3 resultados para Retaining walls

em Universidad de Alicante


Relevância:

20.00% 20.00%

Publicador:

Resumo:

En este artículo se muestra una aplicación de la microtomografía computerizada de Rayos X (microCT-RX) como técnica no destructiva útil para la caracterización del interior de estructuras sin necesidad de perder la muestra. Gracias a la sensibilidad de la técnica ha sido posible distinguir diferentes tipos de crecimiento espeleotémico dentro de una estalactita localizada en las bóvedas interiores de la muralla histórica de la isla de Nueva Tabarca.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

San Roque church (Campeche, Mexico) was built at the end of the 17th century with a micritic limestone and lime mortar in baroque style. In 2005 the church exhibited heavy biodeterioration associated with the development of extensive dark green phototrophic-based biofilms. Several cyanobacteria belonging to the order Chroococcales and lichenized fungi (Toninia nordlandica, Lobaria quercizans, Lecanora subcarnea, Cystocoleus ebeneus) were predominant in the dark biofilm samples, as revealed by DNA-based molecular techniques. In 2009, a cleaning and restoration intervention was adopted; however, after few months, microbial recolonization started to be noticeable on the painted church walls, representing an early phototrophic-based recolonization. According to molecular analysis, scanning electron microscopy observations and digital image analysis of cross sections, new phototrophic-based colonization, composed of cyanobacteria and bryophytes, developed mainly beneath the restored mortars. The intrinsic properties of the mortars, the tropical climate of Campeche and the absence of a biocide treatment in the restoration protocol influenced the recolonization of the church façades and enhanced the overall rate of deterioration in a short-term period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last few decades, the use of cast in situ reinforced concrete sandwich panels for the construction of low- to mid-rise buildings has become more and more widespread due to several interesting properties of this construction technique, such as fast construction and high thermal and acoustic performances. Nonetheless the level of knowledge of the structural behavior of systems made of squat reinforced concrete sandwich panels is still not so consolidated, especially with reference to the seismic response, due to the lack of experimental studies. In recent years, while various experimental tests have been conducted on single panels aimed at assessing their seismic capacity, only few tests have been carried out on more complex structural systems. In this paper, the experimental results of a series of shaking-table tests performed on a full-scale 3-storey building are presented in detail. The main goal is to give to the scientific community the possibility of develop independent interpretation of these experimental results. An in-depth interpretation of the discrepancies between the analytical predictions and the experimental results is beyond the objective of this paper and is still under development. Nonetheless, preliminary interpretations indicate that both the stiffness and the strength of the building under dynamic excitation appear quite superior with respect to those expected from the results of previous pseudo-static cyclic tests conducted on simple specimens.