16 resultados para presentation frameworks


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cow's milk is the most common food allergen in infants and the diagnosis of cow's milk allergy is difficult, even with the use of several diagnostic tests. Therefore, elimination diets and challenge tests are essential for the diagnosis and treatment of this disorder. The aim of this study is to report the clinical presentation and nutritional status of children evaluated by pediatric gastroenterologists for the assessment of symptoms suggestive of cow's milk allergy. Methods: An observational cross-sectional study was performed among 9,478 patients evaluated by 30 pediatric gastroenterologists for 40 days in 5 different geographical regions in Brazil. Clinical data were collected from patients with symptoms suggestive of cow's milk allergy. The nutritional status of infants (age <= 24 months) seen for the first time was evaluated according to z-scores for weight-for-age, weight-for-height, and height-for-age. Epi-Info (CDC-NCHS, 2000) software was used to calculate z-scores. Results: The prevalence of suspected cow's milk allergy in the study population was 5.4% (513/9,478), and the incidence was 2.2% (211/9,478). Among 159 infants seen at first evaluation, 15.1% presented with a low weight-for-age z score (< -2.0 standard deviation - SD), 8.7% with a low weight-for-height z score (< -2.0 SD), and 23.9% with a low height-for-age z score (< -2.0 SD). Conclusion: The high prevalence of nutritional deficits among infants with symptoms suggestive of cow's milk allergy indicates that effective elimination diets should be prescribed to control allergy symptoms and to prevent or treat malnutrition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neuropathic arthropathy (Charcot`s arthropathy) is a progressive articular disease associated with a reduced sensorial and protector proprioceptive reflex. Its etiology includes many different conditions such as syringomyelia, traumatic lesion causing medullary deformity, spina bifida, diabetic neuropathy, leprosy neuropathy, neurofibromatosis, amyloid neuropathy, alcohol, and repetitive injection of hydrocortisone into joints, among others. However, the relationship between Charcot`s arthropathy and herpetic encephalitis has not yet been described. Herpes encephalitis causes acute and chronic diseases of the peripheral or central nervous system. It can manifest as subacute encephalitis, recurrent meningitis, or myelitis. It can also resemble psychiatric syndromes, diplopia, sensory changes in the face and limbs, personality changes, frontal dysexecutive syndrome, stiff neck, subclinical alterations of the vestibular function, intracranial hypertension, convulsion, hemiparesis, and generally includes motor components, among others. On the other hand, pure peripheral sensory disturbance has not been described. In this article, we report the clinical case of a patient with Charcot`s arthropathy secondary to pure peripheral sensory polyneuropathy as a consequence of progressive herpetic encephalitis sequelae. In this article, the authors report the first case of Charcot`s arthropathy secondary to herpetic encephalitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

P>Context We previously described a six-generation family with G533C RET mutation and medullary thyroid carcinoma, in the largest family reported do date. Of particular interest, phenotype variability regarding the age of onset and clinical presentation of the disease, was observed. Objective We evaluate whether single SNPs within RET oncogene or haplotype comprising the RET variants (defined by Haploview) could predispose to early development of MTC in this family and influence the clinical manifestation. Design Eight SNPs were selected based on their previous association with the clinical course of hereditary or sporadic MTC, in particular promoting an early onset of disease. The variants were initially tested in 77 G533C-carriers and 100 controls using either PCR-direct sequencing or PCR-RFLP. Association between a SNP or haplotype and age at diagnosis or presence of lymph node metastasis was tested in 34 G533C-carries with MTC. Different bioinformatic tools were used to evaluate the potential effects on RNA splicing. Results An association was found between IVS1-126G > T and age at diagnosis. The variant [IVS8 +82A > G; 85-86 insC] was associated with the presence of lymph node metastases at diagnosis. In silico analysis suggested that this variant may induce abnormal splicing. This in silico analysis predicted that the [IVS8 +82A > G; 85-86 insC] could alter the splicing by disrupting and/or creating exonic splicing enhancer motifs. Conclusions We here identified two RET variants that were associated with phenotype variability in G533C-carriers, which highlights the fact that the modifier effect of a variant might depend on the type of mutation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traumatic transanal small bowel evisceration is a rare condition usually associated with suction injuries or blunt abdominal trauma. We report the first case of intestinal evisceration through the anus caused by penetrating trauma (rectal impalement). Additionally, we performed a literature review of all English language articles since 1970 concerned with traumatic transanal small bowel evisceration. Mechanisms of injury and the surgical management are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background A 38-year-old man with AIDS presented to hospital with a 3-month history of fevers, bilateral lumbar pain, dysuria and increased urinary frequency. Six years earlier he had received 6 months` treatment for pulmonary tuberculosis. At presentation, he was on antiretroviral therapy with a combination of efavirenz, stavudine and lamivudine. Investigations Physical examination, evaluation of HIV viral load, CD4 count, measurement of serum hemoglobin concentration, white blood cell count, urinalysis, urine culture for usual pathogens, direct smear and urine culture for Mycobacterium tuberculosis, chest radiography, abdominal CT, measurement of serum creatinine concentration and estimated creatinine clearance. Diagnosis Urogenital tuberculosis. Management The patient`s symptoms and radiological abnormalities persisted despite antibiotic therapy for presumed bacterial infection. After urine culture had confirmed M. tuberculosis infection, he was administered pharmacological treatment comprising isoniazid, rifampin, pyrazinamide and ethambutol for 2 months, with isoniazid and rifampin given for a further 7 months. His symptoms improved within a few days of initiating treatment. Six months after treatment started, CT revealed a nonfunctioning right kidney and a functional left kidney with areas of scarring. The patient refused right nephrectomy, and completed his pharmacological treatment. No evidence of disease recurrence was observed during 2 years of follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Autoinflammatory diseases are very rare diseases presenting within a wide clinical spectrum. Recognition of the main clinical features are challenging due to overlapping or mimicking with autoimmune diseases. Discussion: A case series is reviewed to illustrate typical and atypical features and the difficulties of these diagnoses in the low prevalence areas-a typical unrecognized case of familial Mediterranean fever (FMF) in a youngster, an atypical adult case with overlapping of IMF with Behcet disease, and an early presentation of FMF in infant presenting with inflammatory colitis, as well as the overlapping features within the cryopirin diseases spectrum in an 8-year-old boy who presented with systemic onset arthritis. Conclusion: These cases may represent examples of a very puzzling relationship among disorders of innate and adaptive immune systems and inflammation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The aim of this study was to evaluate the effect of thermal and mechanical cycling alone or in combination, on the flexural strength of ceramic and metallic frameworks cast in gold alloy or titanium. Methods. Metallic frameworks (25 mm x 3 mm x 0.5 mm) (N = 96) cast in gold alloy or commercial pure titanium (Ti cp) were obtained using acrylic templates. They were airborne particle-abraded with 150 mu m aluminum oxide at the central area of the frameworks (8 mm x 3 mm). Bonding agent and opaque were applied on the particle-abraded surfaces and the corresponding ceramic for each metal was fired onto them. The thickness of the ceramic layer was standardized by positioning the frameworks in a metallic template (height: I mm). The specimens from each ceramic-metal combination (N = 96, n = 12 per group) were randomly assigned into four experimental fatigue conditions, namely water storage at 37 degrees C for 24 h (control group), thermal cycling (3000 cycles, between 4 and 55 degrees C, dwell time: 10 s), mechanical cycling (20,000 cycles under 10 N load, immersion in distilled water at 37 degrees C) and, thermal and mechanical cycling. A flexural strength test was performed in a universal testing machine (crosshead speed: 1.5 mm/min). Data were statistically analyzed using two-way ANOVA and Tukey`s test (alpha = 0.05). Results. The mean flexural strength values for the ceramic-gold alloy combination (55 +/- 7.2MPa) were significantly higher than those of the ceramic-Ti cp combination (32 +/- 6.7 MPa) regardless of the fatigue conditions performed (p < 0.05). Mechanical and thermo-mechanical fatigue decreased the flexural strength results significantly for both ceramic-gold alloy (52 +/- 6.6 and 53 +/- 5.6 MPa, respectively) and ceramic-Ti cp combinations (29 +/- 6.8 and 29 +/- 6.8 MPa, respectively) compared to the control group (58 +/- 7.8 and 39 SA MPa, for gold and Ti cp, respectively) (p < 0.05) (Tukey`s test). While ceramic-Ti cp combinations failed adhesively at the metal-opaque interface, gold alloy frameworks exhibited a residue of ceramic material on the surface in all experimental groups. Significance. Mechanical and thermo-mechanical fatigue conditions decreased the flexural strength values for both ceramic-gold alloy and ceramic-Ti cp combinations with the results being significantly lower for the latter in all experimental conditions. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paracoccidioides brasiliensis rarely shows bone marrow involvement and its response to treatment with itraconazole in children needs further assessment. We describe here a child with a juvenile disseminated form of paracoccidioidomycosis, which showed reticuloendothelial system involvement and the presence of Paracoccidioides brasiliensis in the bone marrow. The patient showed an effective and rapid response to itraconazole therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to compare the accuracy of fit of three types of implant-supported frameworks cast in Ni-Cr alloy: specifically, a framework cast as one piece compared to frameworks cast separately in sections to the transverse or the diagonal axis, and later laser welded. Materials and Methods: Three sets of similar implant-supported frameworks were constructed. The first group of six 3-unit implant-supported frameworks were cast as one piece, the second group of six were sectioned in the transverse axis of the pontic region prior to casting, and the last group of six were sectioned in the diagonal axis of the pontic region prior to casting. The sectioned frameworks were positioned in the matrix (10 N(.)cm torque) and laser welded. To evaluate passive fit, readings were made with an optical microscope with both screws tightened and with only one-screw tightened. Data were submitted to ANOVA and Tukey-Kramer`s test (p < 0.05). Results: When both screws were tightened, no differences were found between the three groups (p > 0.05). In the single-screw-tightened test, with readings made opposite to the tightened side, the group cast as one piece (57.02 +/- 33.48 mu m) was significantly different (p < 0.05) from the group sectioned diagonally (18.92 +/- 4.75 mu m) but no different (p > 0.05) from the group transversally sectioned (31.42 +/- 20.68 mu m). On the tightened side, no significant differences were found between the groups (p > 0.05). Conclusions: Results of this study showed that casting diagonally sectioned frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves the levels of passivity to the same frameworks when compared to structures cast as one piece.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An inappropriate prosthetic fit could cause stress over the interface implant/bone. The objective of this study was to compare stresses transmitted to implants from frameworks cast using different materials and to investigate a possible correlation between vertical misfits and these stresses. Fifteen one-piece cast frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used for casting: CP Ti (commercially pure titanium), Co-Cr (cobalt-chromium) or Ni-Cr-Ti (nickel-chromium-titanium) alloys. Each framework was installed over the metal model with all screws tightened to a 10 N cm torque and then, vertical misfits were measured using an optical microscope. The stresses transmitted to implants were measured using quantitative photoelastic analysis in values of maximum shear stress (T), when each framework was tightened to the photoelastic model to a 10 N cm standardized torque. Stress data were statistically analyzed using one-way ANOVA and Tukey`s test and correlation tests were performed using Pearson`s rank correlation (alpha = 0.05). Mean and standard deviation values of vertical misfit are presented for CP Ti (22.40 +/- 9.05 mu m), Co-Cr (66.41 +/- 35.47 mu m) and Ni-Cr-Ti (32.20 +/- 24.47 mu m). Stresses generated by Co-Cr alloy (tau = 7.70 +/- 2.16 kPa) were significantly higher than those generated by CP Ti (tau = 5.86 +/- 1.55 kPa, p = 0.018) and Ni-Cr-Ti alloy (tau =5.74 +/- 3.05 kPa, p = 0.011), which were similar (p = 0.982). Correlations between vertical misfits and stresses around the implants were not significant as for any evaluated materials. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the vertical misfit of 3-unit implant-supported nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloy and commercially pure titanium (cpTi) frameworks after casting as 1 piece, after sectioning and laser welding, and after simulated porcelain firings. The results on the tightened side showed no statistically significant differences. On the opposite side, statistically significant differences were found for Co-Cr alloy (118.64 mu m [SD: 91.48] to 39.90 mu m [SD: 27.13]) and cpTi (118.56 mu m [51.35] to 27.87 mu m [12.71]) when comparing 1-piece to laser-welded frameworks. With both sides tightened, only Co-Cr alloy showed statistically significant differences after laser welding. Ni-Cr alloy showed the lowest misfit values, though the differences were not statistically significantly different. Simulated porcelain firings revealed no significant differences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

P>This study aimed to verify the effect of modified section method and laser-welding on the accuracy of fit of ill-fitting commercially pure titanium (cp Ti) and Ni-Cr alloy one-piece cast frameworks. Two sets of similar implant-supported frameworks were constructed. Both groups of six 3-unit implant-supported fixed partial dentures were cast as one-piece [I: Ni-Cr (control) and II: cp Ti] and evaluated for passive fitting in an optical microscope with both screws tightened and with only one screw tightened. All frameworks were then sectioned in the diagonal axis at the pontic region (III: Ni-Cr and IV: cp Ti). Sectioned frameworks were positioned in the matrix (10-Ncm torque) and laser-welded. Passive fitting was evaluated for the second time. Data were submitted to anova and Tukey-Kramer honestly significant difference tests (P < 0 center dot 05). With both screws tightened, one-piece cp Ti group II showed significantly higher misfit values (27 center dot 57 +/- 5 center dot 06 mu m) than other groups (I: 11 center dot 19 +/- 2 center dot 54 mu m, III: 12 center dot 88 +/- 2 center dot 93 mu m, IV: 13 center dot 77 +/- 1 center dot 51 mu m) (P < 0 center dot 05). In the single-screw-tightened test, with readings on the opposite side to the tightened side, Ni-Cr cast as one-piece (I: 58 center dot 66 +/- 14 center dot 30 mu m) was significantly different from cp Ti group after diagonal section (IV: 27 center dot 51 +/- 8 center dot 28 mu m) (P < 0 center dot 05). On the tightened side, no significant differences were found between groups (P > 0 center dot 05). Results showed that diagonally sectioning ill-fitting cp Ti frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves passivity levels of the same frameworks when compared to one-piece cast structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aspergillus is a frequently observed pathogen in patients with chronic granulomatous disease. We report on a patient with chronic granulomatous disease and severe brain aspergillosis with an unusual presentation and favorable course. We discuss the impact of this infection on morbidity and mortality, adequate therapeutic management, and the need to investigate a possible fungal infection, despite nonspecific signs. (C) 2010 by Elsevier Inc. All rights reserved.