10 resultados para 671300 Communication Equipment
em WestminsterResearch - UK
Resumo:
This work addresses the joint compensation of IQimbalances and carrier phase synchronization errors of zero- IF receivers. The compensation scheme based on blind-source separation which provides simple yet potent means to jointly compensate for these errors independent of modulation format and constellation size used. The low-complexity of the algorithm makes it a suitable option for real-time deployment as well as practical for integration into monolithic receiver designs.
Resumo:
This paper provides an overview of the sources and effects of the RF impairments limiting and rendering the performance of the future wireless communication transceivers costly as well as hindering their wide-spread use in commercial products. As transmission bandwidths and carrier frequencies increase effect of these impairments worsen. This paper studies and presents analytical evaluations of the performance degradation due to the RF impairments in terms of bit-error-rate and image rejection ratio. The paper also give highlights of the various aspects of the research carried out in mitigating the effects of these impairments primarily in the digital signal processing domain at the baseband as well as providing low-complexity hardware implementations of such algorithms incorporating a number of power and area saving techniques.
Resumo:
A compact highly linear microstrip dual - mode optically switchable filter and a reconfigurable power amplifier are presented. The key characteristics of the dual - mode switchable filter are investigated and described. A second order filter design procedure is outlined to facilitate the realisation of Butterworth and Chebyshev functions. The proposed filter was built and tested with an optical switch, which comprised of a silicon dice acti vated using near infrared light. The measured and simulated results are in good agreement. The measured insertion loss in the ON state was 3.0 dB the isolation in the OFF state was 45 dB at the centre frequency. An evaluation of filter distortion is presen ted for digitally modulated M - QAM and M - QAM OFDM singals.
Resumo:
This article reports on a study that examined the personal employment paths of six international academics at a British university. To complement previous accounts of difficult migration, it focuses on the successful experiences of such academics, in particular how proficiency in English facilitated their move into employment in higher education (HE), and the linguistic competences and communication strategies they deploy in their daily activities. The article identifies key factors that have facilitated to their academic achievements and contributes to the understanding of the benefits and consequences of skilled migration. In conclusion, it suggests workplace pedagogy and policy responses that could facilitate other international academics' successful experiences in the UK HE sector.
Resumo:
Objective: The Finometer (FMS, Finapres Measurement Systems, Amsterdam) records the beat-to-beat finger pulse contour and has been recommended for research studies assessing shortterm changes of blood pressure and its variability. Variability measured in the frequency domain using spectral analysis requires that the impact of breathing be restricted to high frequency spectra (> 0.15 Hz) so data from participants needs to be excluded when the breathing impact occurs in the low frequency spectra (0.04 - 0.15 Hz). This study tested whether breathing frequency can be estimated from standard Finometer recordings using either stroke volume oscillation frequency or spectral stroke volume variability maximum scores. Methods: 22 healthy volunteers were tested for 270s in the supine and upright positions. Finometer recorded the finger pulse contour and a respiratory transducer recorded breathing. Stoke volume oscillation frequency was calculated manually while the stroke volume spectral maximums were obtained using the software Cardiovascular Parameter Analysis (Nevrokard Kiauta, Izola, Slovenia). These estimates were compared to the breathing frequency using the Bland-Altman procedures. Results: Stroke volume oscillation frequency estimated breathing frequency to <±10% 95% levels of agreement in both supine (-7.7 to 7.0%) and upright (-6.7 to 5.4%) postures. Stroke volume variability maximum scores did not accurately estimate breathing frequency. Conclusions: Breathing frequency can be accurately derived from standard Finometer recordings using stroke volume oscillations for healthy individuals in both supine and upright postures. The Finometer can function as a standalone instrument in blood pressure variability studies and does not require support equipment to determine breathing frequency.