4 resultados para haptic grasp

em Universidad de Alicante


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The center of our Galaxy hosts a supermassive black hole, Sagittarius (Sgr) A∗. Young, massive stars within 0.5 pc of Sgr A∗ are evidence of an episode of intense star formation near the black hole a few million years ago, which might have left behind a young neutron star traveling deep into Sgr A∗’s gravitational potential. On 2013 April 25, a short X-ray burst was observed from the direction of the Galactic center. With a series of observations with the Chandra and the Swift satellites, we pinpoint the associated magnetar at an angular distance of 2.4±0.3 arcsec from Sgr A∗, and refine the source spin period and its derivative (P = 3.7635537(2) s and ˙ P = 6.61(4) × 10−12 s s−1), confirmed by quasi simultaneous radio observations performed with the Green Bank Telescope and Parkes Radio Telescope, which also constrain a dispersion measure of DM = 1750 ± 50 pc cm−3, the highest ever observed for a radio pulsar. We have found that this X-ray source is a young magnetar at ≈0.07–2 pc from Sgr A∗. Simulations of its possible motion around Sgr A∗ show that it is likely (∼90% probability) in a bound orbit around the black hole. The radiation front produced by the past activity from the magnetar passing through the molecular clouds surrounding the Galactic center region might be responsible for a large fraction of the light echoes observed in the Fe fluorescence features.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate and compare the visual, refractive, contrast sensitivity, and aberrometric outcomes with a diffractive bifocal and trifocal intraocular lens (IOL) of the same material and haptic design. METHODS: Sixty eyes of 30 patients undergoing bilateral cataract surgery were enrolled and randomly assigned to one of two groups: the bifocal group, including 30 eyes implanted with the bifocal diffractive IOL AT LISA 801 (Carl Zeiss Meditec, Jena, Germany), and the trifocal group, including eyes implanted with the trifocal diffractive IOL AT LISA tri 839 MP (Carl Zeiss Meditec). Analysis of visual and refractive outcomes, contrast sensitivity, ocular aberrations (OPD-Scan III; Nidek, Inc., Gagamori, Japan), and defocus curve were performed during a 3-month follow-up period. RESULTS: No statistically significant differences between groups were found in 3-month postoperative uncorrected and corrected distance visual acuity (P > .21). However, uncorrected, corrected, and distance-corrected near and intermediate visual acuities were significantly better in the trifocal group (P < .01). No significant differences between groups were found in postoperative spherical equivalent (P = .22). In the binocular defocus curve, the visual acuity was significantly better for defocus of -0.50 to -1.50 diopters in the trifocal group (P < .04) and -3.50 to -4.00 diopters in the bifocal group (P < .03). No statistically significant differences were found between groups in most of the postoperative corneal, internal, and ocular aberrations (P > .31), and in contrast sensitivity for most frequencies analyzed (P > .15). CONCLUSIONS: Trifocal diffractive IOLs provide significantly better intermediate vision over bifocal IOLs, with equivalent postoperative levels of visual and ocular optical quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During grasping and intelligent robotic manipulation tasks, the camera position relative to the scene changes dramatically because the robot is moving to adapt its path and correctly grasp objects. This is because the camera is mounted at the robot effector. For this reason, in this type of environment, a visual recognition system must be implemented to recognize and “automatically and autonomously” obtain the positions of objects in the scene. Furthermore, in industrial environments, all objects that are manipulated by robots are made of the same material and cannot be differentiated by features such as texture or color. In this work, first, a study and analysis of 3D recognition descriptors has been completed for application in these environments. Second, a visual recognition system designed from specific distributed client-server architecture has been proposed to be applied in the recognition process of industrial objects without these appearance features. Our system has been implemented to overcome problems of recognition when the objects can only be recognized by geometric shape and the simplicity of shapes could create ambiguity. Finally, some real tests are performed and illustrated to verify the satisfactory performance of the proposed system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study focuses on how prospective teachers learn about students’ mathematical thinking when (i) anticipating secondary students’ answers reflecting different characteristics of understanding and (ii) propose new activities in relation to the classification of quadrilaterals. The data were collected from forty-eight prospective secondary school teachers enrolled in an initial training programme. The results indicate three changes in how the prospective teachers anticipate secondary students’ answers in relation to the role given to a perceptual or relational perspective of the classification of quadrilaterals. These changes are described considering how prospective teachers grasp the students’ understanding of the inclusive relation among quadrilaterals as a conceptual advance. We argue that prospective teachers’ learning was promoted after participating in a structured environment where they had the opportunity to discuss how to recognize the features of student’s understanding.