3 resultados para dynamic performance appraisal
em Universidad de Alicante
Resumo:
Static stretching prior to sport has been shown to decrease force production in comparison to the increasing popularity of dynamic warm-up methods. However some athletes continue to use a bout of static stretching following dynamic methods. The purpose of this study was to investigate the effects on speed, agility and power following a period of additional static stretching following a dynamic warm-up routine. Twenty-five male University students who participated in team sports performed two warm-up protocols concentrating on the lower body one week apart through a randomised cross over design. The dynamic warm-up (DW) protocol used a series of specific progressive exercises lasting 10 minutes over a distance of 20m. The dynamic warm-up plus static stretching (DWS) protocol used the same DW protocol followed by a 5 minute period during which 7 muscle groups were stretched. Following each warm-up the subjects performed a countermovement vertical jump, 20m sprint and Illinois agility test, 1 minute apart. The results demonstrated no significant differences in speed, agility and jump performance following the two protocols DW and DWS. The study concludes that performing static stretching following a dynamic warm-up prior to performance does not significantly affect speed, agility and vertical jump performance.
Resumo:
In this work, batch and dynamic adsorption tests are coupled for an accurate evaluation of CO2 adsorption performance for three different activated carbons obtained from olives stones by chemical activation followed by physical activation with CO2 at varying times, i.e. 20, 40 and 60 h. Kinetic and thermodynamic CO2 adsorption tests from simulated flue-gas at different temperature and CO2 pressure are carried out both in batch (a manometric equipment operating with pure CO2) and dynamic (a lab-scale fixed-bed column operating with CO2/N2 mixture) conditions. The textural characterization of the activated carbon samples shows a direct dependence of both micropore and ultramicropore volume on the activation time, hence AC60 has the higher contribution. The adsorption tests conducted at 273 and 293 K showed that, when CO2 pressure is lower than 0.3 bar, the lower the activation time the higher CO2 adsorption capacity and a ranking ωeq(AC20)>ωeq(AC40)>ωeq(AC60) can be exactly defined when T= 293 K. This result can be likely ascribed to a narrower pore size distribution of the AC20 sample, whose smaller pores are more effective for CO2 capture at higher temperature and lower CO2 pressure, the latter representing operating conditions of major interest for decarbonation of a flue-gas effluent. Moreover, the experimental results obtained from dynamic tests confirm the results derived from the batch tests in terms of CO2 adsorption capacity. It is important to highlight that the adsorption of N2 on the synthesized AC samples can be considered negligible. Finally, the importance of a proper analysis of characterization data and adsorption experimental results is highlighted for a correct assessment of CO2 removal performances of activated carbons at different CO2 pressure and operating temperature.
Resumo:
This paper presents a new dynamic visual control system for redundant robots with chaos compensation. In order to implement the visual servoing system, a new architecture is proposed that improves the system maintainability and traceability. Furthermore, high performance is obtained as a result of parallel execution of the different tasks that compose the architecture. The control component of the architecture implements a new visual servoing technique for resolving the redundancy at the acceleration level in order to guarantee the correct motion of both end-effector and joints. The controller generates the required torques for the tracking of image trajectories. However, in order to guarantee the applicability of this technique, a repetitive path tracked by the robot-end must produce a periodic joint motion. A chaos controller is integrated in the visual servoing system and the correct performance is observed in low and high velocities. Furthermore, a method to adjust the chaos controller is proposed and validated using a real three-link robot.