3 resultados para previous residence

em Universidad de Alicante


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To calculate theoretically the errors in the estimation of corneal power when using the keratometric index (nk) in eyes that underwent laser refractive surgery for the correction of myopia and to define and validate clinically an algorithm for minimizing such errors. Methods: Differences between corneal power estimation by using the classical nk and by using the Gaussian equation in eyes that underwent laser myopic refractive surgery were simulated and evaluated theoretically. Additionally, an adjusted keratometric index (nkadj) model dependent on r1c was developed for minimizing these differences. The model was validated clinically by retrospectively using the data from 32 myopic eyes [range, −1.00 to −6.00 diopters (D)] that had undergone laser in situ keratomileusis using a solid-state laser platform. The agreement between Gaussian (PGaussc) and adjusted keratometric (Pkadj) corneal powers in such eyes was evaluated. Results: It was found that overestimations of corneal power up to 3.5 D were possible for nk = 1.3375 according to our simulations. The nk value to avoid the keratometric error ranged between 1.2984 and 1.3297. The following nkadj models were obtained: nkadj= −0.0064286r1c + 1.37688 (Gullstrand eye model) and nkadj = −0.0063804r1c + 1.37806 (Le Grand). The mean difference between Pkadj and PGaussc was 0.00 D, with limits of agreement of −0.45 and +0.46 D. This difference correlated significantly with the posterior corneal radius (r = −0.94, P < 0.01). Conclusions: The use of a single nk for estimating the corneal power in eyes that underwent a laser myopic refractive surgery can lead to significant errors. These errors can be minimized by using a variable nk dependent on r1c.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case report reports the visual rehabilitation obtained with the fitting of a new design of full scleral contact lens (ICD 16.5 contact lens, Paragon Vision Sciences, distributed by Lenticon, Madrid, Spain) in a cornea with advanced keratoconus and previous implantation of intracorneal ring segment with a very limited effect. This eye had a refraction of –3.00 × 55° cylinder, providing a visual acuity of 0.5 LogMAR. The topographic pattern was very irregular with the presence of a significant central protrusion and a significant central corneal thinning. Some previous unsuccessful fittings have been performed with corneal and corneal-scleral lenses. A comfortable wearing was achieved with a fully scleral contact lens of 4600 μm of sagittal height, optical power of –11.25 D, and providing an apical clearance of 196 μm. A visual acuity of 0.0 LogMAR combined with a relevant aberrometric improvement was achieved with this contact lens. The patient was completely satisfied with the fitting. The result was maintained during 1 year after the fitting. Full scleral lenses are then able to provide comfortable wear and a significant increase in visual acuity combined with a significant improvement in the visual quality in eyes with advanced keratoconus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To validate clinically a new method for estimating the corneal power (P,) using a variable keratometric index (nkadj) in eyes with previous laser refractive surgery. Setting. University of Alicante and Medimar International Hospital (Oftalmar), Alicante, (Spain). Design. Retrospective case series. Methods. This retrospective study comprised 62 eyes of 62 patients that had undergone myopic LASIK surgery. An algorithm for the calculation of 11kadj was used for the estimation of the adjusted keratometric corneal power (Pkadj). This value was compared with the classical keratometric corneal power (Pk), the True Net Power (TNP), and the Gaussian corneal power (PcGauss). Likewise, Pkadj was compared with other previously described methods. Results. Differences between PcGauss and P, values obtained with all methods evaluated were statistically significant (p < 0.01). Differences between Pkadj and PcGauss were in the limit of clinical significance (p < 0.01, loA [ - 0.33,0.60] D). Differences between Pkadj and TNP were not statistically and clinically significant (p = 0.319, loA [- 0.50,0.44] D). Differences between Pkadj and previously described methods were statistically significant (p < 0.01), except with PcHaigisL (p = 0.09, loA [ - 0.37,0.29] D). Conclusion. The use of the adjusted keratometric index (nkadj) is a valid method to estimate the central corneal power in corneas with previous myopic laser refractive surgery, providing results comparable to PcHaigisL.