2 resultados para 24-hour Recall
em Worcester Research and Publications - Worcester Research and Publications - UK
Resumo:
Two of the most frequently used methods of pollen counting on slides from Hirst type traps are evaluated in this paper: the transverse traverse method and the longitudinal traverse method. The study was carried out during June–July 1996 and 1997 on slides from a trap at Worcester, UK. Three pollen types were selected for this purpose: Poaceae, Urticaceae and Quercus. The statistical results show that the daily concentrations followed similar trends (p < 0.01, R-values between 0.78–0.96) with both methods during the two years, although the counts were slightly higher using the longitudinal traverses method. Significant differences were observed, however, when the distribution of the concentrations during 24 hour sampling periods was considered. For more detailed analysis, the daily counts obtained with both methods were correlated with the total number of pollen grains for the taxon over the whole slide, in two different situations: high and low concentrations of pollen in the atmosphere. In the case of high concentrations, the counts for all three taxa with both methods are significantly correlated with the total pollen count. In the samples with low concentrations, the Poaceae and Urticaceae counts with both methods are significantly correlated with the total counts, but none of Quercus counts are. Consideration of the results indicates that both methods give a reasonable approximation to the count derived from the slide as a whole. More studies need be done to explore the comparability of counting methods in order to work towards a Universal Methodology in Aeropalynology.
Resumo:
Background A large epidemic of asthma occurred following a thunderstorm in southern and central England on 24/25 June 1994. A collaborative study group was formed. Objectives To describe the epidemic and the meteorological, aerobiological and other environmental characteristics associated with it. Methods Collation of data from the Meteorological Office, the Pollen Research Unit, the Department of the Environment's Automatic Urban Network, from health surveillance by the Department of Health and the National Poisons Unit, from clinical experience in general practice and hospitals, and from an immunological study of some of the affected cases from north east London. Results The thunderstorm was a Mesoscale Convective System, an unusual and large form of storm with several centres and severe wind gusts. It occurred shortly after the peak grass pollen concentration in the London area. A sudden and extensive epidemic occurred within about an hour affecting possibly several thousand patients. Emergency services were stretched but the epidemic did not last long. Cases had high serum levels of IgE antibody to mixed grass pollen. Conclusion This study supports the view that patients with specific IgE to grass pollen are at risk of thunderstorm-related asthma. The details of the causal pathway from storm to asthma attack are not clear. Case-control and time series studies are being carried out.