6 resultados para foot placement variability
em WestminsterResearch - UK
Resumo:
This paper presents the design analysis of novel tunable narrow-band bandpass sigma-delta modulators, that can achieve concurrent multiple noise-shaping for multi-tone input signals. This approach utilises conventional comb filters in conjunction with FIR, or allpass IIR fractional delay filters, to deliver the desired nulls for the quantisation noise transfer function. Detailed simulation results show that FIR fractional delay comb filter based sigma-delta modulators tune accurately to most centre frequencies, but suffer from degraded resolution at frequencies close to Nyquist. However, superior accuracies are obtained from their allpass IIR fractional delay counterpart at the expense of a slight shift in noise-shaping bands at very high frequencies.
Resumo:
The management of wound bioburden has previously been evaluated using various antimicrobial wound dressings on bacterial pathogens isolated from various wounds. In this present study, the antimicrobial effect of silver-impregnated dressings (Acticoat and Silvercel) and honey-impregnated dressing (Medihoney™ Apinate) on both planktonic bacteria and quasi-biofilms by Staphylococcus aureus and Proteus mirabilis were assessed using a 6-well plate and standard agar technique. In the 6-well plate assay, a bacterial suspension of 108 colony forming unit (CFU)/mL was inoculated on each dressing in excess Luria-Bertani broth and incubated at 35 – 37°C for 30 and 60 minutes and 24 hours. After each incubation time, bacteria were recovered in sodium thioglycolate solution (STS) and the CFU/mL determined on LB agar. Dressings were cut into circular shapes (2cm diameter and placed on Mueller Hinton agar plates pre-inoculated with bacterial suspensions to determine their zones of inhibition (ZOI) after 24 hours incubation. None of the dressings was effective to significantly inhibit bacterial growth or biofilm formation at all the times tested. Acticoat and Medihoney™ Apinate produced ZOIs between 1.5 – 15 mm against both Staphylococcus aureus and Proteus mirabilis. It is possible that, dressings augmented with antibiotics can significantly reduce quasi-biofilms on standard agar.
Resumo:
The impact of biofilm in the effective control of wound microbiome is an ongoing dilemma which has seen the use of different treatment strategies. The effects of wound dressings and antibiotics on both planktonic bacteria and biofilms have been separately evaluated in previous studies. In this current study, the combined antimicrobial effects of some selected wound dressings (silver-impregnated: Acticoat and Silvercel; and honey-impregnated: Medihoney™ Apinate) and antibiotics (ceftazdime and levofloxacin) on Klebsiella pneumoniae and Proteus mirabilis in their quasi-biofilm state were assessed using zone of inhibition (ZOI) test. Before the addition of the wound dressings, bacterial suspension of 108 colony forming units per mL and different concentrations of ceftazidime and levofloxacin (256, 512, 1024 and 5120µg/mL) of a final volume of 1mL were inoculated on Mueller Hinton agar and allowed to dry. Wound dressings cut into circular shapes (2cm diameter) were aseptically placed on the agar plates and incubated at 35 – 37°C for 24 hours. ZOIs associated with Acticoat, Silvercel and Medihoney™ Apinate dressings were compared with that of Atrauman (non-medicated control) dressing. All three dressings showed significant (p < 0.05) biofilm-inhibiting activity against both bacteria at antibiotic concentrations of 1024 and 5120µg/mL with ZOI between 17.5 and 35mm.
Resumo:
Background: The increasing resistance of Gram-negative bacteria isolated from nosocomial infections and chronic wounds, such as diabetic foot ulcers has renewed research interests in the use of polymyxins in the treatment of multidrug resistant infections. The added resistance conferred by biofilm development in such infections and the absence of novel antibiotics presuppose that polymyxins are the likely drugs of choice in spite of their nephrotoxicity. The effects of PMB and PMBN have been previously assessed on planktonic bacteria isolated from various infections. Methods: This current study assessed the synergy between a PMB/PMBN and two antibiotics (ceftazidime and levofloxacin) in an attempt to develop a strategy for biofilm disruption using the Minimum Biofilm Eradication Concentration Physiology and Genetic assay (MBEC™ P & G, Innovotech Inc, Edmonton, Alberta, Canada) according to manufacturer’s instructions. Klebsiella pneumoniae (K. pneumoniae) and Proteus mirabilis (P. mirabilis) biofilms of initial broth suspensions of 108 colony forming units per mL, cultivated on the pegs of the MBEC device were challenged with 5120 µg/mL of both ceftazidime and levofloxacin in a ten-fold dilution assay and in the presence of 100 and 500 µg/mL PMB and PMBN. Results: From table of results (Table 1), it can be deduced that both ceftazidime and levofloxacin are very effective in inhibiting biofilm development (as shown by percentage inhibition (PI)) when augmented with PMB and PMBN. This is about 100-fold increase in efficacy when compared to the antibiotics used on their own. The percentage reduction (PR) in biofilm was also increased considerably when PMB and PMBN concentrations were increased to 500 µg/mL. PMB was more effective than its less antibacterial derivative PMBN. Levofloxacin was also found to be more effective than ceftazidime when combined with both PMB and PMBN due to its enhanced cell-membrane permeability and as an anti-DNA replication uncoupling agent. Conclusion: The above results indicate that the synergy between antibiotics and cell membrane permeabilising agents may provide alternate strategies towards biofilm eradication
Resumo:
Objective: The Finometer (FMS, Finapres Measurement Systems, Amsterdam) records the beat-to-beat finger pulse contour and has been recommended for research studies assessing shortterm changes of blood pressure and its variability. Variability measured in the frequency domain using spectral analysis requires that the impact of breathing be restricted to high frequency spectra (> 0.15 Hz) so data from participants needs to be excluded when the breathing impact occurs in the low frequency spectra (0.04 - 0.15 Hz). This study tested whether breathing frequency can be estimated from standard Finometer recordings using either stroke volume oscillation frequency or spectral stroke volume variability maximum scores. Methods: 22 healthy volunteers were tested for 270s in the supine and upright positions. Finometer recorded the finger pulse contour and a respiratory transducer recorded breathing. Stoke volume oscillation frequency was calculated manually while the stroke volume spectral maximums were obtained using the software Cardiovascular Parameter Analysis (Nevrokard Kiauta, Izola, Slovenia). These estimates were compared to the breathing frequency using the Bland-Altman procedures. Results: Stroke volume oscillation frequency estimated breathing frequency to <±10% 95% levels of agreement in both supine (-7.7 to 7.0%) and upright (-6.7 to 5.4%) postures. Stroke volume variability maximum scores did not accurately estimate breathing frequency. Conclusions: Breathing frequency can be accurately derived from standard Finometer recordings using stroke volume oscillations for healthy individuals in both supine and upright postures. The Finometer can function as a standalone instrument in blood pressure variability studies and does not require support equipment to determine breathing frequency.
Resumo:
The quantity of blood arriving at the left side of the heart oscillates throughout the breathing cycle due to the mechanics of breathing. Neurally regulated fluctuations in the length of the heart period act to dampen oscillations of the left ventricular stroke volume entering the aorta. We have reported that stroke volume oscillations but not spectral frequency variability stroke volume measures can be used to estimate the breathing frequency. This study investigated with the same recordings whether heart period oscillations or spectral heart rate variability measures could function as estimators of breathing frequency. Continuous 270 s cardiovascular recordings were obtained from 22 healthy adult volunteers in the supine and upright postures. Breathing was recorded simultaneously. Breathing frequency and heart period oscillation frequency were calculated manually, while heart rate variability spectral maximums were obtained using heart rate variability software. These estimates were compared to the breathing frequency using the Bland–Altman agreement procedure. Estimates were required to be \±10% (95% levels of agreement). The 95% levels of agreement measures for the heart period oscillation frequency (supine: -27.7 to 52.0%, upright: -37.8 to 45.9%) and the heart rate variability spectral maximum estimates (supine: -48.7 to 26.5% and -56.4 to 62.7%, upright: -37.8 to 39.3%) exceeded 10%. Multiple heart period oscillations were observed to occur during breathing cycles. Both respiratory and non-respiratory sinus arrhythmia was observed amongst healthy adults. This observation at least partly explains why heart period parameters and heart rate variability parameters are not reliable estimators of breathing frequency. In determining the validity of spectral heart rate variability measurements we suggest that it is the position of the spectral peaks and not the breathing