46 resultados para Monomer units


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pitzer`s equation for the excess Gibbs energy of aqueous solutions of low-molecular electrolytes is extended to aqueous solutions of polyelectrolytes. The model retains the original form of Pitzer`s model (combining a long-range term, based on the Debye-Huckel equation, with a short-range term similar to the virial equation where the second osmotic virial coefficient depends on the ionic strength). The extension consists of two parts: at first, it is assumed that a constant fraction of the monomer units of the polyelectrolyte is dissociated, i.e., that fraction does not depend on the concentration of the polyelectrolyte, and at second, a modified expression for the ionic strength (wherein each charged monomer group is taken into account individually) is introduced. This modification is to account for the presence of charged polyelectrolyte chains, which cannot be regarded as punctual charges. The resulting equation was used to correlate osmotic coefficient data of aqueous solutions of a single polyelectrolyte as well as of binary mixtures of a single polyelectrolyte and a salt with low-molecular weight. It was additionally applied to correlate liquid-liquid equilibrium data of some aqueous two-phase systems that might form when a polyelectrolyte and another hydrophilic but neutral polymer are simultaneously dissolved in water. A good agreement between the experimental data and the correlation result is observed for all investigated systems. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effect of pre-heating resin composite photo-cured with light-curing units (LCU) by FT-IR. Twenty specimens were made in a metallic mold (4 mm diameter x 2 mm thick) from composite resin-Tetric Ceram (R) (Ivoclar/Vivadent) at room temperature (25 degrees C) and pre heated to 37, 54, and 60 degrees C. The specimens were cured with halogen curing light (QTH) and light emitted by diodes (LED) during 40 s. Then, the specimens were pulverized, pressed with KBr and analyzed with FT-IR. The data were submitted to statistical analysis of variance and Kruskal-Wallis test. Study data showed no statistically significant difference to the degree of conversion for the different light curing units (QTH and LED) (p > 0.05). With the increase of temperature there was significant increase in the degree of conversion (p < 0.05). In this study were not found evidence that the light curing unit and temperature influenced the degree of conversion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the hardness of a dental composite resin submitted to temperature changes before photo-activation with two light-curing unite (LCUs). Five samples (4 mm in diameter and 2 mm in thickness) for each group were made with pre-cure temperatures of 37, 54, and 60A degrees C. The samples were photo-activated with a conventional quartz-tungsten-halogen (QTH) and blue LED LCUs during 40 s. The hardness Vickers test (VHN) was performed on the top and bottom surfaces of the samples. According to the interaction between light-curing unit and different pre-heating temperatures of composite resin, only the light-curing unit provided influences on the mean values of initial Vickers hardness. The light-curing unit based on blue LED showed hardness mean values more homogeneous between the top and bottom surfaces. The hardness mean values were not statistically significant difference for the pre-cure temperature used. According to these results, the pre-heating of the composite resin provide no influence on Vickers hardness mean values, however the blue LED showed a cure more homogeneous than QTH LCU.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A wide variety of opportunistic pathogens has been detected in the tubing supplying water to odontological equipment, in special in the biofilm lining of these tubes. Among these pathogens, Pseudomonas aeruginosa, one of the leading causes of nosocomial infections, is frequently found in water lines supplying dental units. In the present work, 160 samples of water, and 200 fomite samples from forty dental units were collected in the city of Barretos, State of São Paulo, Brazil and evaluated between January and July, 2005. Seventy-six P. aeruginosa strains, isolated from the dental environment (5 strains) and water system (71 strains), were tested for susceptibility to six antimicrobial drugs most frequently used against P. aeruginosa infections. Susceptibility to ciprofloxacin, followed by meropenem was the predominant profile. The need for effective means of reducing the microbial burden within dental unit water lines is emphasized, and the risk of exposure and cross-infection in dental practice, in special when caused by opportunistic pathogens like P. aeruginosa, are highlighted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to assess the prevalence of and risk factors for aminoglycoside-associated nephrotoxicity in intensive care units (ICUs), we evaluated 360 consecutive patients starting aminoglycoside therapy in an ICU. The patients had a baseline calculated glomerular filtration rate (cGFR) of ?30 ml/min/1.73 m2. Among these patients, 209 (58 per cent) developed aminoglycoside-associated nephrotoxicity (the acute kidney injury [AKI] group, which consisted of individuals with a decrease in cGFR of >20 per cent from the baseline cGFR), while 151 did not (non-AKI group). Both groups had similar baseline cGFRs. The AKI group developed a lower cGFR nadir (45 ± 27 versus 79 ± 39 ml/min/1.73 m2 for the non-AKI group; P < 0.001); was older (56 ± 18 years versus 52 ± 19 years for the non-AKI group; P = 0.033); had a higher prevalence of diabetes (19.6 per cent versus 9.3 per cent for the non-AKI group; P = 0.007); was more frequently treated with other nephrotoxic drugs (51 per cent versus 38 per cent for the non-AKI group; P = 0.024); used iodinated contrast more frequently (18 per cent versus 8 per cent for the non-AKI group; P = 0.0054); and showed a higher prevalence of hypotension (63 per cent versus 44 per cent for the non-AKI group; P = 0.0003), shock (56 per cent versus 31 per cent for the non-AKI group; P < 0.0001), and jaundice (19 per cent versus 8 per cent for the non-AKI group; P = 0.0036). The mortality rate was 44.5 per cent for the AKI group and 29.1 per cent for the non-AKI group (P = 0.0031). A logistic regression model identified as significant (P < 0.05) the following independent factors that affected aminoglycoside-associated nephrotoxicity: a baseline cGFR of <60 ml/min/1.73 m2 (odds ratio [OR], 0.42), diabetes (OR, 2.13), treatment with other nephrotoxins (OR, 1.61) or iodinated contrast (OR, 2.13), and hypotension (OR, 1.83). (To continue) In conclusion, AKI was frequent among ICU patients receiving an aminoglycoside, and it was associated with a high rate of mortality. The presence of diabetes or hypotension and the use of other nephrotoxic drugs and iodinated contrast were independent risk factors for the development of aminoglycoside-associated nephrotoxicity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to develop the concept of the dignified death of children in Brazilian pediatric intensive care units (PICUs). The Hybrid Model for Concept Development was used to develop a conceptual structure of dignified death in PICUs in an attempt to define the concept. The fieldwork study was carried out by means of in-depth interviews with nine nurses and seven physicians working in PICUs. Not unexpectedly, the concept of dignified death was found to be a complex phenomenon involving aspects related to decisions made by the multidisciplinary team as well as those related to care of the child and the family. Knowledge of the concept`s dimensions can promote reflection on the part of healthcare professionals regarding the values and beliefs underlying their conduct in end-of-life situations. Our hope is that this study may contribute to theoretic and methodological development in the area of end-of-life care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The kinetics of the solution free radical polymerization of N-vinylcaprolactam, in 1,4-dioxane and under various polymerization conditions was studied. Azobisisobutyronitrile and 3-mercaptopropionic acid were used as initiator and as chain transfer agent (CTA), respectively. The influence of monomer and initiator concentrations and polymerization temperature on the rate of polymerizations (R(p)) was investigated. In general, high conversions were obtained. The order with respect to initiator was consistent with the classical kinetic rate equation, while the order with respect to the monomer was greater than unity. The overall activation energy of 53.6 kJ mol(-1) was obtained in the temperature range 60-80 degrees C. The decreasing of the absolute molecular weights when increasing the CIA concentration was confirmed by GPC/SEC/LALS analyses. It was confirmed by UV-visible analyses the effect of molecular weights on the lower critical solution temperature of the polymers. It was also verified that the addition of the CTA influenced the kinetic of the polymerizations. (C) 2010 Wiley Periodicals, Inc. J Appl Polym Sci 118: 229-240, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate drug interaction software programs and determine their accuracy in identifying drug-drug interactions that may occur in intensive care units. Setting The study was developed in Brazil. Method Drug interaction software programs were identified through a bibliographic search in PUBMED and in LILACS (database related to the health sciences published in Latin American and Caribbean countries). The programs` sensitivity, specificity, and positive and negative predictive values were determined to assess their accuracy in detecting drug-drug interactions. The accuracy of the software programs identified was determined using 100 clinically important interactions and 100 clinically unimportant ones. Stockley`s Drug Interactions 8th edition was employed as the gold standard in the identification of drug-drug interaction. Main outcome Sensitivity, specificity, positive and negative predictive values. Results The programs studied were: Drug Interaction Checker (DIC), Drug-Reax (DR), and Lexi-Interact (LI). DR displayed the highest sensitivity (0.88) and DIC showed the lowest (0.69). A close similarity was observed among the programs regarding specificity (0.88-0.92) and positive predictive values (0.88-0.89). The DIC had the lowest negative predictive value (0.75) and DR the highest (0.91). Conclusion The DR and LI programs displayed appropriate sensitivity and specificity for identifying drug-drug interactions of interest in intensive care units. Drug interaction software programs help pharmacists and health care teams in the prevention and recognition of drug-drug interactions and optimize safety and quality of care delivered in intensive care units.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Guidelines for red blood cell (RBC) transfusions exist; however, transfusion practices vary among centers. This study aimed to analyze transfusion practices and the impact of patients and institutional characteristics on the indications of RBC transfusions in preterm infants. STUDY DESIGN AND METHODS: RBC transfusion practices were investigated in a multicenter prospective cohort of preterm infants with a birth weight of less than 1500 g born at eight public university neonatal intensive care units of the Brazilian Network on Neonatal Research. Variables associated with any RBC transfusions were analyzed by logistic regression analysis. RESULTS: Of 952 very-low-birth-weight infants, 532 (55.9%) received at least one RBC transfusion. The percentages of transfused neonates were 48.9, 54.5, 56.0, 61.2, 56.3, 47.8, 75.4, and 44.7%, respectively, for Centers 1 through 8. The number of transfusions during the first 28 days of life was higher in Center 4 and 7 than in other centers. After 28 days, the number of transfusions decreased, except for Center 7. Multivariate logistic regression analysis showed higher likelihood of transfusion in infants with late onset sepsis (odds ratio [OR], 2.8; 95% confidence interval [CI], 1.8-4.4), intraventricular hemorrhage (OR, 9.4; 95% CI, 3.3-26.8), intubation at birth (OR, 1.7; 95% CI, 1.0-2.8), need for umbilical catheter (OR, 2.4; 95% CI, 1.3-4.4), days on mechanical ventilation (OR, 1.1; 95% CI, 1.0-1.2), oxygen therapy (OR, 1.1; 95% CI, 1.0-1.1), parenteral nutrition (OR, 1.1; 95% CI, 1.0-1.1), and birth center (p < 0.001). CONCLUSIONS: The need of RBC transfusions in very-low-birth-weight preterm infants was associated with clinical conditions and birth center. The distribution of the number of transfusions during hospital stay may be used as a measure of neonatal care quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simulation of irrigated Thanzania grass growth based on photothermal units, nitrogen fertilization and water availability. The mathematical model to predict the forage yield using photothennal units was utilized with success in Elephant grass, Thanzania and Brachiaria niziziensis in the absence of water stress and nitrogen stress. The aim of this study was to propose models to estimate the forage yield of Thanzania grass under different irrigation (25, 50,75, 100 e 125% of ETc) and nitrogen level in various regions of Brazil. As such, models were developed to estimate the dry matter production of Panicum maximum Jacq. frass cv Thanzania in different irrigation and nitrogen levels, using photothermal units. The models were adjusted to doses of 0, 30, 60, 110 and 270 kg of N ha(-1), doses were divided in applications after each evaluation, with a rest cycle of 35 days. The adjusted model presented good performance in predicting dry matter production of Thanzania grass, with r(2) = 0.9999. The results made it possible to verify that the proposed model can be used to predict forage production in different regions of Brazil. It can be estimated, with good precision. The production of Thanzania grass dry matter can be accurately estimated in specific places (in function of latitude and time of year), with the maximum and minimum temperature values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dolastatin units were synthesized from the 1,2-addition reactions of potassium allyl or crotyltrifluoroborate salts to aldehyde derivatives from natural amino acids. The reactions were carried out in presence of a phase-transfer catalyst in a biphasic medium at room temperature and excellent yields (>89-93%) and stereoselective (>90:10 to 98:2) were obtained. The dolastatin units 8 and 14a-b were obtained after three steps in good overall yields (50-62%). (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports on the bimolecular sensitization of nitric oxide release from cis-[Ru(bpy)(2)(iso)-NO](PF(6))(3) (1) (iso = isoquinoline and bpy = 2,2`- bipyridine) by irradiating the MLCT transition of the chloro analog cis-[Ru(bpy) 2(iso) Cl] PF6 (2). The compounds displayed peaks in the ESI-MS spectra at m/z 749.1 and m/z 578.1 ascribed, respectively, to ([1(NO(o))-2PF(6)center dot CH(3)OH](2+)) and ([2-PF(6)](+)). In the cyclic voltammograms, the nitrosyl complex presented two redox waves related to the NO ligand at 0.48 and -0.37 V (versus Ag/AgCl, NO(+/0/-1) processes), while the sensitizer showed two reversible waves at 0.79 and -1.46 V (versus Ag/AgCl, Ru(2+/3+) and bpy(0/-1), respectively). The most important feature of this system is that the nitrosyl compound does not have significant absorption in the visible region, while the sensitizer has an intense band centered at 496 nm. The irradiation of an equimolar mixture of the two compounds in an ethanol: water solution (v: v) with light of lambda > 500 nm leads to NO release, as probed by amperometric measurements. The variational method was applied, showing that the two compounds self-assembly in solution with a 1: 1 stoichiometry. Fluorescence spectra acquired at 77 K provided the E(0-0) for the system and, from the thermodynamic cycle it was estimated that the photoinduced electron transfer between the species has a Delta G value of -1.59 eV. (C) 2011 Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: to determine the relationship between age and in-hospital mortality of elderly patients, admitted to ICU, requiring and not requiring invasive ventilatory support. Design: prospective observational cohort study conducted over a period of 11 months. Setting: medical-surgical ICU at a Brazilian university hospital. Subjects: a total of 840 patients aged 55 years and older were admitted to ICU. Methods: in-hospital death rates for patients requiring and not requiring invasive ventilatory support were compared across three successive age intervals (55-64; 65-74 and 75 or more years), adjusting for severity of illness using the Acute Physiologic Score. Results: age was strongly correlated with mortality among the invasively ventilated subgroup of patients and the multivariate adjusted odds ratios increased progressively with every age increment (OR = 1.60, 95% CI = 1.01-2.54 for 65-74 years old and OR = 2.68, 95% CI = 1.58-4.56 for >= 75 years). For the patients not submitted to invasive ventilatory support, age was not independently associated with in-hospital mortality (OR = 2.28, 95% CI = 0.99-5.25 for 65-74 years old and OR = 1.95, 95% CI = 0.82-4.62 for >= 75 years old). Conclusions: the combination of age and invasive mechanical ventilation is strongly associated with in-hospital mortality. Age should not be considered as a factor related to in-hospital mortality of elderly patients not requiring invasive ventilatory support in ICU.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Candidemia is associated with high morbidity and mortality resulting in significant increases in the length of patients` hospitalization and in healthcare costs. Critically ill patients are at particular risk for candidemia because of their debilitated condition and frequent need for invasive procedures. The aim of this study was to characterize the incidence and epidemiology of candidemia over a seven-year period in intensive care units (ICUs) and the use of fluconazole and caspofungin in a large university-affiliated hospital. All cases of candidemia were identified by surveillance, using the Centers for Diseases Control and Prevention criteria. Demographic variables, use of antifungal (fluconazole and caspofungin) and patient outcomes were evaluated. The 2 test for linear trend was employed to evaluate the distribution of Candida spp. and the use of fluconazole and caspofungin by defined daily dose (DDD) per 1,000 patients-days during the study period. One hundred and eight episodes of candidemia were identified. The overall incidence of candidemia (P=0.20) and incidence of non-Candida albicans Candida infections (P=0.32) remained stable over the study period and ranged from 0.3-0.9 episodes per 1,000 catheter-days and 0.39-0.83 episodes per 1,000 patients-days. However, the use of fluconazole and caspofungin increased significantly (P0.001). While there were no reports of the use of fluconazole for prophylaxis in 1999, its use for this purpose increased from 3% in 2000 to 7.0% (P=0.07) in 2006. C. albicans was the most frequent specie isolated and burns and cancer were the most frequent underlying conditions. The overall mortality was 76%. There was no difference between C. albicans and non-C. albicans Candida infections when the crude and 14-day mortality rates were compared. Our data demonstrated that C. albicans is still the most frequent species causing candidemia in our intensive care units. Our rates of candidemia are lower than those reported from the region and similar to American and European hospitals. Although the incidence of blood stream infections (BSI) and candidemia remained stable, the use of fluconazole and caspofungin increased significantly over the years included in this study but had no impact on the incidence of infections caused by non-C. albicans Candida species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cervical cancer is a serious public health problem in women in developing countries because of absence or ineffectiveness of screening programs. Several biases to access medical care and inequity of public health system in a continental country like Brazil limit the implementation of adequate programs to appropriately prevent the cervical cancer. Therefore, the aim of this study was to evaluate the results of applying the mobile unit (MU) for cervical cancer screening. From May 2003 to May 2004, a cervical cancer screening was offered to women aged 20-69 years, residing in 19 municipal districts of the Barretos county region, in Sao Paulo. Out of the 9,560 examination available, 2,964 (31%) women underwent screening. The medium distance traveled by the MU was 45 km. The medium time spent by women in the MU for completion of the questionnaire and doing the exam was 20 minutes. It was observed that 17.0% of women screened had never had the test or had not had it repeated within the last 3 years. The negative response was more common among women aged 20 to 29 years and 60 to 69 years and among women with less schooling and lower socio-economic income (P < 0.05). MU can significantly overcome the chronic deficiency of public health system accessibility offering opportunity to these women to participate in screening programs. Diagn. Cytopathol. 2010;38:727-730. (C) 2009 Wiley-Liss, Inc.