4 resultados para spatial frequency
em Universidad de Alicante
Resumo:
Purpose: To compare outcomes of big-bubble deep anterior lamellar keratoplasty (DALK) and penetrating keratoplasty (PK) for macular corneal dystrophy. Design: Prospective, randomized, interventional case series. Methods: Setting: Single hospital. Patients: Eighty-two eyes of 54 patients requiring keratoplasty for the treatment of macular corneal dystrophy without endothelial involvement were included. Main outcome measures: Operative complications, uncorrected visual acuity, best-corrected visual acuity, contrast sensitivity function, higher-order aberrations, and endothelial cell density were evaluated. Results: The DALK and PK group consisted of 35 and 41 eyes, respectively. Best-corrected visual acuity after surgery was 20/40 or better 68.5% and 70.7% of the eyes in the DALK and PK groups, respectively (P > .05). No statistically significant differences between groups were found in contrast sensitivity function with and without glare for any spatial frequency (P > .05). Significantly higher levels of higher-order aberrations were found in the DALK group (P < .01). In both groups, a progressive and statistically significant reduction in endothelial cell density was found (P < .01). At the last follow-up, the mean endothelial cell loss was 18.1% and 26.9% in DALK and PK groups, respectively (P = .03). Graft rejection episodes were seen in 5 eyes (12.1%) in the PK group, and regrafting was necessary in 3 eyes (7.3%). Recurrence of the disease was documented in 5.7% and 4.8% of the eyes in the DALK and PK groups, respectively. Conclusions: Deep anterior lamellar keratoplasty with the big-bubble technique provided comparable visual and optical results as PK and resulted in less endothelial damage, as well as eliminating endothelial rejection in macular corneal dystrophy. Deep anterior lamellar keratoplasty surgery is a viable option for macular corneal dystrophy without endothelial involvement.
Resumo:
Purpose: The P23H rhodopsin mutation is an autosomal dominant cause of retinitis pigmentosa (RP). The degeneration can be tracked using different anatomical and functional methods. In our case, we evaluated the anatomical changes using Spectral-Domain Optical Coherence Tomography (SD-OCT) and correlated the findings with retinal thickness values determined by immunocytochemistry.Methods: Pigmented rats heterozygous for the P23H mutation, with ages between P18 and P180 were studied. Function was assessed by means of optomotor testing and ERGs. Retinal thicknesses measurements, autofluorescence and fluorescein angiography were performed using Spectralis OCT. Retinas were studied by means of immunohistochemistry. Results: Between P30 and P180, visual acuity decreased from 0.500 to 0.182 cycles per degree (cyc/deg) and contrast sensitivity decreased from 54.56 to 2.98 for a spatial frequency of 0.089 cyc/deg. Only cone-driven b-wave responses reached developmental maturity. Flicker fusions were also comparable at P29 (42 Hz). Double flash-isolated rod-driven responses were already affected at P29. Photopic responses revealed deterioration after P29.A reduction in retinal thicknesses and morphological modifications were seen in OCT sections. Statistically significant differences were found in all evaluated thicknesses. Autofluorescence was seen in P23H rats as sparse dots. Immunocytochemistry showed a progressive decrease in the outer nuclear layer (ONL), and morphological changes. Although anatomical thickness measures were significantly lower than OCT values, there was a very strong correlation between the values measured by both techniques.Conclusions: In pigmented P23H rats, a progressive deterioration occurs in both retinal function and anatomy. Anatomical changes can be effectively evaluated using SD-OCT and immunocytochemistry, with a good correlation between their values, thus making SD-OCT an important tool for research in retinal degeneration.
Resumo:
Analysis of vibrations and displacements is a hot topic in structural engineering. Although there is a wide variety of methods for vibration analysis, direct measurement of displacements in the mid and high frequency range is not well solved and accurate devices tend to be very expensive. Low-cost systems can be achieved by applying adequate image processing algorithms. In this paper, we propose the use of a commercial pocket digital camera, which is able to register more than 420 frames per second (fps) at low resolution, for accurate measuring of small vibrations and displacements. The method is based on tracking elliptical targets with sub-pixel accuracy. Our proposal is demonstrated at a 10 m distance with a spatial resolution of 0.15 mm. A practical application over a simple structure is given, and the main parameters of an attenuated movement of a steel column after an impulsive impact are determined with a spatial accuracy of 4 µm.
Resumo:
Analysis of vibrations and displacements is a hot topic in structural engineering. Although there is a wide variety of methods for vibration analysis, direct measurement of displacements in the mid and high frequency range is not well solved and accurate devices tend to be very expensive. Low-cost systems can be achieved by applying adequate image processing algorithms. In this paper, we propose the use of a commercial pocket digital camera, which is able to register more than 420 frames per second (fps) at low resolution, for accurate measuring of small vibrations and displacements. The method is based on tracking elliptical targets with sub-pixel accuracy. Our proposal is demonstrated at a 10 m distance with a spatial resolution of 0.15 mm. A practical application over a simple structure is given, and the main parameters of an attenuated movement of a steel column after an impulsive impact are determined with a spatial accuracy of 4 µm.