4 resultados para Parliamentary technology assessment
em WestminsterResearch - UK
Resumo:
The cortisol awakening response (CAR) is typically measured in the domestic setting. Moderate sample timing inaccuracy has been shown to result in erroneous CAR estimates and such inaccuracy has been shown partially to explain inconsistency in the CAR literature. The need for more reliable measurement of the CAR has recently been highlighted in expert consensus guidelines where it was pointed out that less than 6% of published studies provided electronic-monitoring of saliva sampling time in the post-awakening period. Analyses of a merged data-set of published studies from our laboratory are presented. To qualify for selection, both time of awakening and collection of the first sample must have been verified by electronic-monitoring and sampling commenced within 15 min of awakening. Participants (n = 128) were young (median age of 20 years) and healthy. Cortisol values were determined in the 45 min post-awakening period on 215 sampling days. On 127 days, delay between verified awakening and collection of the first sample was less than 3 min (‘no delay’ group); on 45 days there was a delay of 4–6 min (‘short delay’ group); on 43 days the delay was 7–15 min (‘moderate delay’ group). Cortisol values for verified sampling times accurately mapped on to the typical post-awakening cortisol growth curve, regardless of whether sampling deviated from desired protocol timings. This provides support for incorporating rather than excluding delayed data (up to 15 min) in CAR analyses. For this population the fitted cortisol growth curve equation predicted a mean cortisol awakening level of 6 nmols/l (±1 for 95% CI) and a mean CAR rise of 6 nmols/l (±2 for 95% CI). We also modelled the relationship between real delay and CAR magnitude, when the CAR is calculated erroneously by incorrectly assuming adherence to protocol time. Findings supported a curvilinear hypothesis in relation to effects of sample delay on the CAR. Short delays of 4–6 min between awakening and commencement of saliva sampling resulted an overestimated CAR. Moderate delays of 7–15 min were associated with an underestimated CAR. Findings emphasize the need to employ electronic-monitoring of sampling accuracy when measuring the CAR in the domestic setting.
Resumo:
The impact of biofilm in the effective control of wound microbiome is an ongoing dilemma which has seen the use of different treatment strategies. The effects of wound dressings and antibiotics on both planktonic bacteria and biofilms have been separately evaluated in previous studies. In this current study, the combined antimicrobial effects of some selected wound dressings (silver-impregnated: Acticoat and Silvercel; and honey-impregnated: Medihoney™ Apinate) and antibiotics (ceftazdime and levofloxacin) on Klebsiella pneumoniae and Proteus mirabilis in their quasi-biofilm state were assessed using zone of inhibition (ZOI) test. Before the addition of the wound dressings, bacterial suspension of 108 colony forming units per mL and different concentrations of ceftazidime and levofloxacin (256, 512, 1024 and 5120µg/mL) of a final volume of 1mL were inoculated on Mueller Hinton agar and allowed to dry. Wound dressings cut into circular shapes (2cm diameter) were aseptically placed on the agar plates and incubated at 35 – 37°C for 24 hours. ZOIs associated with Acticoat, Silvercel and Medihoney™ Apinate dressings were compared with that of Atrauman (non-medicated control) dressing. All three dressings showed significant (p < 0.05) biofilm-inhibiting activity against both bacteria at antibiotic concentrations of 1024 and 5120µg/mL with ZOI between 17.5 and 35mm.
Resumo:
Background: The increasing resistance of Gram-negative bacteria isolated from nosocomial infections and chronic wounds, such as diabetic foot ulcers has renewed research interests in the use of polymyxins in the treatment of multidrug resistant infections. The added resistance conferred by biofilm development in such infections and the absence of novel antibiotics presuppose that polymyxins are the likely drugs of choice in spite of their nephrotoxicity. The effects of PMB and PMBN have been previously assessed on planktonic bacteria isolated from various infections. Methods: This current study assessed the synergy between a PMB/PMBN and two antibiotics (ceftazidime and levofloxacin) in an attempt to develop a strategy for biofilm disruption using the Minimum Biofilm Eradication Concentration Physiology and Genetic assay (MBEC™ P & G, Innovotech Inc, Edmonton, Alberta, Canada) according to manufacturer’s instructions. Klebsiella pneumoniae (K. pneumoniae) and Proteus mirabilis (P. mirabilis) biofilms of initial broth suspensions of 108 colony forming units per mL, cultivated on the pegs of the MBEC device were challenged with 5120 µg/mL of both ceftazidime and levofloxacin in a ten-fold dilution assay and in the presence of 100 and 500 µg/mL PMB and PMBN. Results: From table of results (Table 1), it can be deduced that both ceftazidime and levofloxacin are very effective in inhibiting biofilm development (as shown by percentage inhibition (PI)) when augmented with PMB and PMBN. This is about 100-fold increase in efficacy when compared to the antibiotics used on their own. The percentage reduction (PR) in biofilm was also increased considerably when PMB and PMBN concentrations were increased to 500 µg/mL. PMB was more effective than its less antibacterial derivative PMBN. Levofloxacin was also found to be more effective than ceftazidime when combined with both PMB and PMBN due to its enhanced cell-membrane permeability and as an anti-DNA replication uncoupling agent. Conclusion: The above results indicate that the synergy between antibiotics and cell membrane permeabilising agents may provide alternate strategies towards biofilm eradication
Resumo:
Assessing the subjective quality of processed images through an objective quality metric is a key issue in multimedia processing and transmission. In some scenarios, it is also important to evaluate the quality of the received images with minimal reference to the transmitted ones. For instance, for closed-loop optimisation of image and video transmission, the quality measure can be evaluated at the receiver and provided as feedback information to the system controller. The original images - prior to compression and transmission - are not usually available at the receiver side, and it is important to rely at the receiver side on an objective quality metric that does not need reference or needs minimal reference to the original images. The observation that the human eye is very sensitive to edge and contour information of an image underpins the proposal of our reduced reference (RR) quality metric, which compares edge information between the distorted and the original image. Results highlight that the metric correlates well with subjective observations, also in comparison with commonly used full-reference metrics and with a state-of-the-art reduced reference metric. © 2012 ICST Institute for Computer Science, Social Informatics and Telecommunications Engineering.