MV): fibrosis stage estimated using FT (4.5/5.9) or biopsy (1.5/1.6), genotype 2/3 (4.5/5.1), BVL (1.5/1.3), prior relapse (1.6/1.6), previous treatment with non-PEG-IFN (2.6/2.0). These same factors were associated (p <= 0.001) with EVR. Among patients TW12neg, two independent factors remained highly predictive of SVR by MV analysis (p <= 0.001): genotype 2/3 (odds ratio = 2.9), fibrosis estimated with FT (4.3) or by biopsy (1.5). Conclusions: FibroTest at baseline is a possible non-invasive alternative to biopsy for the prediction of EVR at 12 weeks and SVR, in patients with previous failures and advanced fibrosis, retreated with PEG-IFN alfa-2b and ribavirin. (C) 2010 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background & Aims: Treatment with peginterferon alfa and ribavirin produces a sustained virologic response (SVR) in approximately 60% of hepatitis C virus (HCV)-infected patients. Alternate options are needed for patients who relapse or do not respond to therapy. Methods: This prospective, international, multicenter, open-label study evaluated efficacy and safety of peginterferon alfa-2b (1.5 mu g/kg/wk) plus weight-based ribavirin (800-1400 mg/day) in 2333 chronic HCV-infected patients with significant fibrosis/cirrhosis whose previous interferon alfa/ribavirin therapy failed. Patients with undetectable HCV-RNA at treatment week (TW) 12 received 48 weeks of therapy; patients with detectable HCV-RNA at TW12 could enter maintenance studies at TW18; 188 patients with low/detectable HCV-RNA at TW12 continued therapy at the investigator`s request. Results: Overall, 22% of the patients attained SVR (56% with undetectable HCV-RNA and 12% with low/detectable HCV-RNA at TW12). SVR was better in relapsers (38%) than nonresponders (14%), regardless of previous treatment, and in patients previously treated with interferon-alfa/ribavirin (25%) than peginterferon alfa-ribavirin (17%). Predictors of response in patients with undetectable HCV-RNA at TW12 were genotype (2/3 vs 1, respectively; odds ratio [OR] 2.4; P < .0001), fibrosis score (F2 vs F4; OR, 2.2; F3 vs F4; OR, 1.7; P < .0001), and baseline viral load (<= 600,000 vs >600,000 IU/mL; OR, 1.4; P = .0223). These factors plus previous treatment and response were overall predictors of SVR. Safety was similar among fibrosis groups. Conclusions: Peginterferon alfa-2b plus weight-based ribavirin is effective and safe in patients who failed interferon alfa/ribavirin therapy. Genotype, baseline viral load, and fibrosis stage were predictors of response.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Progesterone, estrogen and the hormonal complex of pregnancy have been responsible for some degree of colon hypomotility in human pregnancy. Objective: To find out if estrogen, progesterone and the hormonal complex of pregnancy decrease colon myoelectric activity. Methods: The study was performed in 37 healthy female rats in which electrodes were implanted on the serosa of the proximal ascendent, distal ascendent, transverse, and descendent colon. We analyzed the records of colon myoelectric activity in vivo in five groups: control, ovariectomized, ovariectomized and treated with estrogen, ovariectomized and treated with progesterone, and pregnant rats. Results: We found a great variation in myoelectric activity in all groups studied. The mean of electric activity did not show statistical difference among the five groups, but pregnant rats had a statistically significant higher duration of maximum electric activity in all distances from the cecocolon junction. Conclusion: Pregnant rats had a statistically higher duration of maximum electric activity. If we could transpose these results to humans, this increase in duration of colon myoelectric activity could explain, in part, the slight constipation that some pregnant women have. Copyright (C) 2008 S. Karger AG, Basel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the neural response in double-array cochlear implant as well as to describe the refractory recovery and the spread of excitation functions. In a prospective study 11 patients were implanted with the double-array cochlear implant. Neural response telemetry (NRT) was performed intra-operatively. NRT threshold could be registered in 6 of the 11 patients, at least in one electrode. The remaining five patients did not show measurable neural response intra-operatively. It was noted that although recovery and spread of excitation functions could be recorded in all the tested electrodes with measurable neural responses, the responses were shown to be different from the usual register in patients with other etiologies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conclusion. The study shows that there are differences in the measurement of the action potentials with and without the stylet in the Nucleus Freedom Contour Advance that are higher in the apex than in the base of the cochlea. Objectives. To determine if there are differences in the intraoperative impedances and in the neural response telemetry threshold values in the Nucleus Freedom Contour Advance before and after stylet removal. Subjects and methods. This was a prospective clinical study. Intraoperative impedances and neural response telemetry in users of the Freedom Contour Advance Cochlear Implant were measured before and after stylet removal. Results. There was a significant reduction in the impedance values of an average 1.5 k Omega +/- 2.3 in common ground mode and 1.3 k Omega +/- 2.3 for all monopolar modes after the stylet removal (p < 0.001). When analyzing the apical, medium, and basal electrodes, there was a statistically significant reduction in the neural response thresholds after stylet removal only in the apical electrodes (p = 0.001).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There remains a lack of solid evidence showing whether transcranial stimulation with weak alternating current (transcranial alternating current stimulation, tACS) can in fact induce significant neurophysiological effects. Previously, a study in which tACS was applied for 2 and 5 min with current density = 0.16-0.25 A/m(2) was unable to show robust effects on cortical excitability. Here we applied tACS at a significantly higher current density (0.80 A/m(2)) for a considerably longer duration (20 min) and were indeed able to demonstrate measurable changes to cortical excitability. Our results show that active 15 Hz tACS of the motor cortex (electrodes placed at C3 and C4) significantly diminished the amplitude of motor evoked potentials and decreased intracortical facilitation (ICF) as compared to baseline and sham stimulation. In addition, we show that our method of sham tACS is a reliable control condition. These results support the notion that AC stimulation with weak currents can induce significant changes in brain excitability; in this case, 15 Hz tACS led to a pattern of inhibition of cortical excitability. We propose that tACS may have a dampening effect on cortical networks and perhaps interfere with the temporal and spatial summation of weak subthreshold electric potentials. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: This study was conducted to investigate the success rate of using the facial motor evoked potential (FMEP) of orbicularis oculi and oris muscles for facial nerve function monitoring with use of a stepwise protocol, and its usefulness in predicting facial nerve outcome during cerebellopontine angle (CPA) surgeries. METHODS: FMEPs were recorded intraoperatively from 60 patients undergoing CPA surgeries. Transcranial electrocortical stimulation (TES) was performed using corkscrew electrodes positioned at hemispheric montage (C3/C4 and CZ). The contralateral abductor pollicis brevis muscle was used as the control response. Stimulation was always applied contralaterally to the affected side using 1, 3, or 5 rectangular pulses ranging from 200 to 600 V with 50 mu s of pulse duration and an interstimulus interval of 2 ms. Facial potentials were recorded from needles placed in the orbicularis oculi and oris muscles. RESULTS: FMEP from the orbicularis oris and oculi muscles could be reliably monitored in 86.7% and 85% of the patients, respectively. The immediate postoperative facial function correlated significantly with the FMEP ratio in the orbicularis oculi muscle at 80% amplitude ratio (P =.037) and orbicularis oris muscle at 35% ratio (P =.000). FMEP loss was always related to postoperative facial paresis, although in different degrees. CONCLUSION: FMEPs can be obtained reliably by using TES with 3 to 5 train pulses. Stable intraoperative FMEPs can predict a good postoperative outcome of facial function. However, further refinements of this technique are necessary to minimize artifacts and to make this method more reliable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of the present study was to explore the dynamics of the gamma band using the coherence of the quantitative electroencephalography (qEEG) in a sensorimotor integration task and the influence of the neuromodulator bromazepam on the band behavior. Our hypothesis is that the needs of the typewriting task will demand the coupling of different brain areas, and that the gamma band will promote the binding of information. It is also expected that the neuromodulator will modify this coupling. The sample was composed of 39 healthy subjects. We used a randomized double-blind design and divided subjects into three groups: placebo (n = 13), bromazepam 3 mg (n = 13) and bromazepam 6 mg (n = 13). The two-way ANOVA analysis demonstrated a main effect for the factors condition (i.e., C4-CZ electrode pair) and moment (i.e., C3-CZ, C3-C4 and C4-CZ pairs of electrodes). We propose that the gamma band plays an important role in the binding among several brain areas in complex motor tasks and that each hemisphere is influenced in a different manner by the neuromodulator. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our objective is to verify the modulatory effects of bromazepam on EEG theta absolute power when subjects were submitted to a visuomotor task (i.e., car driver task). Sample was composed of 14 students (9 males and 5 females), right handed, with ages varying between 23 and 42 years (mean = 32.5 +/- 9.5), absence of mental or physical impairments, no psychoactive or psychotropic substance use and no neuromuscular disorders (screened by a clinical examination). The results showed an interaction between condition and electrodes (p=0.034) in favor of F8 electrode compared with F7 in both experimental conditions (t-test; p=0.001). Additionally, main effects were observed for condition (p=0.001), period (p=0.001) and electrodes (p=0.031) in favor of F4 electrode compared with F3. In conclusion, Br 6 mg of bromazepam may interfere in sensorimotor processes in the task performance in an unpredictable scenario allowing that certain visuospatial factors were predominant. Therefore, the results may reflect that bromazepam effects influence the performance of the involved areas because of the acquisition and integration of sensory stimuli processes until the development of a motor behavior based on the same stimuli. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated the effects of bromazepam on qEEG when 14 healthy subjects were asked to perform a visuomotor task (i.e., motor vehicle driving task). The subjects were exposed to two experimental conditions: the placebo (PL) and 6 mg of bromazepam (Br 6 mg), following a randomized, double-blind design on different days. Specifically, we observe absolute power extracted from qEEG data for theta band. We expected to see a decrease in absolute theta power in the temporal and parietal areas due to the influence of bromazepam for the experimental group when compared with the placebo group. We found a main effect for the condition factor for electrodes T3, T4, P3 and P4. We also observed a main effect for the period factor for electrodes P3 and P4. We observed that the ingestion of 6 mg of bromazepam induces different patterns in theta power at the temporal and parietal sites. We concluded that 6 mg of bromazepam was an important factor in the fluctuation of the activities in the temporal and parietal areas. We then hypothesize about the specific role of this drug during the execution of a visuomotor task and within the sensorimotor integration process. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. A fundamental aspect of planning future actions is the performance and control of motor tasks. This behaviour is done through sensory-motor integration. Aim. To explain the electrophysiological mechanisms in the cortex (modifications to the alpha band) that are involved in anticipatory actions when individuals have to catch a free-falling object. Subjects and methods. The sample was made up of 20 healthy subjects of both sexes (11 males and 9 females) with ages ranging between 25 and 40 years (32.5 +/- 7.5) who were free of mental or physical diseases (previous medical history); the subjects were right-handed (Edinburgh Inventory) and were not taking any psychoactive or psychotropic substances at the time of the study. The experiment consisted in a task in which subjects had to catch freely falling objects. The experiment was made up of six blocks of 15 tests, each of which lasted 2 minutes and 30 seconds before and two seconds after each ball was dropped. Results. An interaction of the factors moment and position was only observed for the right parietooccipital cortex, in the combination of electrodes P4-O2. Conclusion. These findings suggest that the right parietooccipital cortex plays an important role in increasing expectation and swiftness in the process of preparing for a motor task.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Transcutaneous electrical nerve stimulation (TENS) is an effective adjunctive therapy for postoperative pain; however, effects of different frequencies Of stimulation have not been systematically investigated. Laparoscopic sterilization (LS) causes significant pain in the early postoperative period and requires substantial postoperative medication. Therefore, we studied the effects of TENS on postoperative pain after LS through placement of Yoon fallopian rings in a prospective, randomized, double-blinded, and placebo-controlled study. Methods: Sixty-four patients undergoing LS for uterine tube ligation were randomly allocated to receive either active TENS or placebo TENS. Postoperative pain was evaluated using a standard I I-point numeric rating scale and the McGill Pain Questionnaire (MPQ)-pain rating index and number of words chosen. Both high frequency (100 Hz) and low frequency (4 Hz) TENS, at strong, but comfortable sensory intensity, were applied for 20 minutes through 4 electrodes placed around the surgical incision immediately after Surgery. Pain was assessed before and after application of TENS when patients were at postanesthesia care unit (PACU). Results: Both high and low frequency TENS significantly decreased postoperative pain intensity when compared with before administration of TENS using the numeric rating scale (P = 0.001), pain rating index (P = 0.001), and number of words chosen (P 0.001) compared with placebo TENS (P = 0.001). TENS in combination with standard pharmacologic analgesic treatment was efficacious for postoperative pain relief after LS. Conclusions: We recommend regular use of multimodal therapy with TENS and analgesic drugs after LS with placement of Yoon rings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to compare SEMG activities during axial load exercises on a stable base of support and on a medicine ball (relatively unstable). Twelve healthy male volunteers were tested (x = 23 +/- 7y). Surface EMG was recorded from the biceps brachii, anterior deltoid, clavicular portion of pectoralis major, upper trapezius and serratus anterior using surface differential electrodes. All SEMG data are reported as percentage of RMS mean values obtained in maximal voluntary contractions for each muscle studied. A 3-way within factor repeated measures analysis of variance was performed to compare RMS normalized values. The RMS normalized values of the deltoid were always greater during the exercises performed on a medicine ball in relation to those performed on a stable base of support. The trapezius showed greater mean electric activation amplitude values on the wall-press exercise on a medicine ball, and the pectoralis major on the push-up. The serratus and biceps did not show significant differences of electric activation amplitude in relation to both tested bases of support. Independent of the base of support, none of the studied muscles showed significant differences of electric activation amplitude during the bench-press exercise. The results contribute to the identification of the levels of muscular activation amplitude during exercises that are common in clinical practice of rehabilitation of the shoulder and the differences in terms of type of base of support used. (C) 2006 Elsevier Ltd. All rights reserved.