36 resultados para Trik and self-deceit
Resumo:
This study evaluated in vitro the shear bond strength (SBS) of a resin-based pit-and-fissure sealant [Fluroshield (F), Dentsply/Caulk] associated with either an etch-and-rinse [Adper Single Bond 2 (SB), 3M/ESPE] or a self-etching adhesive system [Clearfil S3 Bond (S3), Kuraray Co., Ltd.] to saliva-contaminated enamel, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal enamel surfaces from 45 sound third molars were randomly assigned to 6 groups (n=15), according to the bonding technique: I - F was applied to 37% phosphoric acid etched enamel. The other groups were contaminated with fresh human saliva (0.01 mL; 10 s) after acid etching: II - SB and F were light cured separately; III - SB and F were light cured together; IV - S3 and F were light cured separately; V - S3 and F were light cured simultaneously; VI - F was applied to saliva-contaminated, acid-etched enamel without an intermediate bonding agent layer. SBS was tested to failure in a universal testing machine at 0.5 mm/min. Data were analyzed by one-way ANOVA and Fisher's test (α=0.05).The debonded specimens were examined with a stereomicroscope to assess the failure modes. Three representative specimens from each group were observed under scanning electron microscopy for a qualitative analysis. Mean SBS in MPa were: I-12.28 (±4.29); II-8.57 (±3.19); III-7.97 (±2.16); IV-12.56 (±3.11); V-11.45 (±3.77); and VI-7.47 (±1.99). In conclusion, individual or simultaneous curing of the intermediate bonding agent layer and the resin sealant did not seem to affect bond strength to saliva-contaminated enamel. S3/F presented significantly higher SBS than the that of the groups treated with SB etch-and-rinse adhesive system and similar SBS to that of the control group, in which the sealant was applied under ideal dry, noncontaminated conditions.
Resumo:
PURPOSE: Compare parents' reports of youth problems (PRYP) with adolescent problems self-reports (APSR) pre/post behavioral treatment of nocturnal enuresis (NE) based on the use of a urine alarm. MATERIALS AND METHODS: Adolescents (N = 19) with mono-symptomatic (primary or secondary) nocturnal enuresis group treatment for 40 weeks. Discharge criterion was established as 8 weeks with consecutive dry nights. PRYP and APSR were scored by the Child Behavior Checklist (CBCL) and Youth Self-Report (YSR). RESULTS: Pre-treatment data: 1) Higher number of clinical cases based on parent report than on self-report for Internalizing Problems (IP) (13/19 vs. 4/19), Externalizing Problems (EP) (7/19 vs. 5/19) and Total Problem (TP) (11/19 vs. 5/19); 2) Mean PRYP scores for IP (60.8) and TP (61) were within the deviant range (T score ≥ 60); while mean PRYP scores for EP (57.4) and mean APSR scores (IP = 52.4, EP = 49.5, TP = 52.4) were within the normal range. Difference between PRYP' and APSR' scores was significant. Post treatment data: 1) Discharge for majority of the participants (16/19); 2) Reduction in the number of clinical cases on parental evaluation: 9/19 adolescents remained within clinical range for IP, 2/19 for EP, and 7/19 for TP. 3) All post-treatment mean scores were within the normal range; the difference between pre and post evaluation scores was significant for PRYP. CONCLUSIONS: The behavioral treatment based on the use of urine alarm is effective for adolescents with mono-symptomatic (primary and secondary) nocturnal enuresis. The study favors the hypothesis that enuresis is a cause, not a consequence, of other behavioral problems.
Resumo:
Background: The Borg Scale may be a useful tool for heart failure patients to self-monitor and self-regulate exercise on land or in water (hydrotherapy) by maintaining the heart rate (HR) between the anaerobic threshold and respiratory compensation point. Methods and Results: Patients performed a cardiopulmonary exercise test to determine their anaerobic threshold/respiratory compensation points. The percentage of the mean HR during the exercise session in relation to the anaerobic threshold HR (%EHR-AT), in relation to the respiratory compensation point (%EHR-RCP), in relation to the peak HR by the exercise test (%EHR-Peak) and in relation to the maximum predicted HR (%EHR-Predicted) was calculated. Next, patients were randomized into the land or water exercise group. One blinded investigator instructed the patients in each group to exercise at a level between ""relatively easy and slightly tiring"". The mean HR throughout the 30-min exercise session was recorded. The %EHR-AT and %EHR-Predicted did not differ between the land and water exercisegroups, but they differed in the %EHR-RCP (95 +/- 7 to 86 +/- 7. P<0.001) and in the %EHR-Peak (85 +/- 8 to 78 +/- 9, P=0.007). Conclusions: Exercise guided by the Borg scale maintains the patient's HR between the anaerobic threshold and respiratory compensation point (ie, in the exercise training zone). (Circ J 2009; 73: 1871-1876)
Resumo:
The dynamics of a dissipative vibro-impact system called impact-pair is investigated. This system is similar to Fermi-Ulam accelerator model and consists of an oscillating one-dimensional box containing a point mass moving freely between successive inelastic collisions with the rigid walls of the box. In our numerical simulations, we observed multistable regimes, for which the corresponding basins of attraction present a quite complicated structure with smooth boundary. In addition, we characterize the system in a two-dimensional parameter space by using the largest Lyapunov exponents, identifying self-similar periodic sets. Copyright (C) 2009 Silvio L.T. de Souza et al.
Resumo:
Background: Depression in old age is a complex multifactorial phenomenon that is influenced by several biopsychosocial variables. Depressive symptoms are associated with the presence of chronic diseases, with being female, with low education and low income levels, and with poor perceived health assessment. In impoverished areas, older adults may have more physical disability, as they may have less access to health services. Therefore, they may be more likely to report depressive symptoms. Methods: Population-based cross-sectional research was undertaken using data from the FIBRA study conducted in Ermelino Matarazzo, a poor subdistrict of the city of Sao Paulo, Brazil. The participants comprised 303 elderly people, aged 65 years and over, who attended a single-session data collection effort carried out at community centers. The protocol comprised sociodemographic and self-reported health variables, and the Geriatric Depression Scale. Results: The majority of the subjects reported five or fewer symptoms of depression (79.21%), reported one or two self-reported chronic diseases (56.86%), declared themselves to have one or two self-reported health problems (46.15%), and had good perceived health assessment (40.27%). The presence of depressive symptoms was associated with a higher number of self-reported health problems, poor perceived health assessment, and lower schooling levels, in the total sample and in analyses including men only. For women, depressive symptoms were associated with the number of self-reported health problems and family income. Conclusion: The presence of health problems, such as falls and memory problems, lower perceived health, and low education (and low family income for women) were associated with a higher presence of depressive symptoms among elderly people in this poor area of Sao Paulo.
Resumo:
A cross-sectional study was carried out with 288 male blood donors, aged between 40 and 60 years old, with the aim of comparing the prevalence of erectile dysfunction (ED) as defined by the International Index of Erectile Function (IIEF) and that resulting from the simple questioning of the presence of ED. Socio-demographic, clinical, and behavioral factors that are associated with the presence of ED were considered. Erectile dysfunction prevalence in the IIEF was 31.9%, while self-reported ED prevalence was 3.1%. The factors associated to ED, as reported by the IIEF were: professional inactivity, suspected depression and/or anxiety, reduced sexual desired, and self-reported ED.
Resumo:
Background and Objectives: This study evaluated the hybrid layer (HL) morphology created by three adhesive systems (AS) on dentin surfaces treated with Er:YAG laser using two irradiation parameters. Study Design: Occlusal flat dentin surfaces of 36 human third molars were assigned into nine groups (n = 4) according to the following ASs: one bottle etch&rinse Single Bond Plus (3M ESPE), two-step Clearfil Protect Bond (Kuraray), and all-in-one S3 Bond (Kuraray) self-etching, which were labeled with rhodamine B or fluorescein isothiocyanate dextran and were applied to dentin surfaces that were irradiated with Er:YAG laser at either 120 (38.7 J/cm(2)) or 200 mJ/pulse (64.5 J/cm(2)), or were applied to untreated dentin surfaces (control group). The ASs were light-activated following MI and the bonded surfaces were restored with resin composite Z250 (3M ESPE). After 24 hours of storage in vegetable oil, the restored teeth were vertically, serially sectioned into 1-mm thick slabs, which had the adhesive interfaces analyzed with confocal laser microscope (CLSM-LSM 510 Meta). CLSM images were recorded in the fluorescent mode from three different regions along each bonded interface. Results: Non-uniform HL was created on laser-irradiated dentin surfaces regardless of laser irradiation protocol for all AS, while regular and uniform HL was observed in the control groups. ""Stretch mark""-like red lines were found within the HL as a result of resin infiltration into dentin microfissures, which were predominantly observed in 200 mJ/pulse groups regardless of AS. Poor resin infiltration into peritubular dentin was observed in most regions of adhesive interfaces created by all ASs on laser-irradiated dentin, resulting in thin resin tags with neither funnel-shaped morphology nor lateral resin projections. Conclusion: Laser irradiation of dentin surfaces at 120 or 200 mJ/pulse resulted in morphological changes in HL and resin tags for all ASs evaluated in the study. Lasers Surg. Med. 42:662-670, 2010. (C) 2010 Wiley-Liss, Inc.
Resumo:
Purpose: To evaluate early and 24-hour microtensile bond strength (mu TBS) and the degree of conversion (DC) of one representative adhesive system from each of the four current bonding approaches. Methods: 40 human molars were sectioned occluso-gingivally into two halves. Resin composite was bonded incrementally to flat, mid-coronal dentin, using the adhesives Adper Scotchbond MP (MP); Adper Scotchbond 2 (SB); Clearfil SE Bond (SE); and Adper Prompt L-Pop (LP) according to the respective manufacturer`s instructions (n= 10). One half was immediately sectioned into sticks and subjected to mu TBS test. As the sectioning process took approximately 1 hour, the results were designated as 1-hour bond strengths. The other half was stored in distilled water at 37 degrees C for 24 hours before being sectioned and tested. The DC of these systems was measured using Fourier Transform-Raman spectroscopy in three periods: immediately, 1 and 24 hours after polymerization. Data were analyzed with ANOVA and Tukey`s tests. Results: There were no significant differences between the 1-hour and 24-hour bond strengths (P> 0.05), or among the DC measured immediately, 1 hour and 24 hours after polymerization (P> 0.05). However, significant differences were observed among adhesives (P< 0.05). mu TBS values obtained, in MPa (1 hour/24 hour), were: SB (48.6 + 1.3/48.4 + 3.5) = SE (51.9 + 4.7/53.3 +/- 2.9) > MP (35.3 +/- 10.9/38.6 + 6.7) > LP (25.5 + 1.1/26.0 + 1.5). The DC, in percentage (immediately/1 hour/24 hour), were: SE (81/82/87) > MP (79/77/81) > SB (60/63/65) > LP (39/37/42).
Resumo:
Purpose: To evaluate the bond strength of glass fiber posts to intraradicular dentin when cemented with self-etching and self-adhesive resin cements. Materials and Methods: Forty-eight single-rooted human teeth were decoronated, endodontically treated, post-space prepared and divided into 8 groups (n = 6). The glass fiber posts used were: Exacto (EA) (Angelus) and everStick (ES) (StichTeck), which were cemented with two self-adhesive resin cements: BisCem (BIS) (Bisco) and Rely-X Unicem (UNI) (3M/ESPE), and two self-etching resin cements: Esthetic Cementing System NAC100 (NAC) (Kuraray) and Panavia-F (PAN) (Kuraray). Specimens were thermocycled between 5 degrees C and 55 degrees C for 1000 cycles and stored in water at 37 degrees C for 1 month. Four 1-mm-thick (in cross section) rods were obtained from the cervical region of the roots. Specimens were then subjected to microtensile testing in a special machine (BISCO; Schaumburg, IL, USA) at a crosshead speed of 0.5 mm/min. Microtensile bond strength (mu TBS) data were analyzed with two-way ANOVA and Tukey`s tests. Results: Means (and SD) of mu TBS (MPa) were: EA/PAN: 10.3 (4.1), EA/NAC: 14 (5.1) EA/BIS: 16.4 (4.8), EA/UNI: 19.8 (5.1), ES/PAN: 25.9 (6.1), ES/NAC: 29.1 (7), ES/BIS: 28.9 (6), ES/UNI: 30.5 (6.6). ANOVA indicated significant differences among the groups (p < 0.001). Mean mu TBS values obtained with ES post were significantly higher than those obtained with EA (p < 0.001). For EA, Tukey`s test indicated that higher mu TBS means were obtained with the self-adhesive resin cements (BIS and UNI), which were statistically significantly different (p < 0.05) from values obtained with the self-etching resin cements (PAN and NAC). Different cements had no significant effects on the bond strength values of ES post (p > 0.05). mu TBS values obtained with ES post were significantly higher than those obtained with EA post irrespective of the resin cement used. Conclusion: everStick posts resulted in the highest mean mu TBS values with all cements. Self-adhesive cements performed well in terms of bond strength.
Resumo:
This paper completes the review of the theory of self-adjoint extensions of symmetric operators for physicists as a basis for constructing quantum-mechanical observables. It contains a comparative presentation of the well-known methods and a newly proposed method for constructing ordinary self-adjoint differential operators associated with self-adjoint differential expressions in terms of self-adjoint boundary conditions. The new method has the advantage that it does not require explicitly evaluating deficient subspaces and deficiency indices (these latter are determined in passing) and that boundary conditions are of explicit character irrespective of the singularity of a differential expression. General assertions and constructions are illustrated by examples of well-known quantum-mechanical operators like momentum and Hamiltonian.
Resumo:
This article compares the efficiency of induced polarization (IP) and resistivity in characterizing a contamination plume due to landfill leakage in a typical tropical environment. The resistivity survey revealed denser electrical current flow that induced lower resistivity values due to the high ionic content. The increased ionic concentration diminished the distance of the ionic charges close to the membrane, causing a decrease in the IP phenomena. In addition, the self-potential (SP) method was used to characterize the preferential flow direction of the area. The SP method proved to be effective at determining the flow direction; it is also fast and economical. In this study, the resistivity results were better correlated with the presence of contamination (lower resistivity) than the IP (lower chargeability) data.
Resumo:
The aim of this study was to evaluate the relationship between malocclusion and self-perception of oral appearance/function, in 12/15-year-old Brazilian adolescents. The cluster sample consisted of 717 teenagers attending 24 urban public (n=611) and 5 rural public (n=107) schools in Maringá/PR. Malocclusion was measured using the Dental Aesthetic Index (DAI), in accordance with WHO recommendations. A parental questionnaire was applied to collect information on esthetic perception level and oral variables related to oral health. Univariate and multiple logistic regression analyses were performed. Multiple logistic regression confirmed that for 12-year-old, missing teeth (OR=2.865) and presence of openbite (open occlusal relationship) (OR=2.865) were risk indicators for speech capability. With regard to 15-year-old, presence of mandibular overjet (horizontal overlap) (OR=4.016) was a risk indicator for speech capability and molar relationship (OR=1.661) was a risk indicator for chewing capability. The impact of malocclusion on adolescents' life was confirmed in this study. Speech and chewing capability were associated with orthodontic deviations, which should be taken into consideration in oral health planning, to identify risk groups and improve community health services.
Resumo:
The purpose of this study was to evaluate the dentin shear bond strength of four adhesive systems (Adper Single Bond 2, Adper Prompt L-Pop, Magic Bond DE and Self Etch Bond) in regards to buccal and lingual surfaces and dentin depth. Forty extracted third molars had roots removed and crowns bisected in the mesiodistal direction. The buccal and lingual surfaces were fixed in a PVC/acrylic resin ring and were divided into buccal and lingual groups assigned to each selected adhesive. The same specimens prepared for the evaluation of superficial dentin shear resistance were used to evaluate the different depths of dentin. The specimens were identified and abraded at depths of 0.5, 1.0, 1.5 and 2.0 mm. Each depth was evaluated by ISO TR 11405 using an EMIC-2000 machine regulated at 0.5 mm/min with a 200 Kgf load cell. We performed statistical analyses on the results (ANOVA, Tukey and Scheffé tests). Data revealed statistical differences (p < 0.01) in the adhesive and depth variation as well as adhesive/depth interactions. The Adper Single Bond 2 demonstrated the highest mean values of shear bond strength. The Prompt L-Pop product, a self-etching adhesive, revealed higher mean values compared with Magic Bond DE and Self Etch Bond adhesives, a total and self-etching adhesive respectively. It may be concluded that the shear bond strength of dentin is dependent on material (adhesive system), substrate depth and adhesive/depth interaction.
Resumo:
The influence of socioeconomic factors and self-rated oral health on children's dental health assistance was assessed. This study followed a cross-sectional design, with a multistage random sample of 792 12-year-old schoolchildren from Santa Maria, a city in southern Brazil. A dental examination provided information on the prevalence of dental caries (DMFT index). Data about the use of dental service, socioeconomic status, and self-perceived oral health were collected by means of structured interviews. These associations were assessed using Poisson regression models (prevalence ratio; 95% confidence interval). The prevalence of regular use of dental service was 47.8%. Children from low socioeconomic backgrounds and those who rated their oral health as "poor" used the service less frequently. The distribution of the kind of oral healthcare assistance used (public/private) varied across socioeconomic groups. The better-off children were less likely to have used the public service. Clinical, socioeconomic, and psychosocial factors were strong predictors for the utilization of dental care services by schoolchildren.
Resumo:
OBJETIVO: Avaliar a validade do peso, estatura e Índice de Massa Corporal (IMC) referidos e sua confiabilidade para o diagnóstico do estado nutricional de adolescentes de Piracicaba. MÉTODOS: Participaram do estudo 360 adolescentes de ambos os sexos, de escolas públicas de Piracicaba, com idade entre 10 e 15 anos. Os adolescentes auto-relataram seu peso e estatura, sendo esses valores obtidos por medidas diretas, logo em seguida, pelos entrevistadores. A validade do IMC referido foi calculada segundo índices de sensibilidade, especificidade e valor preditivo positivo (VPP). Avaliou-se a concordância entre as categorias de IMC obtido por meio das medidas referidas e aferidas a partir do coeficiente kappa ponderado, coeficiente de correlação de Lin. e gráficos de Bland e Altman e Lin. RESULTADOS: Verificou-se que tanto os meninos quanto as meninas subestimaram o peso (-1,0 meninas e meninos) e a estatura (meninas -1,2 e meninos -0,8) (p < 0,001). Os valores de IMC aferidos e referidos apresentaram uma concordância moderada. A sensibilidade do IMC referido para classificar os indivíduos obesos foi maior para os meninos (87,5%), enquanto a especificidade foi maior para as meninas (92,7%). O VPP foi elevado somente para a classificação da eutrofia. CONCLUSÕES: As medidas referidas de peso e estatura de adolescentes não representam medidas válidas e, portanto, não devem ser usadas em substituição aos valores mensurados. Além disso, verificou-se que 10% dos meninos obesos e 40% das meninas obesas poderiam permanecer não identificados utilizando-se as medidas auto-referidas, confirmando a baixa validade das medidas auto-referidas.