15 resultados para Wastewater treatment plant

em Universidad de Alicante


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Of all the costs associated with the operation and maintenance of wastewater treatment plants (WWTPs), those associated with energy use tend to be the most significant. From this point of view, it is hence logical that energy efficiency and saving strategies should be one of the current focuses of debate amongst those involved with the management of WWTPs. The present study's objective is to determine the correlation between size and energy consumption for a WWTP. To this end, 90 WWTPs currently in service were analysed and their energetic impact quantified in terms of kWh/m3 of water treated. The results obtained demonstrate that energy consumption ratio increases as the size of WWTPs decreases, either in terms of treatment volume or population equivalent served.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The siloxanes present in the biogas produced during anaerobic digestion damage the mechanism of cogeneration equipment and, consequently, negatively affect the energy valorization process. For this reason, the detection and elimination of these silicon-derived chemical compounds are a priority in the management of cogeneration facilities. In this regard, the objectives of this paper are, firstly, to characterize the siloxanes in the biogas and, secondly, to qualitatively evaluate the influence of the dose of iron chloride on its elimination. The research was performed at the Rincón de León Wastewater Treatment Plant (Alicante, Spain). The outflow biogas of the digesters and of the pressurized gasometers was sampled and analyzed. The results obtained made it possible to demonstrate, firstly, the absence of linear siloxanes and that, of the cyclic siloxanes, the predominant type was decamethylcyclopentasiloxane, and, secondly, that the addition of iron chloride in the digesters significantly reduces the siloxane content in the biogas. Additionally, it was demonstrated that the process of compression of the biogas, with the elimination of condensates, also produces significant reductions in the concentration of siloxanes in the biogas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To study the possibility of producing better water quality from municipal wastewater, a membrane bioreactor (MBR) pilot plant with flat sheet (FS) and hollow fiber (HF) membranes coupled with another pilot plant equipped with nanofiltration (NF)/reverse osmosis (RO) membranes were operated to treat municipal wastewater from the wastewater treatment plant (WWTP) Rincón de León, Alicante (Spain). This study was focused on improving the quality of the permeate obtained from the MBR process when complemented by NF or RO stages with respect to salinity, organic matter and nutrients. Furthermore, the removal efficiencies of 10 EMPs were evaluated, comparing the reductions achieved between the wastewater treatment by MBR (adsorption to sludge and biodegradation) and the later treatment using NF or RO (mainly size exclusion). The results showed that the high quality of water was obtained which is appropriate for reuse with salinity removal efficiencies higher than 97%, 96% for total organic carbon (TOC), 91% for nitrates View the MathML sourceNO3- and 99% for total phosphorous (TP). High removal efficiencies were obtained for the majority of the analyzed EMP compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gaseous emissions are an important problem in municipal solid waste (MSW) treatment plants. The sources points of emissions considered in the present work are: fresh compost, mature compost, landfill leaks and leachate ponds. Hydrogen sulphide, ammonia and volatile organic compounds (VOCs) were analysed in the emissions from these sources. Hydrogen sulphide and ammonia were important contributors to the total emission volume. Landfill leaks are significant source points of emissions of H2S; the average concentration of H2S in biogas from the landfill leaks is around 1700 ppmv. The fresh composting site was also an important contributor of H2S to the total emission volume; its concentration varied between 3.2 and 1.7 ppmv and a decrease with time was observed. The mature composting site showed a reduction of H2S concentration (<0.1 ppmv). Leachate pond showed a low concentration of H2S (in order of ppbv). Regarding NH3, composting sites and landfill leaks are notable source points of emissions (composting sites varied around 30–600 ppmv; biogas from landfill leaks varied from 160 to 640 ppmv). Regarding VOCs, the main compounds were: limonene, p-cymene, pinene, cyclohexane, reaching concentrations around 0.2–4.3 ppmv. H2S/NH3, limonene/p-cymene, limonene/cyclohexane ratios can be useful for analysing and identifying the emission sources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The growing economic and environmental importance of managing water resources at a global level also entails greater efforts and interest in improving the functioning and efficiency of the increasingly more numerous wastewater treatment plants (WWTPs). In this context, this study analyzes the efficiency of a uniform sample of plants of this type located in the region of Valencia (Spain). The type of efficiency measure used for this (conditional order-m efficiency) allows continuous and discrete contextual variables to be directly involved in the analysis and enables the assessment of their statistical significance and effect (positive or negative). The main findings of the study showed that the quality of the influent water and also the size and age of the plants had a significant influence on their efficiency levels. In particular, as regards the effect of such variables, the findings pointed to the existence of an inverse relationship between the quality of the influent water and the efficiency of the WWTPs. Also, a lower annual volume of treated water and more modern installations showed a positive influence. Additionally, the average efficiency levels observed turned out to be higher than those reported in previous studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study wastewater treatment plant (WWTP) sludge was subjected to a reactive pyrolysis treatment to produce a high quality pyro-oil. Sludge was treated in supercritical conditions in the presence of methanol using hexane as cosolvent in a high pressure lab-autoclave. The variables affecting the pyro-oil yield and the product quality, such as mass ratio of alcohol to sludge, presence of cosolvent and temperature, were investigated. It was found that the use of a non-polar cosolvent (hexane) presents advantages in the production of high quality pyro-oil from sludge: increase of the non-polar pyro-oil yield and a considerable reduction of the amount of methanol needed to carry out the transesterification of fatty acids present in the sludge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes an effective procedure for reducing the water content of excess sludge production from a wastewater treatment plant by increasing its concentration and, as a consequence, minimizing the volume of sludge to be managed. It consists of a pre-dewatering sludge process, which is used as a preliminary step or alternative to the thickening. It is made up of two discontinuous sequential stages: the first is resettling and the second, filtration through a porous medium. The process is strictly physical, without any chemical additives or electromechanical equipment intervening. The experiment was carried out in a pilot-scale system, consisting of a column of sedimentation that incorporates a filter medium. Different sludge heights were tested over the filter to verify the influence of hydrostatic pressure on the various final concentrations of each stage. The results show that the initial sludge concentration may increase by more than 570% by the end of the process with the final volume of sludge being reduced in similar proportions and hydrostatic pressure having a limited effect on this final concentration. Moreover, the value of the hydrostatic pressure at which critical specific cake resistance is reached is established.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Haloferax mediterranei is a denitrifying halophilic archaeon able to reduce nitrate and nitrite under oxic and anoxic conditions. In the presence of oxygen, nitrate and nitrite are used as nitrogen sources for growth. Under oxygen scarcity,this haloarchaeon uses both ions as electron acceptors via a denitrification pathway. In the present work, the maximal nitriteconcentration tolerated by this organism was determined by studying the growth of H. mediterranei in minimal medium containing30, 40 and 50 mM nitrite as sole nitrogen source and under initial oxic conditions at 42 °C. The results showed theability of H. mediterranei to withstand nitrite concentrations up to 50 mM. At the beginning of the incubation, nitrate wasdetected in the medium, probably due to the spontaneous oxidation of nitrite under the initial oxic conditions. The completeremoval of nitrite and nitrate was accomplished in most of the tested conditions, except in culture medium containing 50 mMnitrite, suggesting that this concentration compromised the denitrification capacity of the cells. Nitrite and nitrate reductases activities were analyzed at different growth stages of H. mediterranei. In all cases, the activities of the respiratory enzymeswere higher than their assimilative counterparts; this was especially the case for NirK. The denitrifying and possibly detoxifyingrole of this enzyme might explain the high nitrite tolerance of H. mediterranei. This archaeon was also able to remove60 % of the nitrate and 75 % of the nitrite initially present in brine samples collected from a wastewater treatment facility.These results suggest that H. mediterranei, and probably other halophilic denitrifying Archaea, are suitable candidates for thebioremediation of brines with high nitrite and nitrate concentrations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The pyrolysis of a sludge produced in the waste water treatment plant of an oil refinery was studied in a pilot plant reactor provided with a system for condensation of semivolatile matter. The study comprises experiments at 350, 400, 470 and 530 °C in nitrogen atmosphere. Analysis of all the products obtained (gases, liquids and chars) are presented, with a thermogravimetric study of the char produced and analysis of main components of the liquid. In the temperature range studied, the composition of the gas fraction does not appreciably vary. In the liquids, the light hidrocarbon yield increases with increasing temperature, whereas the aromatic compounds diminish. The decomposition of the solid fraction has been analysed, finding a material that reacts rapidly with oxygen regardless of the conditions it is formed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Given the complex structure of electricity tariffs and their steady growth in Spanish, we've studied its effect over the operating costs of the wastewater treatment plants (WWTP), concluding that in the last three years the revisions of electricity rates have meant increases in electricity costs of 64.5% in the rate 3.1.A and 79.1% in the rate 6.1. This has caused the cost of electricity, which was the most important, has increased from a 44% of total operating costs in the year 2009, to more than a 56% in the year 2012.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Se ha utilizado una planta de tratamiento a escala laboratorio consiste en un biorreactor de membrana (MBR). Esta planta está compuesta por un reactor biológico de 25 L de capacidad. Se utilizó una membrana plana de micro filtración marca Kubota de polietileno clorado, tamaño de poro 0,1 μm y área de filtración 0.116 m2. Se utilizaron como condiciones de operación: tiempo de residencia hidráulico 3 días, caudal de permeado 0.35 L/h y LMH 3 L/m2h. Se ha podido comprobar que es posible adaptar una población microbiológica a las particulares características químicas del lixiviado procedente de la planta y tratar estos lixiviados en un reactor biológico de membrana sumergida operando en condiciones habituales de sólidos en suspensión en el reactor entre 8-12 g/L durante un periodo de 6 meses. El proceso utilizado permite reducir la materia orgánica (97% DBO5 y 40% DQO) presente en estas corrientes residuales, agotando prácticamente toda la materia biodegradable. Respecto a los contenidos de nutrientes, el tratamiento MBR ensayado permite reducir de 35-40% el nitrógeno total, 45-50% el nitrógeno amoniacal y un 65-70% el fósforo total. Los sólidos en suspensión se han reducido en el efluente tratado en más de un 99%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This research paper deals with the evolution of the extracellular polymeric substances (EPS) produced in the mixed liquor of two 25 L bench-scale membrane bioreactors (MBRs), with micro (MF-MBR) and ultrafiltration (UF-MBR) submerged membranes. The conclusion focuses on the relationship between the operation and how EPS respond, demonstrating that significant changes in EPS concentration were commonly observed when abrupt changes in the operational conditions took place. Bound EPS (EPSb) showed moderate positive statistical correlations with sludge age and MLSS for the two MBRs. Soluble EPS (EPSs), on the other hand, showed a moderate negative statistical correlation between EPSs with the two parameters analyzed for MF-MBR and no correlation with the UF-MBR was found. With respect to the composition of EPS, EPSb were mostly made up of proteins (44–46%) whereas in EPSs, the three components (proteins, carbohydrates, and humic substances) appeared in approximately the same proportion. The statistical analysis exhibited strong positive correlations between EPSb and their constituents, however for EPSs, the correlation was strong only with carbohydrates and moderate with humic substances.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this study, the filtration process and the biomass characteristics in a laboratory-scale submerged membrane bioreactor (MBR) equipped with a hollow fiber (HF) microfiltration membrane were studied at different solid retention times (SRT). The MBR was fed by synthetic wastewater and the organic loading rate (OLR) was 0.5, 0.2, 0.1, and 0.08 kg COD kg VSS−1 d−1 for 10, 30, 60, and 90 days of SRT, respectively. The hydraulic retention time was 8.4 h and the permeate flux was 6 L m−2 h−1(LMH). Data analysis confirmed that at all the studied SRTs, the HF-MBR operated very good obtaining of high quality permeates. Chemical Oxygen Demand (COD) removal efficiencies were higher than 95%. The best filtration performance was reached at SRT of 30 d. On the other hand, the respirometric analysis showed that biomass was more active and there was more biomass production at low SRTs. The concentration of soluble extracellular polymeric substances (EPS) decreased with increasing SRT. A decrease of soluble EPS caused a decrease of membrane fouling rate, decreasing the frequency of chemical cleanings. The floc size decreased with SRT increasing. At high SRTs, there was more friction among particles due to the increase of the cellular density and the flocs broke decreasing their size.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The remediation of paracetamol (PA), an emerging contaminant frequently found in wastewater treatment plants, has been studied in the low concentration range (0.3–10 mg L−1) using as adsorbent a biomass-derived activated carbon. PA uptake of up to 100 mg g−1 over the activated carbon has been obtained, with the adsorption isotherms being fairly explained by the Langmuir model. The application of Reichemberg and the Vermeulen equations to the batch kinetics experiments allowed estimating homogeneous and heterogeneous diffusion coefficients, reflecting the dependence of diffusion with the surface coverage of PA. A series of rapid small-scale column tests were carried out to determine the breakthrough curves under different operational conditions (temperature, PA concentration, flow rate, bed length). The suitability of the proposed adsorbent for the remediation of PA in fixed-bed adsorption was proven by the high PA adsorption capacity along with the fast adsorption and the reduced height of the mass transfer zone of the columns. We have demonstrated that, thanks to the use of the heterogeneous diffusion coefficient, the proposed mathematical approach for the numerical solution to the mass balance of the column provides a reliable description of the breakthrough profiles and the design parameters, being much more accurate than models based in the classical linear driving force.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Póster presentado en 19th International Congress of Chemical and Process Engineering, Prague, Czech Republic August 28th-September 1st, 2010.