5 resultados para disposable contact lenses
em Universidad de Alicante
Resumo:
Background: The aim was to evaluate the visual performance achieved with a new multifocal hybrid contact lens and to compare it with that obtained with two other currently available multifocal soft contact lenses. Methods: This pilot prospective comparative study comprised a total of 16 presbyopic eyes of eight patients ranging in age from 43 to 58 years. All patients were fitted with three different models of multifocal contact lens: Duette multifocal (SynergEyes), Air Optix AQUA multifocal (Alcon) and Biofinity multifocal (CooperVision). Fittings were performed randomly in each patient according to a random number sequence, with a wash-out period between fittings of seven days. At two weeks post-fitting, visual, photopic contrast sensitivity and ocular aberrometry were evaluated. Results: No statistically significant differences were found in distance and near visual acuity achieved with the three different types of multifocal contact lens (p ≥ 0.05). Likewise, no significant differences between lenses were found in the monocular and binocular defocus curve (p ≥ 0.10). Concerning contrast sensitivity, better monocular contrast sensitivities for 6, 12 and 18 cycles per degree were found with the Duette and Air Optix multifocal compared to Biofinity (p = 0.02). Binocularly, differences between lenses were not significant (p ≥ 0.27). Furthermore, trefoil aberration was significantly higher with Biofinity multifocal (p < 0.01) and Air Optix (p = 0.01) multifocal compared to Duette. Conclusions: The Duette multifocal hybrid contact lens seems to provide similar visual quality outcomes in presbyopic patients with low corneal astigmatism, when compared with other soft multifocal contact lenses. This preliminary result should be confirmed in studies with larger samples.
Reverse Geometry Hybrid Contact Lens Fitting in a Case of Donor-Host Misalignment after Keratoplasty
Resumo:
Purpose: To report the successful outcome obtained after fitting a new hybrid contact lens in a cornea with an area of donor-host misalignment and significant levels of irregular astigmatism after penetrating keratoplasty (PKP). Materials and methods: A 41-year-old female with bilateral asymmetric keratoconus underwent PKP in her left eye due to the advanced status of the disease. One year after surgery, the patient referred a poor visual acuity and quality in this eye. The fitting of different types of rigid gas permeable contact lenses was performed, but with an unsuccessful outcome due to contact lens stability problems and uncomfortable wear. Scheimpflug imaging evaluation revealed that a donor-host misalignment was present at the nasal area. Contact lens fitting with a reverse geometry hybrid contact lens (Clearkone, SynergEyes Carlsbad) was then fitted. Visual, refractive, and ocular aberrometric outcomes were evaluated during a 1-year period after the fitting. Results: Uncorrected distance visual acuity improved from a prefitting value of 20/200 to a best corrected postfitting value of 20/20. Prefitting manifest refraction was +5.00 sphere and -5.50 cylinder at 75°, with a corrected distance visual acuity of 20/30. Higher order root mean square (RMS) for a 5 mm pupil changed from a prefitting value of 6.83 µm to a postfitting value of 1.57 µm (5 mm pupil). The contact lens wearing was referred as comfortable, with no anterior segment alterations. Conclusion: The SynergEyes Clearkone contact lens seems to be another potentially useful option for the visual rehabilitation after PKP, especially in cases of donor-host misalignment.
Resumo:
This case report reports the visual rehabilitation obtained with the fitting of a new design of full scleral contact lens (ICD 16.5 contact lens, Paragon Vision Sciences, distributed by Lenticon, Madrid, Spain) in a cornea with advanced keratoconus and previous implantation of intracorneal ring segment with a very limited effect. This eye had a refraction of –3.00 × 55° cylinder, providing a visual acuity of 0.5 LogMAR. The topographic pattern was very irregular with the presence of a significant central protrusion and a significant central corneal thinning. Some previous unsuccessful fittings have been performed with corneal and corneal-scleral lenses. A comfortable wearing was achieved with a fully scleral contact lens of 4600 μm of sagittal height, optical power of –11.25 D, and providing an apical clearance of 196 μm. A visual acuity of 0.0 LogMAR combined with a relevant aberrometric improvement was achieved with this contact lens. The patient was completely satisfied with the fitting. The result was maintained during 1 year after the fitting. Full scleral lenses are then able to provide comfortable wear and a significant increase in visual acuity combined with a significant improvement in the visual quality in eyes with advanced keratoconus.
Resumo:
Fundamentos: El elevado número de personas que trabajando con ordenador utiliza lentes de contacto plantea la cuestión sobre si la suma de estos dos factores de riesgo para la salud visual puede originar un agravamiento del Síndrome Visual Informático. El objetivo de esta revisión es sintetizar el conocimiento científico sobre las alteraciones oculares y visuales relacionadas con la exposición a ordenador en usuarios de lentes de contacto. Métodos: Revisión de artículos científicos (2003-2013) en español e inglés, realizando una búsqueda bibliográfica, en Medline a través de PubMed y en Scopus. Resultados: La búsqueda inicial aportó 114 trabajos, después de aplicar criterios de inclusión/exclusión se incluyeron seis artículos. Todos ellos ponen de manifiesto que las alteraciones al utilizar el ordenador son más frecuentes en las personas usuarias de lentes de contacto, con prevalencias que oscilan de 95,0% al 16,9% que en las que no utilizan lentes de contacto, cuya prevalencia va del 57,5% al 9,9% y con una probabilidad cuatro veces mayor de padecer ojo seco [OR: 4,07 (IC 95%: 3,52-4,71)]. Conclusiones: Las personas usuarias de ordenador padecen más alteraciones oculares y visuales cuando además son usuarias de lentes de contacto, pero los estudios son escasos y poco contundentes. Se precisan nuevas investigaciones que analicen la influencia según los tipos de lentes y sus condiciones de uso, tanto en la sintomatología como en la calidad de la lágrima y la superficie ocular. Las lentes de hidrogel de silicona son las que se asocian a mayor confort.
Resumo:
Purpose: To evaluate and characterize the clinical profile of young asymptomatic or minimally symptomatic patients without diagnosis of dry eye but showing signs compatible with dry eye syndrome (DES). Methods: Prospective study including a total of 50 consecutive subjects with ages ranging from 18 to 40 years that were identified as asymptomatic or minimally symptomatic by means of the Ocular Surface Disease Index (OSDI) (score of <22). In all patients, a complete battery of tests for the diagnosis of DES was performed including the evaluation of the tear film break-up time (TFBUT), the level of corneal and conjunctival staining, and the eyelid and Meibomian morphology. Results: The OSDI score was significantly higher in women than in men (median: 12.5 vs. 5.3, P=0.01). Low grades of ocular surface staining, dysfunction of Meibomian gland expression, and alteration of quality of Meibomian secretions were observed in 56%, 58%, and 84% of eyes, respectively. More eyes with some dysfunction of Meibomian gland expressibility had a TFBUT less than 5 sec (P=0.033). A statistically significant difference in the OSDI score was found between patients with and without systemic allergies (P=0.036) and between male and female (P=0.01). Likewise, the OSDI score was significantly higher in those women wearing contact lenses compared with those not wearing them (P=0.012). Conclusions: Asymptomatic or minimally symptomatic young subjects may present low grades of clinical signs compatible with DES, with a trend to more symptomatology in women and allergic patients. These outcomes should be confirmed in future studies with larger samples.