Purpose To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. Methods Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. Results Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = −0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = −0.551, p = 0.04), but not with higher order RMS (r = −0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. Conclusions Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.
Resumo:
Purpose: To evaluate in keratoconus eyes the intrasubject repeatability of anterior and posterior corneal curvature and of other anterior segment anatomic measurements obtained with a new topography system combining Scheimpflug-photography and Placido-disk technology. Setting: Vissum Corporation, Alicante, Spain. Design: Evaluation of technology. Methods: All keratoconus eyes had a comprehensive ophthalmologic examination including analysis with the Sirius system. Three consecutive measurements were obtained to assess the intrasubject repeatability of the following parameters: anterior and posterior corneal curvature and shape factor, white-to-white (WTW) corneal diameter, central and minimum corneal thickness, and anterior chamber depth (ACD). The within-subject standard deviation (Sw) and intraclass correlation coefficient (ICC) were calculated. Results: This study comprised 61 eyes of 61 patients ranging in age from 14 to 64 years. For anterior and posterior corneal curvatures and power vector components, the Sw was 0.29 mm or less in all cases. The ICC was above 0.990 in all cases except the flattest curvature of the posterior corneal surface at 3.0 mm, which was 0.840 (moderate agreement), and the posterior power vector J0, which was 0.665 (poor agreement), 0.752, and 0.758 (moderate agreement) for 3.0 mm, 5.0 mm, and 7.0 mm, respectively. In shape factor measurements, the Sw was 0.12 or less in all cases and the ICC ranged between 0.989 and 0.999. Pachymetry, ACD, and WTW had ICC values very close to 1. Conclusion: The new topography system provided repeatable measurements of corneal shape and other anatomic parameters in eyes with keratoconus.
Resumo:
Póster presentado en el VII European/ I World Meeting in Visual and Physiological Optics
Resumo:
Materials with new visual appearances have emerged over the last few years. In the automotive industry in particular there is a growing interest in materials with new effect finishes, such as metallic, pearlescent, sparkle, and graininess effects. Typically, for solid colours the mean of three measurements with repetitions is sufficient to obtain a representative measurement for colour characterisation. However, gonio-apparent panels have non-homogeneous colours, and there are no studies that recommend the minimum number of repetitions for colour, sparkle, and graininess characterisation of this type of panel. We assume that colour panels incorporating special-effect pigments in their colour recipes will require a higher minimum number of measurements than solid colour panels. Therefore, the purpose of this study is to verify this assumption by using a multiangle BYK-mac spectrophotometer, given that it is currently the only commercial device that can measure colour, sparkle, and graininess values simultaneously. In addition, a possible methodology is given for establishing the minimum number of measurements when characterising gonio-apparent materials using a specific instrument, able to be implemented in future instruments when determining multiple appearance attributes (colour, gloss, sparkle, etc.) for many coloration technologies. Thus, we studied the minimum number of measurements needed to characterise the colour, sparkle, and graininess of three types of sample with solid, metallic, and pearlescent coatings respectively. Twenty measurements were made at twenty random positions (different target areas) of 90 samples. The minimum number of measurements for all these variables was determined on the basis of the point at which the cumulative mean value became constant. Thus, applying new statistical tools, it is clearly shown that metallic and pearlescent panels require more colour measurements than solid panels, in particular when geometries are being measured in a specular direction. As regards texture (sparkle and graininess), more measurements are needed for graininess than for sparkle, and more for metallic panels than for pearlescent panels.