7 resultados para Research case study
em Universidad de Alicante
Resumo:
Presentation for the I International Seminar of Tourism and Hospitality Research, Alicante, April 18th, 2016.
Resumo:
The purpose of this paper is to analyze the quasi-elastic deformational behavior that has been induced by groundwater withdrawal of the Tertiary detrital aquifer of Madrid (Spain). The spatial and temporal evolution of ground surface displacement was estimated by processing two datasets of radar satellite images (SAR) using Persistent Scatterer Interferometry (PSI). The first SAR dataset was acquired between April 1992 and November 2000 by ERS-1 and ERS-2 satellites, and the second one by the ENVISAT satellite between August 2002 and September 2010. The spatial distribution of PSI measurements reveals that the magnitude of the displacement increases gradually towards the center of the well field area, where approximately 80 mm of maximum cumulated displacement is registered. The correlation analysis made between displacement and piezometric time series provides a correlation coefficient greater than 85% for all the wells. The elastic and inelastic components of measured displacements were separated, observing that the elastic component is, on average, more than 4 times the inelastic component for the studied period. Moreover, the hysteresis loops on the stress–strain plots indicate that the response is in the elastic range. These results demonstrate the quasi-elastic behavior of the aquifer. During the aquifer recovery phase ground surface uplift almost recovers from the subsidence experienced during the preceding extraction phase. Taking into account this unique aquifer system, a one dimensional elastic model was calibrated in the period 1997–2000. Subsequently, the model was used to predict the ground surface movements during the period 1992–2010. Modeled displacements were validated with PSI displacement measurements, exhibiting an error of 13% on average, related with the inelastic component of deformation occurring as a long-term trend in low permeability fine-grained units. This result further demonstrates the quasi-elastic deformational behavior of this unique aquifer system.
Resumo:
A new methodology is proposed to produce subsidence activity maps based on the geostatistical analysis of persistent scatterer interferometry (PSI) data. PSI displacement measurements are interpolated based on conditional Sequential Gaussian Simulation (SGS) to calculate multiple equiprobable realizations of subsidence. The result from this process is a series of interpolated subsidence values, with an estimation of the spatial variability and a confidence level on the interpolation. These maps complement the PSI displacement map, improving the identification of wide subsiding areas at a regional scale. At a local scale, they can be used to identify buildings susceptible to suffer subsidence related damages. In order to do so, it is necessary to calculate the maximum differential settlement and the maximum angular distortion for each building of the study area. Based on PSI-derived parameters those buildings in which the serviceability limit state has been exceeded, and where in situ forensic analysis should be made, can be automatically identified. This methodology has been tested in the city of Orihuela (SE Spain) for the study of historical buildings damaged during the last two decades by subsidence due to aquifer overexploitation. The qualitative evaluation of the results from the methodology carried out in buildings where damages have been reported shows a success rate of 100%.
Resumo:
Background: Despite the progress made on policies and programmes to strengthen primary health care teams’ response to Intimate Partner Violence, the literature shows that encounters between women exposed to IPV and health-care providers are not always satisfactory, and a number of barriers that prevent individual health-care providers from responding to IPV have been identified. We carried out a realist case study, for which we developed and tested a programme theory that seeks to explain how, why and under which circumstances a primary health care team in Spain learned to respond to IPV. Methods: A realist case study design was chosen to allow for an in-depth exploration of the linkages between context, intervention, mechanisms and outcomes as they happen in their natural setting. The first author collected data at the primary health care center La Virgen (pseudonym) through the review of documents, observation and interviews with health systems’ managers, team members, women patients, and members of external services. The quality of the IPV case management was assessed with the PREMIS tool. Results: This study found that the health care team at La Virgen has managed 1) to engage a number of staff members in actively responding to IPV, 2) to establish good coordination, mutual support and continuous learning processes related to IPV, 3) to establish adequate internal referrals within La Virgen, and 4) to establish good coordination and referral systems with other services. Team and individual level factors have triggered the capacity and interest in creating spaces for team leaning, team work and therapeutic responses to IPV in La Virgen, although individual motivation strongly affected this mechanism. Regional interventions did not trigger individual and/ or team responses but legitimated the workings of motivated professionals. Conclusions: The primary health care team of La Virgen is involved in a continuous learning process, even as participation in the process varies between professionals. This process has been supported, but not caused, by a favourable policy for integration of a health care response to IPV. Specific contextual factors of La Virgen facilitated the uptake of the policy. To some extent, the performance of La Virgen has the potential to shape the IPV learning processes of other primary health care teams in Murcia.
Resumo:
A twenty-year period of severe land subsidence evolution in the Alto Guadalentín Basin (southeast Spain) is monitored using multi-sensor SAR images, processed by advanced differential interferometric synthetic aperture radar (DInSAR) techniques. The SAR images used in this study consist of four datasets acquired by ERS-1/2, ENVISAT, ALOS and COSMO-SkyMed satellites between 1992 and 2012. The integration of ground surface displacement maps retrieved for different time periods allows us to quantify up to 2.50 m of cumulated displacements that occurred between 1992 and 2012 in the Alto Guadalentín Basin. DInSAR results were locally compared with global positioning system (GPS) data available for two continuous stations located in the study area, demonstrating the high consistency of local vertical motion measurements between the two different surveying techniques. An average absolute error of 4.6 ± 4 mm for the ALOS data and of 4.8 ± 3.5 mm for the COSMO-SkyMed data confirmed the reliability of the analysis. The spatial analysis of DInSAR ground surface displacement reveals a direct correlation with the thickness of the compressible alluvial deposits. Detected ground subsidence in the past 20 years is most likely a consequence of a 100–200 m groundwater level drop that has persisted since the 1970s due to the overexploitation of the Alto Guadalentín aquifer system. The negative gradient of the pore pressure is responsible for the extremely slow consolidation of a very thick (> 100 m) layer of fine-grained silt and clay layers with low vertical hydraulic permeability (approximately 50 mm/h) wherein the maximum settlement has still not been reached.
Resumo:
PAS1192-2 (2013) outlines the “fundamental principles of Level 2 information modeling”, one of these principles is the use of what is commonly referred to as a Common Data Environment (CDE). A CDE could be described as an internet-enabled cloudhosting platform, accessible to all construction team members to access shared project information. For the construction sector to achieve increased productivity goals, the next generation of industry professionals will need to be educated in a way that provides them with an appreciation of Building Information Modelling (BIM) working methods, at all levels, including an understanding of how data in a CDE should be structured, managed, shared and published. This presents a challenge for educational institutions in terms of providing a CDE that addresses the requirements set out in PAS1192-2, and mirrors organisational and professional working practices without causing confusion due to over complexity. This paper presents the findings of a two-year study undertaken at Ulster University comparing the use of a leading industry CDE platform with one derived from the in-house Virtual Learning Environment (VLE), for the delivery of a student BIM project. The research methodology employed was a qualitative case study analysis, focusing on observations from the academics involved and feedback from students. The results of the study show advantages for both CDE platforms depending on the learning outcomes required.
Resumo:
A novel polymer electrolyte membrane electrochemical reactor (PEMER) configuration has been employed for the direct electrooxidation of propargyl alcohol (PGA), a model primary alcohol, towards its carboxylic acid derivatives in alkaline medium. The PEMER configuration comprised of an anode and cathode based on nanoparticulate Ni and Pt electrocatalysts, respectively, supported on carbonaceous substrates. The electrooxidation of PGA was performed in 1.0 M NaOH, where a cathode based on a gas diffusion electrode was manufactured for the reduction of oxygen in alkaline conditions. The performance of a novel alkaline anion-exchange membrane based on Chitosan (CS) and Poly(vinyl) alcohol (PVA) in a 50:50 composition ratio doped with a 5 wt.% of poly (4-vinylpyridine) organic ionomer cross-linked, methyl chloride quaternary salt resin (4VP) was assessed as solid polymer electrolyte. The influence of 4VP anionic ionomer loading of 7, 12 and 20 wt.% incorporated into the electrocatalytic layers was examined by SEM and cyclic voltammetry (CV) upon the optimisation of the electroactive area, the mechanical stability and cohesion of the catalytic ink onto the carbonaceous substrate for both electrodes. The performance of the 4VP/CS:PVA membrane was compared with the commercial alkaline anion-exchange membrane FAA −a membrane generally used in direct alcohol alkaline fuel cells- in terms of polarisation plots in alkaline conditions. Furthermore, preparative electrolyses of the electrooxidation of PGA was performed under alkaline conditions of 1 M NaOH at constant current density of 20 mA cm−2 using a PEMER configuration to provide proof of the principle of the feasibility of the electrooxidation of other alcohols in alkaline media. PGA conversion to Z isomers of 3-(2-propynoxy)-2-propenoic acid (Z-PPA) was circa 0.77, with average current efficiency of 0.32. Alkaline stability of the membranes within the PEMER configuration was finally evaluated after the electrooxidation of PGA.