4 resultados para Automatic checkout equipment

em WestminsterResearch - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Grid Execution Management for Legacy Code Architecture (GEMLCA) enables exposing legacy applications as Grid services without re-engineering the code, or even requiring access to the source files. The integration of current GT3 and GT4 based GEMLCA implementations with the P-GRADE Grid portal allows the creation, execution and visualisation of complex Grid workflows composed of legacy and nonlegacy components. However, the deployment of legacy codes and mapping their execution to Grid resources is currently done manually. This paper outlines how GEMLCA can be extended with automatic service deployment, brokering, and information system support. A conceptual architecture for an Automatic Deployment Service (ADS) and for an x-Service Interoperability Layer (XSILA) are introduced explaining how these mechanisms support desired features in future releases of GEMLCA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The Finometer (FMS, Finapres Measurement Systems, Amsterdam) records the beat-to-beat finger pulse contour and has been recommended for research studies assessing shortterm changes of blood pressure and its variability. Variability measured in the frequency domain using spectral analysis requires that the impact of breathing be restricted to high frequency spectra (> 0.15 Hz) so data from participants needs to be excluded when the breathing impact occurs in the low frequency spectra (0.04 - 0.15 Hz). This study tested whether breathing frequency can be estimated from standard Finometer recordings using either stroke volume oscillation frequency or spectral stroke volume variability maximum scores. Methods: 22 healthy volunteers were tested for 270s in the supine and upright positions. Finometer recorded the finger pulse contour and a respiratory transducer recorded breathing. Stoke volume oscillation frequency was calculated manually while the stroke volume spectral maximums were obtained using the software Cardiovascular Parameter Analysis (Nevrokard Kiauta, Izola, Slovenia). These estimates were compared to the breathing frequency using the Bland-Altman procedures. Results: Stroke volume oscillation frequency estimated breathing frequency to <±10% 95% levels of agreement in both supine (-7.7 to 7.0%) and upright (-6.7 to 5.4%) postures. Stroke volume variability maximum scores did not accurately estimate breathing frequency. Conclusions: Breathing frequency can be accurately derived from standard Finometer recordings using stroke volume oscillations for healthy individuals in both supine and upright postures. The Finometer can function as a standalone instrument in blood pressure variability studies and does not require support equipment to determine breathing frequency.