3 resultados para User Evaluation

em WestminsterResearch - UK


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Adequate user authentication is a persistent problem, particularly with mobile devices, which tend to be highly personal and at the fringes of an organisation's influence. Yet these devices are being used increasingly in various business settings, where they pose a risk to security and privacy, not only from sensitive information they may contain, but also from the means they typically offer to access such information over wireless networks. User authentication is the first line of defence for a mobile device that falls into the hands of an unauthorised user. However, motivating users to enable simple password mechanisms and periodically update their authentication information is difficult at best. This paper examines some of the issues relating to the use of biometrics as a viable method of authentication on mobile wireless devices. It is also a critical analysis of some of the techniques currently employed and where appropriate, suggests novel hybrid ways in which they could be improved or modified. Both biometric technology and wireless setting based constraints that determine the feasibility and the performance of the authentication feature are specified. Some well known biometric technologies are briefly reviewed and their feasibility for wireless and mobile use is reviewed. Furthermore, a number of quantitative and qualitative parameters for evaluation are also presented. Biometric technologies are continuously advancing toward commercial implementation in wireless devices. When carefully designed and implemented, the advantage of biometric authentication arises mainly from increased convenience and coexistent improved security.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper addresses issues related to the design of a graphical query mechanism that can act as an interface to any object-oriented database system (OODBS), in general, and the object model of ODMG 2.0, in particular. In the paper a brief literature survey of related work is given, and an analysis methodology that allows the evaluation of such languages is proposed. Moreover, the user's view level of a new graphical query language, namely GOQL (Graphical Object Query Language), for ODMG 2.0 is presented. The user's view level provides a graphical schema that does not contain any of the perplexing details of an object-oriented database schema, and it also provides a foundation for a graphical interface that can support ad-hoc queries for object-oriented database applications. We illustrate, using an example, the user's view level of GOQL

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The inherent analogue nature of medical ultrasound signals in conjunction with the abundant merits provided by digital image acquisition, together with the increasing use of relatively simple front-end circuitries, have created considerable demand for single-bit  beamformers in digital ultrasound imaging systems. Furthermore, the increasing need to design lightweight ultrasound systems with low power consumption and low noise, provide ample justification for development and innovation in the use of single-bit  beamformers in ultrasound imaging systems. The overall aim of this research program is to investigate, establish, develop and confirm through a combination of theoretical analysis and detailed simulations, that utilize raw phantom data sets, suitable techniques for the design of simple-to-implement hardware efficient  digital ultrasound beamformers to address the requirements for 3D scanners with large channel counts, as well as portable and lightweight ultrasound scanners for point-of-care applications and intravascular imaging systems. In addition, the stability boundaries of higher-order High-Pass (HP) and Band-Pass (BP) Σ−Δ modulators for single- and dual- sinusoidal inputs are determined using quasi-linear modeling together with the describing-function method, to more accurately model the  modulator quantizer. The theoretical results are shown to be in good agreement with the simulation results for a variety of input amplitudes, bandwidths, and modulator orders. The proposed mathematical models of the quantizer will immensely help speed up the design of higher order HP and BP Σ−Δ modulators to be applicable for digital ultrasound beamformers. Finally, a user friendly design and performance evaluation tool for LP, BP and HP  modulators is developed. This toolbox, which uses various design methodologies and covers an assortment of  modulators topologies, is intended to accelerate the design process and evaluation of  modulators. This design tool is further developed to enable the design, analysis and evaluation of  beamformer structures including the noise analyses of the final B-scan images. Thus, this tool will allow researchers and practitioners to design and verify different reconstruction filters and analyze the results directly on the B-scan ultrasound images thereby saving considerable time and effort.