54 resultados para SINGLETON PREGNANCIES


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Placental insufficiency and fetal growth restriction may lead to fetal hypoxia and acidemia, which result in fetal cardiac injury. Objective: The goal of this study was to compare the levels of fetal cardiac troponin T (cTnT) at birth and fetal Doppler parameters according to fetal gender in pregnancies complicated by placental insufficiency before 34 weeks` gestation. Methods: Between March 2007 and November 2010, singleton pregnancies with placental insufficiency characterized by abnormal umbilical artery Doppler results were prospectively studied. All the patients delivered by cesarean section, and Doppler examinations were performed up to 48 hours before birth. Immediately after delivery, umbilical artery blood samples were obtained for fetal cTnT measurements. Results: Fifty high-risk pregnant women met the study criteria. The study groups were as follows: group 1 consisted of 23 male fetuses (46%) and group 2 consisted of 27 female fetuses (54%). cTnT levels were significantly higher in the group of male fetuses (median, 0.14; range, 0.01-0.85) compared with the group of female fetuses (median, 0.05; range, 0.01-0.27) (P = 0.039). In the group of male fetuses, Doppler results of the ductus venosus assessment revealed values of pulsatility index for veins >= 1.0 in 15 male fetuses (65.2%) and 9 female fetuses (33.3%) (P = 0.032). Conclusions: Fetal gender was associated with cTnT level at birth in pregnancies complicated by placental insufficiency before 34 weeks` gestation, although the Doppler findings did not support gender differences. The fetal cardiac compromise and cardiac injury may be influenced by fetal gender, suggesting differences in the cardiovascular response to fetal hypoxia. (Gend Med. 2011;8:202-208) (C) 2011 Elsevier HS Journals, Inc. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: To evaluate the effect of maternal oral hydration on amniotic fluid index (AFI) in pregnancies with fetal gastroschisis. Methods: AFI was evaluated at 24-hour intervals, during 4 consecutive days, under a continuous maternal oral water hydration regimen, in singleton pregnancies with isolated fetal gastroschisis. Results: Nine pregnancies were examined at a mean gestational age of 31.6 weeks (+/-1.4) and mean maternal daily oral water intake was 3,437 (+/-810) ml. Mean AFI on days 0-3 were 13.2 (+/-2.9), 14.8 (+/-3.3), 14.5 (+/-3.1) and 14.8 (+/-2.6), respectively. AFI on day 0 was significantly lower compared to all the other 3 days (p = 0.01 and 0.02). Significant correlation was found in relative difference in AFI between day 0 and day 1 and gestational age (r = -0.67, p = 0.05) and the amount of water intake in the previous 24 h (r = 0.76, p = 0.02). Conclusion: Maternal oral water hydration significantly increases AFI in pregnancies with isolated fetal gastroschisis. Copyright (C) 2010 S. Karger AG, Basel

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective. The purpose of this study was to construct nomograms of placental volumes according to gestational age and estimated fetal weight. Methods. From March to November 2007, placental volumes were prospectively measured by ultrasonography in 295 normal pregnancies from 12 to 40 weeks` gestation and correlated with gestational age and estimated fetal weight. Inclusion criteria were healthy women, singleton pregnancies with normal fetal morphologic characteristics on ultrasonography, and confirmed gestational age by first-trimester ultrasonography. Results. The mean placental volume ranged from 83 cm(3) at 12 weeks to 427.7 cm(3) at 40 weeks. Linear regression yielded the following formula for the expected placental volumes (ePV) according to gestational age (GA): ePV` (cm(3)) = -64.68 + 12.31 x GA (r = 0.572; P < .001). Placental volumes also varied according to estimated fetal weight (EFW), and the following mathematical equation was also obtained by linear regression: ePV = 94.19 + 0.09 x EFW (r = 0.505; P < 0.001). Conclusions. Nomograms of placental volumes according to gestational age and estimated fetal weight were constructed, generating reference values.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objectives. To examine the effects of betamethasone administration on umbilical artery (UA), middle cerebral artery (MCA) and ductus venosus (DV) Doppler flow. Design. Longitudinal prospective study. Setting: Fetal Surveillance Unit, Department of Obstetrics and Gynecology, University of Sao Paulo, Sao Paulo, Brazil. Population. Thirty-two singleton pregnancies complicated by fetal growth restriction with absent end-diastolic flow in the UA. Methods. Pulsatility index (PI) of the UA, MCA and DV was measured from 26 to 34 weeks prior to and within 24 or 48 hours after starting betamethasone treatment course. Analysis of variance for repeated measures was used to determine the changes in the fetal hemodynamic Doppler flow following maternal corticosteroid administration. Main outcome measures. Improvement of UA-PI within 24 hours and DV-PIV (venous pulsatility) within 48 hours from the first betamethasone dose. Results. Mean gestational age at delivery was 29.3 (1.8) weeks and birthweight was 806.6 (228.2) g. A reduction in the UA-PI was observed in 29 (90.6%) cases, with return of end-diastolic flow in 22 (68.7%). The mean UA-PI were 2.84 (0.52) before corticosteroid administration, 2.07 (0.56) within 24 hours and 2.42 (0.75) after 48 hours, with a significant difference along the evaluations (p0.001). No significant changes in the MCA Doppler were observed. DV-PIV decreased from 1.06 (0.23) prior corticosteroids administration to 0.73 (0.16) within 24 hours and 0.70 (0.19) after 48 hours (p0.001). Conclusions. There was reduction in the umbilical artery and in the DV pulsatility indices within 24 hours from betamethasone administration that was maintained up to 48 hours.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives This study was designed to evaluate bowel diameter as a predictor of adverse outcome in isolated fetal gastroschisis Methods Retrospective study involving 94 singleton pregnancies Ultrasound measurements of herniated bowel transverse diameter (BTD) were performed up to 3 weeks before delivery Adverse outcome was intrauterine/neonatal death and/or bowel complications Results Last BTD was recorded at 35 6 +/- 1 6 weeks and mean interval to delivery was 6 2 +/- 5 0 days Intrauterine/neonatal death occurred in 10 (10 6%) cases, bowel complications were observed in 8 (8 5%) BTD >= 15, >= 20, >= 25, and >= 30 mm were found in 87, 46, 13, and 4% of pregnancies with a favorable outcome. respectively BTD >= 25 mm sensitivity was 38%. and positive and negative predictive values were 38 and 87% For BTD >= 30 mm. the values were 19, 50, and 85% Observed/expected BTD ROC curve showed an area of 0 67, best cut-off value at 1 39, prediction values were similar to those for BTD >= 25 mm Bowel dilatation was also significantly associated with lower rate of primary surgical closure. longer period to full oral feeding, and prolonged hospital stay Conclusions Bowel dilatation demonstrated up to 3 weeks before delivery is a predictor of intestinal complications and is associated with lower late of primary surgical closure, longer period to achieve full oral feeding. and hospital stay Copyright (C) 2010 John Wiley & Sons, Ltd

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. To correlate Doppler results with hematological indices at birth in small-for-gestational-age (SGA) fetuses. Design. Prospective study. Setting. Tertiary teaching hospital, Sao Paulo, Brazil. Population. One hundred singleton pregnancies with SGA fetuses of > 27 weeks gestational age. Methods. All women had Doppler velocimetry of the umbilical arteries, middle cerebral artery, and ductus venosus within < 72 hours prior to delivery. After birth, umbilical artery blood was collected for hematological analysis. Main outcome measures. The association between fetal Doppler velocimetry pulsatility index (PI) and some hematological indices. Results. Umbilical artery PI showed a positive correlation with nucleated red blood cell count in the umbilical cord (r = 0.46; p<0.01), and a negative correlation with platelet count (r = -0.53; p<0.01) and white blood cell count (r = -0.42; p<0.01). Middle cerebral artery PI was positively correlated with platelet count (r = 0.43; p<0.01) and white blood cell count (r = 0.38; p<0.01), and was negatively correlated with nucleated red blood cell count (r = -0.39; p<0.01). The ductus venosus pulsatility index showed a positive correlation with nucleated red blood cell count (r = 0.36; p<0.01), and a negative correlation with platelet count (r = -0.37; p<0.01) and white blood cell count (r = -0.26; p<0.01). Conclusion. A significant positive or negative correlation between nucleated red blood cell, platelet and white blood cell counts, and Doppler indices suggests an association between placental insufficiency and the fetal hematological response.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective To determine normal blood flow velocities across the fetal tricuspid valve (TV) at 11-13 weeks and 6 days of gestation and to examine the reproducibility of these measurements. Methods A prospective study involving 166 normal singleton pregnancies examined at 11-13 weeks and 6 days was carried out. Descriptive analysis of E- and A-waves` maximum velocities, E/A ratio, duration of the cardiac cycle (C) and diastole (D) and D/C ratio were calculated. Intraobserver and interobserver agreement analysis was performed in a subgroup of 12 cases. Results Average (+/- SD) flow velocities were: E-wave, 25.0 (+/- 4.6) cm/s; A-wave. 42.9 (+/- 5.9) cm/s; E/A, 0.58 (+/- 0.07); cardiac cycle, 390 (+/- 21.1) ms; diastole, 147 (+/- 18) ms and D/C, 0.38 (+/- 0.04). Significant correlation was observed between all parameters (except A-wave) and gestational age but not with nuchal translucency (NT). Intraclass correlation coefficients (interobserver, intraobsever examiner I and intraobserver examiner 2) were: E-wave, 0.53, 0.53 and 0.64; A-wave, 0.45, 0.46 and 0.49; cardiac cycle, 0.70, 0.79 and 0.84 and diastole, 0.63, 0.85 and 0.82, respectively. Conclusions The present study establishes normal Doppler parameters for blood flow across the TV at 11 - 13 weeks and 6 days and demonstrates that these parameters do not correlate with NT measurement and have good/moderate reproducibility. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective To evaluate the reliability of two- and three-dimensional ultrasonographic measurement of the thickness of the lower uterine segment (LUS) in pregnant women by transvaginal and transabdominal approaches. Methods This was a study of 30 pregnant women who bad bad at least one previous Cesarean section and were between 36 and 39 weeks` gestation, with singleton pregnancies in cephalic presentation. Sonographic examinations were performed by two observers using both 4-7-MHz transabdominal and 5-8-MHz transvaginal volumetric probes. LUS measurements were performed using two- and three-dimensional ultrasound, evaluating the entire LUS thickness transabdominally and the LUS muscular thickness transvaginally. Each observer measured the LUS four times by each method. Reliability was analyzed by comparing the mean of the absolute differences, the intraclass correlation coefficients, the 95% limits of agreement and the proportion of differences <1 mm. Results Transvaginal ultrasound provided greater reliability in LUS measurements than did transabdominal ultrasound. The use of three-dimensional ultrasound improved significantly the reliability of the LUS muscular thickness measurement obtained transvaginally. Conclusions Ultrasonographic measurement of the LUS muscular thickness transvaginally appears more reliable than does that of the entire LUS thickness transabdominally. The use of three-dimensional ultrasound should be considered to improve measurement reliability. Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To investigate the influence of maternal glycemia on fetal heart rate (FHR) parameters analyzed by computerized cardiotocography in fetuses of diabetic mothers in the third trimester. Study design: Thirty-nine pregnant women with pregestational diabetes mellitus were studied prospectively. The inclusion criteria were a diagnosis of pregestational diabetes, singleton pregnancy between 36 and 40 weeks, and absence of fetal abnormalities. Computerized cardiotocography (System 8002) was performed over a period of 60 min and capillary glycemia was measured immediately before and 30 and 60 min after the beginning of the exam. The evaluations were done 2 h after lunch. Results: Nineteen patients (48.7%) presented mean glycemia >= 120 mg/dL The mean basal FHR was 136.7 +/- 10.0 bpm in the group with glycemia <120 mg/dL and 144.8 +/- 9.4 bpm in the group with glycemia >= 120 mg/dL (p = 0.013, Student`s t test). There was a significant positive correlation (Pearson`s test, p = 0.0001, r = 0.57) between basal FHR and mean glycemia. A significant negative correlation was observed between short-term variation and mean glycemia (Pearson`s test, p = 0.003, r = -0.47). No significant differences were observed between the other indices evaluated by computerized cardiotocography and glycemia. Conclusions: Maternal hyperglycemia at the time of cardiotocography is associated with elevated FHR. It seems to be important to understand how FHR parameters are influenced by maternal glycemic status at the time of fetal assessment in pregnancies complicated by diabetes. (C) 2009 Published by Elsevier Ireland Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The occurrence of chronic myeloid leukemia in pregnancy is rare and its management poses a clinical challenge for physicians treating these patients. We report a 30-year-old woman with chronic myeloid leukemia who became pregnant twice successfully. Philadelphia-positive CML in its chronic phase was diagnosed at 16 weeks of her first gestation. At that time, she received no treatment throughout her pregnancy. At 38 weeks of gestation, a normal infant was delivered by cesarean section. At six weeks postpartum, the patient underwent imatinib mesylate therapy but she could not tolerate the treatment. The treatment was then changed to nilotinib at 400 mg orally b.i.d. Two years later, she became pregnant again while she was on nilotinib 200 mg b.i.d. The unplanned pregnancy was identified during her 7.4 weeks of gestation. Because the patient elected to continue her pregnancy, nilotinib was stopped immediately, and no further treatment was given until delivery. Neither obstetrical complications nor structural malformations in neonates in both pregnancies were observed. Both babies' growth and development have been normal. Although this experience is limited to a single patient, the success of this patient demonstrates that the management of chronic myeloid leukemia in pregnant women may be individualized based on the relative risks and benefits of the patient and fetus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To compare cervical length (CL) at 18-21 and 22-25 weeks` gestation in twin pregnancies in prediction of spontaneous preterm delivery and to examine cervical shortening. Methods: Retrospective cohort study of CL measured at 18-21 and 22-25 weeks` gestation in twin pregnancies. Results: Receiver operating characteristics (ROC) curve revealed area of 0.64 (95% CI 0.53-0.75) and 0.80 (95% CI 0.72-0.88) for measurements at 18-21 and 22-25 weeks, respectively (P <= 0.001). Sensitivities of 33.3% and 23% and negative predicting value (NPV) of 97.3% and 86.8% for delivery at <28 and <34 weeks gestation were reached for measurements at 18-21 weeks. Sensitivities of 71.4% and 38.2% and NPV of 99.1% and 91.4% for delivery at <28 and <34 weeks` gestation were reached for measurements at 22-25 weeks. Cervical length shortening analysis showed an area under ROC curve of 0.81 (95% CI 0.73-0.89) and best cut-off was at >= 2 mm/week. Sensitivities of 80% and 60.8% and NPV of 98.9% and 90.6% for delivery at <28 and <34 weeks gestation were reached. Conclusions: In twin gestations, assessment of CL at 22-25 weeks is better than assessment at 18-21 weeks to predict preterm delivery before 34 weeks. Cervical shortening at a rate of >= 2 mm/weeks between 18 and 25 weeks gestation was a good predictor of spontaneous preterm birth in this high-risk population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluate the distribution and variation of placental vascular indices according to gestational age and placental volume. From March to November 2007, three-dimensional (3D)-power Doppler ultrasound was performed in 295 normal pregnancies from 12 to 40 weeks of gestation. Using the same preestablished settings for all patients, power Doppler was applied to the placenta and placental Volume was obtained by the rotational technique (VOCAL(TM)). The 3D-power histogram was used to determine the placental vascular indices: vascularization index (VI), flow index (FI) and vascularization-flow index (VFI). The placental vascular indices were then plotted against gestational age and placental volume. All placental vascular indices showed constant distribution throughout gestation. A tendency for a reduction in placental vascular indices with increased placental volume was observed, but was only statistically significant when placental FI was considered (p < 0.05). All placental vascular indices estimated by 3D-power Doppler ultrasonography presented constant distribution throughout gestation, despite the increase in placental volume according to gestational age. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To determine accuracy of first trimester detection of single umbilical artery (SUA). Methods The number of vessels in the umbilical cord was examined in a prospective cohort of 779 singleton, low-risk, unselected pregnancies, in the first (11-13 weeks) and second (17-24 weeks) trimesters, using both power and color Doppler and after delivery, by placental histopathologic exam. Concordance between first and second trimester findings to postnatal diagnoses was compared by calculating kappa coefficients. Results There was medium concordance between the findings in the first trimester and the postnatal diagnoses (kappa = 0.52) and high concordance (kappa = 0.89) for the second trimester scan. Sensitivity, specificity, positive and negative predictive values for the findings in the first trimester were 57.1, 98.9, 50.0 and 99.2% and for the second trimester were 86.6, 99.9, 92.9 and 99.7%. Conclusion Sensitivity and positive predictive value of first trimester scan to identify an isolated SUA in a prospective unselected population was poor. Diagnosis of isolated SUA as well as a definitive judgment about the presence of associated anomalies would still require a scan in the second trimester. Copyright (C) 2011 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to establish normal ranges of blood flow velocities and indices in the fetal ductus venosus (DV) during the second half of normal pregnancy. A Doppler study of 60 healthy pregnant women without fetal pathologies was performed during the second half of pregnancy. The peak systolic velocity (PSV), peak diastolic velocity (PDV), maximum velocity during atrial contraction (VAC), peak systolic velocity/maximum velocity during atrial contraction (S/A ratio), pulsatility index for the vein (PIV), preload index (PLI) and velocity index for the vein (VIV) were calculated from the DV at 4-week intervals. A significant increase in PSV, PDV and VAC was observed from the 20-23(6/7) to the 28-31(6/7) weeks, with stabilization of values until the end of the pregnancy. On the other hand, the study showed a significant decrease for the S/A ratio, PIV, PLI and VIV from the 20-23(6/7) to the 28-31(6/7) weeks and remaining stable from then until term. (E-mail:dralemar@uol.com.br) (C) 2010 World Federation for Ultrasound in Medicine & Biology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Comparar dados pré-natais, dos partos e dos recém-nascidos de Campinas em 2001 e 2005. MÉTODOS: Estudo transversal que analisou 13.656 documentos do Sistema de Informações sobre Nascidos Vivos (Sinasc) de 2005, comparando-as aos resultados de 2001. Analisou-se o local de moradia e parto, idade materna, estado civil, escolaridade, ocupação, paridade, consultas de pré-natal, tipo de parto, duração da gestação e peso ao nascer. Para avaliar a associação entre as variáveis, utilizou-se o teste de qui-quadrado, sendo significante p<0,05. RESULTADOS: Os nascidos nos Distritos de Saúde (DS) com piores índices de condições de vida (ICV) diminuíram em relação a 2001. A taxa de adolescentes passou de 17,7% para 14,7%. Em 2001, 39,4% das mães trabalhavam e, em 2005, 42,9%. Quanto à presença de companheiro, 35,9 e 54,3% não o referiam em 2001 e 2005, respectivamente. A escolaridade passou de 37,8% de mães com até sete anos de estudo para 25,7%, com aumento das que estudaram entre oito e 11 anos e 12 anos ou mais. O comparecimento a mais de seis consultas no pré-natal passou de 74,4 para 86,6%. Houve aumento de cesáreas (54,9 para 60,3%) e de prematuridade (7,1 para 8,9%). Não houve alteração no perfil de peso ao nascimento. CONCLUSÕES: Verificou-se queda da paridade nos DS com piores ICV e no percentual de mães adolescentes. Elevou-se o número de trabalhadoras, mulheres sem companheiro, escolaridade e frequência ao pré-natal.