4 resultados para Automated quantification

em WestminsterResearch - UK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gametocytes of the malaria parasite Plasmodium falciparum are highly resistant to antimalarial drugs. Its presence in the blood can be detected even after a successful malaria treatment. This paper explains a modified Annular Ring Ratio method which successfully locates and differentiates gametocytes of P. falciparum species in thin blood film images. The method can be used as an efficient tool for gametocyte detection for post-treatment malaria diagnosis. It also identifies the presence of any White Blood Cells (WBCs) in the image, and discards other artifacts and non infected cells. It utilizes the information based on structure, color and geometry of the cells and does not require any segmentation or non-illumination correction techniques that are commonly used for cell detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Central obesity is the hallmark of a number of non-inheritable disorders. The advent of imaging techniques such asMRI has allowed for a fast and accurate assessment of body fat content and distribution. However, image analysis continues to be one of the major obstacles to the use of MRI in large-scale studies. In this study we assess the validity of the recently proposed fat–muscle quantitation system (AMRATM Profiler) for the quantification of intra-abdominal adipose tissue (IAAT) and abdominal subcutaneous adipose tissue (ASAT) from abdominal MR images. Abdominal MR images were acquired from 23 volunteers with a broad range of BMIs and analysed using sliceOmatic, the current gold-standard, and the AMRATM Profiler based on a non-rigid image registration of a library of segmented atlases. The results show that there was a highly significant correlation between the fat volumes generated by the two analysis methods, (Pearson correlation r = 0.97, p < 0.001), with the AMRATM Profiler analysis being significantly faster (~3 min) than the conventional sliceOmatic approach (~40 min). There was also excellent agreement between the methods for the quantification of IAAT (AMRA 4.73 ± 1.99 versus sliceOmatic 4.73 ± 1.75 l, p = 0.97). For the AMRATM Profiler analysis, the intra-observer coefficient of variation was 1.6% for IAAT and 1.1% for ASAT, the inter-observer coefficient of variationwas 1.4%for IAAT and 1.2%for ASAT, the intra-observer correlationwas 0.998 for IAAT and 0.999 for ASAT, and the inter-observer correlation was 0.999 for both IAAT and ASAT. These results indicate that precise and accurate measures of body fat content and distribution can be obtained in a fast and reliable form by the AMRATM Profiler, opening up the possibility of large-scale human phenotypic studies.